PROPER MATRL WATER SUPPLY PIPE | REMOVE UNAPPROVED FLEXIBLE WATER SUPPLY LINE AT LAVATORY AND TOILET AND THROUGHOUT PREMISES. | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
ALL JUNCTION BOXES SHALL BE READILLY ACCESSIBLE;JUNCTION BOXES AT PANEL LOCATIONS OBSTRUCTUD BY CONDUIT RUNS 14E-3-314.29 | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View | |
INSTALL COVERS | PROVIDE PROPER TYPE COVERS FOR OPEN JUNCTION BOXES WITH EXPOSE WIRING AND JUNCTION BOXES MISSING KNOCK OUT FILLERS THROUGH OUT THE STORE AREAS DANGEROUS AND HAZARDOUS | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE SOIL PIPING | RAW SEWAGE PRESENT IN THE BASEMENT AT THE TIME OF INPECTION. DANGEROUS AND HAZARDOUS | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
SECURE RACEWAY | PROPERLY SUPPORT ALL CONDUIT RUNS AT ELECTRICAL PANEL AREA AND REAR SERVICE RISER NOT SUPPORTED PROPERLY AT REAR EXTERIOR AREA DANGEROUS AND HAZARDOUS CONDITION | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PLUMBING PERMIT. | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
ALL CONDUIT, BOXES, DEVICES AND ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, THROUGH OUT STORE AREAS AND PANEL LOCATIONS.14E-1-110.12 | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View | |
SYSTEM III | PROVIDE SYSTEM 3 EMERGENCY LIGHTS AND EXIT SIGNS THROUGH OUT BASEMENT AREAS | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS AND FOR INSTALLATION OF JUNCTION BOX ON SUPPLY LINE BEFORE THE PANEL AND NEW LED LIGHTS INSTALLED WITHOUT PERMITS.13-12-360 | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View | |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS DANGEROUS AND HAZARDOUS | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN LICENSE PLUMBING CONTRACTOR. | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | PROVIDE ILLUMINATION THROUGH OUT ALL BASEMENT AREAS DANGEROUS AND HAZARDOUS CONDITION | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
SUPPLEMENTAL GROUND | PROVIDE SUPPLEMENTAL GROUND FOR EXTERIOR METER BOX AREA. | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTENSION CORD USE THROUGH OUT LIQUOR STORE AREA AND COUTER AREA. DANGEROUS AND HAZARDOUS. | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR ADDITION BUILT FOR STORAGE NO PLANS OR PERMITS ON FILE REMOVE OR PROVIDE PLANS PERMITS | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
ARMORED CABLE | REPLACE DEFECTIVE AND EXCESSIVE USE OF ARMORED CABLE THROUGH OUT BASEMENT AREAS | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
RMV DFT PIPE,FITTING,FIXTURE | REPLACE FLEXIBLE GAS LINE AT ELEVATED HEATER. MUST BE HARD PIPE WITH BLACK STEEL PIPE. D&H | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
PROVIDE A SWITCH CONTROL LIGHT FOR BATHROOM 14E-5-570.10F | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View | |
REPAIR LINTELS | RUSTED AND DETERIORATING LINTELS AT SOUTH AND EAST ELEVATION.LINTELS OVER 6' REQUIRE PLANS AND PERMITS | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
PROVIDE | VARIOUS AISLES REDUCED BELOW THE REQUIRED 36" MINIMUM 15-4-880 DANGEROUS AND HAZARDOUS | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | OPEN METER BOX WITH EXPOSE LIVE PARTS AT REAR EXTERIOR AREA OF BUILDING. DANGEROUS AND HAZARDOUS | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | THERE IS A TOTAL LACK OF FIRE SEPARATION ON BASEMENT CEILING WITH EXPOSED WOODEN JOIST. UNABLE TO FULLY INSPECT BASEMENT DUE TO RAW SEWAGE. DANGEROUS AND HAZARDOUS | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTORS. DANGEROUS AND HAZARDOUS | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR MASONRY WALL-STEP FRACTURE ABOVE 7632. MISSING SECTION OF LIMESTONE ABOVE LINTELS AT EAST ELEVATION WASHED OUT MORTAR JOINTS ALL ELEVATIONS. | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
JUNCTION BOX IN LINE WITH SERVICE CONDUCTORS TO ELECTRICAL PANEL NOT ALLOWED 14E-2-230-.43 | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View | |
JUNCTION BOXES NOT PROPERLY SIZE AT WINDOW LOCATIONS 14E-3-314.16 | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View | |
OBSTRUCTIONS IN EXIT WAY | REAR EXIT BLOCKED BY STOCK AND ONLY 30".36" DOOR MINIMUM IS REQUIRED. UNABLE TO EXIT SAFELY FROM THE REAR EXIT. THERE IS EXCESSIVE AMOUNTS OF CARDBOARD BOXES IN THE REAR YARD. DANGEROUS AND HAZARDOUS | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAYS | PROVIDE GROUND CONTINUITY FOR CONDUIT APART AT JUNCTION BOX AT WINDOW AREA DANGEROUS AND HAZARDOUS CONDITION | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | REMOVE UNAPPROVED PVC FLEXIBLE DRAIN PIPE AT LAVATORY AND THROUGHOUT PREMISES. | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |
PROVIDE | DOOR TO BATHROOM UNDER SIZED. MUST PROVIDE PROPER DOOR WIDTH TO BATHROOM. MINIMUM 30" DANGEROUS AND HAZARDOUS | 7640 N SHERIDAN RD | COMPLAINT | FAILED | View |