Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | SR#07-02173162- NO OWNERSHIP/MANAGEMENT SIGN POSTED | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT HALLS/STAIR WAY AT TOP-NO SMOKE DETECTOR, 2ND FLOOR FRONT NO DETECTORS | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND FLOOR FRONT NO CARBON MONOXIDE DETECTOR | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | NO HEAT IN BUILDING. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
UNAPPROVED HEATING DEVICE | 1ST FLOOR REAR USING ELECTRIC SPACE HEATER. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | WEST EXTERIOR EGRESS MISSING EXTERIOR PORCH SYSTEM CAUSING A DANGEROUS AND HAZARDOUS CONDITION. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR REAR MISSING SMOKE DETECTORS CAUSING A DANGEROUS AND HAZARDOUS CONDITION. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR REAR MISSING CARBON MONOXIDE DETECTOR CAUSING A DANGEROUS AND HAZARDOUS CONDITION. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | REAR EXTERIOR PORCH IS MISSING. PLANS AND PERMITS REQUIRED TO CONSTRUCT NEW PORCH. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLIES TO LAVATORY, TOILET AND KITCHEN FAUCET, UNITS 1 REAR, 2 REAR, 3 FRONT AND ATTIC UNIT. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
PROVIDE | SAFE PAN WATER HEATER KITCHEN UNIT 2 REAR. (18-29-504.8) | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
KEEP FIXTUR CLEAN AND SANITARY | LAVATORY, TOILET, TUB, KITCHEN SINK UNITS 1 REAR, 2 REAR, 3 REAR, 3 FRONT, ATTIC UNIT. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
PROVIDE | PROVIDE TOILET UNIT 3 REAR. (13-196-350) | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | PERMIT FOR VIOLATIONS. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE AND UNDERSIZED POWER SERVICE. INSTALL MINIMUM 400 AMP POWER SERVICE. BROKEN RISER ON EXTERIOR - DANGEROUS. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
SYSTEM III | INSTALL EMERGENCY LIGHTING SYSTEM III AT ALL LEVELS. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
EXPOSED WIRING | REMOVE EXPOSED WIRING THROUGHOUT UNITS AND STAIRWELLS AND EXTERIOR - DANGEROUS. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO ALL EXTERIOR ENTRY DOORS AND STAIRWELLS INCLUDING ATTIC. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
(18-27-210.8) INSTALL GFCI'S TO WET LOCATIONS, KITCHENS AND BATHROOMS IN ALL UNITS. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View | |
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View | |
SEE INSPECTOR COMMENTS | MAKE TIGHT ALL FITTINGS THROUGHOUT THE PROJECT.14E-3-300.12 | 2246 S WHIPPLE ST | PERMIT | PASSED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALLS;MORTAR MISSING AND FRACTURE WALLS. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING FOR 1990 THRU 2014. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR CORNICE | STONE CORNICE; OPEN JOINTS. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | WINDOW SILLS; OPEN JOINTS. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | BUILDING AREA; EXCESSIVE JUNK AND DEBRIS. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EXTERIOR STAIR TO PARKING AREA; TREADS AND STRINGER BROKEN,HAND RAILS MISSING. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST PORCH; NO FOOTINGS,TREADS WOOD SPLIT,GUARD RAILS BROKEN AND UNDER SIZE,UPRIGHTS SCAB TOGETHER AND OUT OF PLUMB,STRINGERS WOOD SPLIT,TREADS IMPROPER TREAD WIDTH,PORCH SYSTEM WEAK AND UNSTABLE [SUBMIT PLANS AND PERMITS TO REPLACE]. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
RAT STOP AROUND EXTERIOR | BUILDING AREA; RAT HOLES. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | NORTH AND SOUTH ELEVATION FOUNDATION WALLS; BROKEN CONCRETE. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQUIRED | NO PLANS AND PERMITS ON FILE FOR ATTIC DORMERS. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY CAPPING; MISSING. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | APARTMENT DOORS; NO PEEPHOLES. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOW SCREENS; MISSING OR TORN. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | SOUTH EXTERIOR DOOR AND DOOR PANE; BROKEN. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | SOUTH EXTERIOR DOOR FRAME; BROKEN. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | SOUTH INTERIOR STAIRS GRADE TO ATTIC LIGHT FIXTURE; HANGING. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | SOUTH INTERIOR STAIR WALLS; PLASTER BROKEN AND DETERIORATING. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
REMV RARELY USED FIXTURE | ATTIC UNUSED PLUMBING FACILITIES. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING , NO RESPONSE . UNABLE TO VERIFY SMOKE OR CARBON MONOXIDE ALARMS. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION - OPEN SILL JOINTS | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION - FRACTURED ENTRANCE STONE DOOR HEADER AND FRACTURES AT MASONRY WALL. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT STAIRS - SPALLED CONCRETE. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 2246 S WHIPPLE ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 2246 S WHIPPLE ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 2246 S WHIPPLE ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 2246 S WHIPPLE ST | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 2246 S WHIPPLE ST | COMPLAINT | CLOSED | View | |
SUBMIT FOR APPROVAL PLANS | 2246 S WHIPPLE ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 2246 S WHIPPLE ST | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 2246 S WHIPPLE ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 2246 S WHIPPLE ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 2246 S WHIPPLE ST | COMPLAINT | CLOSED | View | |
ATTIC AREA; DISCONTINUE SLEEPING ROOMS. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View | |
REPAIR/WRECK DANGER RESID PREM | 2246 S WHIPPLE ST | COMPLAINT | CLOSED | View | |
OBTAIN OR POST PERMIT | 2246 S WHIPPLE ST | COMPLAINT | CLOSED | View | |
PROVIDE | PROVIDE KITCHEN SINK UNIT 3 REAR. (13-196-390) | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO 1F, 2F UNITS. | 2246 S WHIPPLE ST | COMPLAINT | PASSED | View |
POST OWNER INFO ON ABDN BLDG | 2246 S WHIPPLE ST | COMPLAINT | CLOSED | View | |
ARRANGE FOR REINSPECTION REGAR | NO ENTRY TO APARTMENTS. | 2246 S WHIPPLE ST | COMPLAINT | FAILED | View |