The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | MISSING HANDRAIL. | 1536 E 80TH ST | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY. | 1536 E 80TH ST | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | NOT POSTED. | 1536 E 80TH ST | COMPLAINT | CLOSED | View |
NO KEY TO USE EXIT DOOR | DOUBLE KEY LOCKS ON GATES. | 1536 E 80TH ST | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | IMPROPER FOOTING'S,RAILS TOO LOW,OBTAIN PERMIT FOR REPAIRS. | 1536 E 80TH ST | COMPLAINT | CLOSED | View |
PARAPET | SOUTH PARAPET - STEP CRACK. | 1536 E 80TH ST | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | BASEMENT FLOOR DRAIN - BACKING UP. (SEWAGE WATER). | 1536 E 80TH ST | COMPLAINT | FAILED | View |
REPAIR CORNICE | SOUTH CORNICE - WASHED OUT MORTAR. | 1536 E 80TH ST | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | ALL COMMON INCLUDING BASEMENT AND EXTERIOR - NO ELECTRIC POWER. | 1536 E 80TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION,EXTERIOR STAIRS GRADE TO BASEMENT,MISSING HAND RAIL. | 1536 E 80TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | SOUTH ELEVATION,NO OWNERS I D SIGN POSTED. | 1536 E 80TH ST | COMPLAINT | PASSED | View |
NO KEY TO USE EXIT DOOR | FRONT AND REAR GATES ,DOUBLE KEYED LOCKS. | 1536 E 80TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION,1ST ,2ND FLOOR,EAST ELEVATION,1ST FLOOR WASHED OUT MORTAR SPALLING BRICKS. | 1536 E 80TH ST | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | EAST ELEVATION,SERVICE WALK,CRACKED CONCRETE. | 1536 E 80TH ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRS,MISSING SMOKE DETECTOR. | 1536 E 80TH ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | NORTH ELEVATION,REAR ENCLOSED AND OPEN PORCH SYSTEM,6 BY 6 COLUMNS SET ON CRACKED CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN,2 BY 8 JOISTS SPAN 12 FOOT 6 INCHES,JOISTS HANGERS ARE DETERIORATING ,RIM JOISTS ARE FACE NAILED ONLY,BEAMS ARE TOE NAILED TO COLUMNS ONLY,PULLING APART AT FIRE CUTS,COLUMNS ARE OVER NOTCHED,ROTTED AT BASE,RAILS ARE 30 INCHES HIGH,LOOSE AND PULLING,STAIR STRINGERS ARE FACE NAILED AT TOP AND BOTTOM CONNECTION,STRINGERS ARE SPLITTING,VARYING RISER HEIGHT OF 5,7, 8, 9 INCHES,DECKING BOARDS AT LANDING ARE ROTTED AND SPLITTING WITH HOLE THERE.PLANS AND PERMIT REQUIRED.(PORCH WAS CAUTION TAPED OFF AND POSTED DANGEROUS AND HAZERDOUS). | 1536 E 80TH ST | COMPLAINT | PASSED | View |
NO KEY TO USE EXIT DOOR | FRONT AND REAR GATES ,DOUBLE KEYED LOCKS. | 1536 E 80TH ST | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | BUILDING NO ENTRY TO BASEMENT,1ST, 2ND FLOOR UNITS TO CHECK OCCUPANCY,DETECTORS. | 1536 E 80TH ST | COMPLAINT | PASSED | View |
BASEMENT, DISCONTINUE | BASEMENT AT WEST-UTILIZED AS DWELLING UNIT | 1536 E 80TH ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE THE KITCHEN SINK AND COOKING DEVICE INSTALLED IN THE BASEMENT APARTMENT WITHOUT A PERMIT | 1536 E 80TH ST | COMPLAINT | PASSED | View |
PERMIT REQUIRED - CONTRACTOR | OBTAIN PERMIT FOR THE REMOVAL OF THE KITCHEN SINK AND GAS JET FOR THE COOKING DEVICE IN THE BASEMENT APARTMENT | 1536 E 80TH ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION,EXTERIOR STAIRS GRADE TO BASEMENT,MISSING HAND RAIL. | 1536 E 80TH ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRS,MISSING SMOKE DETECTOR. | 1536 E 80TH ST | COMPLAINT | PASSED | View |
BASEMENT, DISCONTINUE | BASEMENT AT WEST-UTILIZED AS DWELLING UNIT | 1536 E 80TH ST | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRIC INSTALLED IN THE BASEMENT WITHOUT PERMIT. | 1536 E 80TH ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | BASEMENT HAS BEEN CONVERTED INTO A DWELLING UNIT WITH KITCHEN AND BATHROOM. SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 1536 E 80TH ST | COMPLAINT | FAILED | View |
LIGHT AND VENT | BASEMENT DWELLING UNIT - MOST WINDOWS THAT CONSIST OF GLASS BLOCK TYPE WINDOWS WITH SMALL VENTS. | 1536 E 80TH ST | COMPLAINT | FAILED | View |
INSECTS | BASEMENT DWELLING UNIT - INFESTED WITH BUGS, INCLUDING SPIDERS, ANTS AND WARTER BUGS. | 1536 E 80TH ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT DWELLING UNIT / CARBON MONOXIDE DETECTOR - MISSING. | 1536 E 80TH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING NO ENTRY TO BASEMENT,1ST, 2ND FLOOR UNITS TO CHECK OCCUPANCY,DETECTORS. | 1536 E 80TH ST | COMPLAINT | FAILED | View |