Chicago Building Violations Data: 74 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM 5219 PORCH NO LEDGER BOLTS 4X4 UPRIGHT SCAB WORK STRINGER IMPROPER PITCH LOOKOUT PULLING AWAY 6X6 UPRIGHT PULLING APART RAIL SUPPORT PULLING AWAY FROM WALL 2ND FLOOR SECTION OF RAIL MISSING IMPROPER FOOTING 4X4 UPRIGHT OVERCUT INSUFFICIENT LAP JOINT CUT AND OUT OF PLUMB RIM JOIST PULLING AWAY 5221 PORCH 4X4 UPRIGHT OVERCUT INSUFFICIENT LAP JOINT CUT AND OUT OF PLUMB RIM JOIST PULLING AWAY 5221 PORCH 4X4 UPRIGHT SCAB NO LEDGER BOLTS SCAB WORK ON STRINGER STAIR SYSTEM IMPROPER SIZE LOOKOUT PULLING AWAY SCAB WORK ON 6X6 UPRIGHT LAP JOINT INSUFFICIENT CUT 5223 PORCH IMPROPER FOOTING AND MISSING UPRIGHT SPLIT AND OUT OF PLUMB LOOKOUT PULLING AWAY DECK JOIST ROTTED NO LEDGER BOLTS TREADS LOOSE PICKETS MISSING 5225 PORCH NO FOOTING PICKET MISSING IMPROPER STRINGER PITCH UPRIGHT OUT OF PLUMB 5219 S CALUMET AVE PERIODIC PASSED View
STOP/REMOVE NUISANCE 5221 INTERIOR STAIR WALL GRAFFITI 5219 S CALUMET AVE PERIODIC PASSED View
OBSTRUCTIONS IN EXIT WAY SERVICE AREA STORAGE ITEMS APARTMENT DOORS REAR DOORS BURGLAR BARS 5219 S CALUMET AVE PERIODIC PASSED View
REPAIR AREAWAY WALL AREAWAY WALL MORTAR MISSING 5219 S CALUMET AVE PERIODIC PASSED View
POST OWNER/MANAGERS NAME/# POST OWNERSHIP INSUFFICIENT INFORMATION 5219 S CALUMET AVE PERIODIC PASSED View
COVER OUTLETS AND JBS 5221 INTERIOR STAIRWALL OUTLET NO COVER PLATE 5219 S CALUMET AVE PERIODIC PASSED View
CARB MONOX DETECT IN RESID 5221 2-B 5219 2-A NO CARBON MONOXIDE DETECTOR 5219 S CALUMET AVE PERIODIC PASSED View
DEFECTIVE OUTLETS 5219 3-A LIVING LIGHT SWITCH DON'T WORK AND WALL OUTLETS 5219 S CALUMET AVE PERIODIC PASSED View
REPAIR FLOOR 5219 2-A LIVINGROOM WOOD FLOORING WOOD SPLIT 5219 S CALUMET AVE PERIODIC PASSED View
NO KEY TO USE EXIT DOOR 5219 2-B BALCONY DOOR KEYLOCK 5219 S CALUMET AVE PERIODIC PASSED View
STAIR: SELF-CLOSE 1-3/4" DOOR FOYER STAIRWELL DOORS MISSING 5219 S CALUMET AVE PERIODIC PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND PERMITS FOR REPAIRS 5219 S CALUMET AVE PERIODIC PASSED View
REPLACE DEFECTIVE TOILET SEAT 5219 2-B TOILET SEAT BROKEN 5219 S CALUMET AVE PERIODIC PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT ALL PERMITS FOR PORCHES AND ALL REHAB DRYWALL, PLUMBING, ELECTRICAL AND FORCED AIR UNITS. 5219 S CALUMET AVE COMPLAINT PASSED View
FILE BLDG REGISTRATION REGISTER BUILDING FOR 2006 AND 2007 5219 S CALUMET AVE COMPLAINT PASSED View
DEFECTIVE FIXTURES 5221 BASEMENT TEMP LIGHTS 5219 S CALUMET AVE COMPLAINT PASSED View
SECURE RACEWAY SUPPORT PIPE BASEMENT 1" EMT. 5219 S CALUMET AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM SCHEDULE APPOINTMENT TO HAVE REAR PORCHES INSPECTED PROVIDE PLANS AND PERMIT FOR INSPECTION 5219 S CALUMET AVE PERIODIC PASSED View
SUBMIT 2 COPY STRUCTURAL RPT DUE TO THE MANY DEFECTS AND DEFICIENT CONDITIONS COUPLED WITH IMPROPER WORKMANSHIP AN ENGINEERS REPORT IS REQUIRED 5219 S CALUMET AVE PERIODIC PASSED View
PLANS & PERMITS REQ - CONTRCTR THE ERECTION OF BRICK WALLS ON FRONT BALCONIES TO FORM FURNACE ROOMS PLANS AND PERMIT FOR CHANGING FROM COMMON PLANT TO INDIVIDUAL UNIT HEAT PLANT FOR REAR PORCHES REMODELING OF APARTMENTS 5219 S CALUMET AVE PERIODIC PASSED View
POST OWNER/MANAGERS NAME/# POST OWNERSHIP INFORMATION 5219 S CALUMET AVE PERIODIC PASSED View
STOP/REMOVE NUISANCE REMOVE GRAFFITI FROM STAIRWELL AT 5225 5219 S CALUMET AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR PORCH UNDER SIZED BRACKETS, COLUMNS BOWING, IMPROPER LAP CONNECTIONS, OBTAIN PERMIT FOR REPAIRS. 5219 S CALUMET AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM MISSING HAND RAILING FROM GRADE TO 1ST, 5223 AT 3RD MISSING PICKETS. 5219 S CALUMET AVE PERIODIC FAILED View
ROACHES ROACHES. 5219 S CALUMET AVE PERIODIC FAILED View
DEBRIS, EXCESSIVE BAR B QUE GRILLS ON LANDING'S. 5219 S CALUMET AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY MOST UNITS. 5219 S CALUMET AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCH UNDER SIZED BRACKETS, COLUMNS BOWING, IMPROPER LAP CONNECTIONS, OBTAIN PERMIT FOR REPAIRS. 5219 S CALUMET AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM MISSING HAND RAILING FROM GRADE TO 1ST, 5223 AT 3RD MISSING PICKETS. 5219 S CALUMET AVE PERIODIC FAILED View
ROACHES ROACHES. 5219 S CALUMET AVE PERIODIC FAILED View
DEBRIS, EXCESSIVE BAR B QUE GRILLS ON LANDING'S. 5219 S CALUMET AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY MOST UNITS. 5219 S CALUMET AVE PERIODIC FAILED View
SUBMIT REVISED PLANS FOR PERMT 5219 S CALUMET AVE COMPLAINT FAILED View
TEST PLUMBING SYSTEM 5219 S CALUMET AVE COMPLAINT FAILED View
ARRANGE FOR INPSECT OF PREMISE 5219 S CALUMET AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM NORTH ELEVATION / 3 STORY WOOD PORCHES / STEEL HARDWARE - RUSTING, ESPECIALLY JOST HANGERS. 5219 S CALUMET AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH AND EAST ELEVATIONS / EXTERIOR WALLS UNDER REAR ENTRY DOOR STONE SILLS - HOLES AND GAPS ( ENTRY POINTS FOR RODENTS ). 5219 S CALUMET AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF APTS. - NO ENTRY, UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO VERIFY COMPLAINT OF MICE AT 5219 APT 1A. 5219 S CALUMET AVE COMPLAINT FAILED View
STOP STORING GARBAGE NORTH ELEVATION / TENANTS ARE THROWING BAGS OF GARBAGE FROM REAR PORCHES INTO NEXT DOOR LOT ( RAT HARBORAGE ). 5219 S CALUMET AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE 5223 / FRONT ENTRY DOOR DOES NOT LATCH. DOOR IS OPEN AND NOT SECURE. 5219 S CALUMET AVE COMPLAINT FAILED View
REPAIR CATCH BASIN CATCH BASIN - HOLE IN COVER; CRACKED 5219 S CALUMET AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCHES - FOUNDATION STATUS UNKNOWN; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; #5219 - 2X8 JOISTS SPAN OVER 11'-0"; SPINDLE MISSING AT 1ST FLOOR;#5221 - LOOSE TREADS FROM GRADE TO 1ST FLOOR; SPINDLE MISSING AT 1ST FLOOR#5223 - 2X8 JOISTS SPAN OVER 11'-0".PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCHES. 5219 S CALUMET AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE BBQ GRILLS ON WOODEN PORCH DECKS THRU-OUT. 5219 S CALUMET AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELL, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY. 5219 S CALUMET AVE PERIODIC FAILED View
FILE BLDG REGISTRATION NOT REGISTERED 2011 5219 S CALUMET AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCHES - FOUNDATION STATUS UNKNOWN; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; #5219 - 2X8 JOISTS SPAN OVER 11'-0"; SPINDLE MISSING AT 1ST FLOOR;#5221 - LOOSE TREADS FROM GRADE TO 1ST FLOOR; SPINDLE MISSING AT 1ST FLOOR#5223 - 2X8 JOISTS SPAN OVER 11'-0".PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCHES. 5219 S CALUMET AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELL, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY. 5219 S CALUMET AVE PERIODIC FAILED View
CHIMNEY WASHED OUT MORTAR. 5219 S CALUMET AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCHES - FOUNDATION STATUS UNKNOWN; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; #5219 - 2X8 JOISTS SPAN OVER 11'-0"; SPINDLE MISSING AT 1ST FLOOR;#5221 - LOOSE TREADS FROM GRADE TO 1ST FLOOR; SPINDLE MISSING AT 1ST FLOOR#5223 - 2X8 JOISTS SPAN OVER 11'-0".PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCHES. 5219 S CALUMET AVE PERIODIC FAILED View
CHIMNEY WASHED OUT MORTAR. 5219 S CALUMET AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCHES - FOUNDATION STATUS UNKNOWN; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; #5219 - 2X8 JOISTS SPAN OVER 11'-0"; SPINDLE MISSING AT 1ST FLOOR;#5221 - LOOSE TREADS FROM GRADE TO 1ST FLOOR; SPINDLE MISSING AT 1ST FLOOR#5223 - 2X8 JOISTS SPAN OVER 11'-0".PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCHES. 5219 S CALUMET AVE PERIODIC FAILED View
REPAIR BALCONY ALL EXTERIOR BALCONYS /2X4 WOOD TOP AND BOTTOM RAILS INSTALLED ABOVE BRICK, WITH LATTICE INSTALLED AT OUTSIDE OF RAILS; PICKETS - MISSING; 5219 S CALUMET AVE PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR YARD GATES LOCKED, DIAL UP KEY PAD - OUT OF SERVICE - NO ENTRY;UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY;UNABLE TO INSPECT INTERIOR STAIRWAY; UNABLE TO INSPECT REAR PORCH; 5219 S CALUMET AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCHES - FOUNDATION STATUS UNKNOWN; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; #5219 - 2X8 JOISTS SPAN OVER 11'-0"; SPINDLE MISSING AT 1ST FLOOR;#5221 - LOOSE TREADS FROM GRADE TO 1ST FLOOR; SPINDLE MISSING AT 1ST FLOOR#5223 - 2X8 JOISTS SPAN OVER 11'-0".PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCHES. 5219 S CALUMET AVE PERIODIC FAILED View
NO POSTED ADDRESS POST ADDRESS RANGE OF BUILDING SO IT IS VISIBLE FROM THE STREET. 5219 S CALUMET AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - POST CURRENT, CORRECT AND COMPLETE INFORMATION. 5219 S CALUMET AVE PERIODIC FAILED View
FIRE EXTNGSHR RECHARGE & TAG INTERIOR OF BUILDING - FIRE EXTINGUISHERS WITH EXPIRED TAGS (2014). 5219 S CALUMET AVE PERIODIC FAILED View
NO POSTED ADDRESS POST ADDRESS RANGE OF BUILDING SO IT IS VISIBLE FROM THE STREET. 5219 S CALUMET AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - POST CURRENT, CORRECT AND COMPLETE INFORMATION. 5219 S CALUMET AVE PERIODIC FAILED View
FIRE EXTNGSHR RECHARGE & TAG INTERIOR OF BUILDING - FIRE EXTINGUISHERS WITH EXPIRED TAGS (2014). 5219 S CALUMET AVE PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR INTERIOR OF BUILDING NO RESPONSE.UNVERIFIED COMPLAINT OF MOLD AT 5223 UNIT 1A.UNVERIFIED COMPLIANCE ON EXISTING VIOLATIONS.UNVERIFIED OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2018 ANNUAL INSPECTION. 5219 S CALUMET AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - POST CURRENT, CORRECT AND COMPLETE INFORMATION. 5219 S CALUMET AVE PERIODIC FAILED View
FIRE EXTNGSHR RECHARGE & TAG INTERIOR OF BUILDING - FIRE EXTINGUISHERS WITH EXPIRED TAGS (2014). 5219 S CALUMET AVE PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR MOST DWELLING UNITS - NO RESPONSE, UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS. 5219 S CALUMET AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR HARDWARE FRONT EXTERIOR DOOR AT 5223 S./ - LOOSE TOP HINGE AND DEFECTIVE SELF-CLOSER. 5219 S CALUMET AVE PERIODIC FAILED View
ILLUMINATE EXIT AREAS FRONT INTERIOR STAIRWAY AT 5219 S./ - LIGHT FIXTURES WERE OFF AT TIME OF INSPECTION ( VERY DARK). 5219 S CALUMET AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIRS AT 5223 S./ , 2ND TO 3RD FLOOR, HANDRAILS ARE MISSING BALUSTERS. 5219 S CALUMET AVE PERIODIC FAILED View
DEFECTIVE FIXTURES FRONT INTERIOR STAIRWAY AT 5223 S./, EMERGENCY LIGHT - FAILED TEST. 5219 S CALUMET AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS FRONT INTERIOR STAIRWAY AT 5223 S./ - SMOKE DETECTOR IS CHIRPING. 5219 S CALUMET AVE PERIODIC FAILED View
DEBRIS, EXCESSIVE NORTH SERVICE AREA AND FRONT YARD - REFUSE ACCUMULATION. 5219 S CALUMET AVE PERIODIC FAILED View
INSTALL COVERS 5219 2-A BATHROOM HALLWAY LIGHT FIXTURE MISSING 5219 S CALUMET AVE PERIODIC PASSED View
REPAIR INTERIOR WALLS/CEILING WATER DAMAGE CEILING AT BATHROOM 1B 5225 5219 S CALUMET AVE COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# NO POSTING OF OWNERSHIP 5219 S CALUMET AVE COMPLAINT PASSED View
FILE BLDG REGISTRATION NOT REGISTERED 2011 5219 S CALUMET AVE PERIODIC FAILED View