Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PARAPET | WEST ELEVATION / PARAPET - WASHED OUT MORTAR. | 8241 S CLYDE AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | WEST ELEVATION / CORNICE - OPEN MORTAR JOINTS . | 8241 S CLYDE AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | NORTH ELEVATION / CHIMNEY CAP - MISSING. | 8241 S CLYDE AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | WEST AND NORTH ELEVATION / LINTELS - RUSTED AND BENT. PLANS AND PERMIT REQUIRED TO REPLACE LINTELS. | 8241 S CLYDE AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | WEST ELEVATION / WINDOW SILLS - OPEN MORTAR JOINTS. | 8241 S CLYDE AVE | COMPLAINT | FAILED | View |
CHIMNEY | NORTH ELEVATION / CHIMNEY - WASHED OUT MORTAR. | 8241 S CLYDE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION / EXTERIOR WALL - WASHED OUT MORTAR. | 8241 S CLYDE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST ELEVATION / EXTERIOR STAIR - BASEMENT TO GRADE HAND RAIL MISSING . | 8241 S CLYDE AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | EAST ELEVATION / 2 STORY EXTERIOR PORCH - 6X6 COLUMNS ERECTED ON SERVICE WALK . 4X4 COLUMNS SCAB WITH 2X4 JOIST NAILED TO HEADERS. 6X6 COLUMN PULLING AWAY FROM COLUMN 2 INCH GAP .STRINGERS NAILED TO WALL.1ST FL RISER 4 INCHES HIGH. DECK BOARDS AND TREADS ROTTED.GUARD RAILS AND STRINGER NAILED ONLY TO COLUMNS,HEADERS AND WALL. GUARD RAILS LOOSE AND ROTTED. PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH . | 8241 S CLYDE AVE | COMPLAINT | FAILED | View |
ABANDONED REFRIGERATOR | REAR YARD AND 2ND FL PORCH /(2) ABANDONED REFRIGERATORS . | 8241 S CLYDE AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | EAST ELEVATION / GARAGE - CHIMNEY BRICKS MISSING CHIMNEY CAP MISSING EXTERIOR WALL - WASHED OUT MORTAR AND SPALLING BRICKS. EAST EXTERIOR WALL MISSING BRICKS. GARAGE SAGGING 2FT AT CENTER OF FLAT ROOF. GARAGE ROOF ROTTEDPARAPET WALL WASHED OUT MORTAR 2X8 USED TO SHORE UP THE ROOF OVER HEAD GARAGE DOOR ROTTED. OVER HEAD GARAGE DOOR 16FT HEADER MISSING PERMIT REQUIRED TO REPAIR REAR PORCH . | 8241 S CLYDE AVE | COMPLAINT | FAILED | View |