SUBMIT FOR APPROVAL PLANS | VIOLATION CLOSED PER PCR 1180 | 5842 S SANGAMON ST | COMPLAINT | CLOSED | View |
MAINTAN BLDG IN SAFE CONDITION | VIOLATION CLOSED PER PCR 1180 | 5842 S SANGAMON ST | COMPLAINT | CLOSED | View |
REPAIR/WRECK DANGER RESID PREM | VIOLATION CLOSED PER PCR 1180 | 5842 S SANGAMON ST | COMPLAINT | CLOSED | View |
WATCHMAN | VIOLATION CLOSED PER PCR 1180 | 5842 S SANGAMON ST | COMPLAINT | CLOSED | View |
POST OWNER NAME OF VACNT BLDG | VIOLATION CLOSED PER PCR 1180 | 5842 S SANGAMON ST | COMPLAINT | CLOSED | View |
FILE BLDG REGISTRATION | VIOLATION CLOSED PER PCR 1180 | 5842 S SANGAMON ST | COMPLAINT | CLOSED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST FLOOR APARTMENT - SMOKE DETECTOR - OUT OF SERVICE, WITH MISSING BATTERY. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | VIOLATION CLOSED PER PCR 1180 | 5842 S SANGAMON ST | COMPLAINT | CLOSED | View |
OPEN | 5842 S SANGAMON ST | PERMIT | FAILED | View | |
UNAPPROVED HEATING DEVICE | USING PORTABLE HEATING EQUIPMENT. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | HEATING SYSTEM IS OFF AT TIME OF INSPECTION, NO HEAT PROVIDED. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | HOT WATER SUPPLIED AT ONLY 60 DEGREES. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING UNIT 2-NO ENTRY, UNABLE TO VERIFY COMPLAINT SR131395340. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S ID SIGN POSTED. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT PORCH LOOSE HANDRAILS. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
RAT PROOF OPENINGS | 1ST FLOOR AND BASEMENT - MULTIPLE RAT HOLES ON FLOORS. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | 1ST FLOOR APARTMENT - BEDROOM - WALL OUTLET LOOSE AND HANGING. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST FLOOR BATHROOM - FLOOR BY TOILET SEAT SINKING. BASEMENT FLOOR - BROKEN CONCRETE SLAB. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
USE SANITARY REFUSE CONTAINERS | REAR ENCLOSED PORCH AND BASEMENT - ACCUMULATION OF REFUSE AND GARBAGE. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
RATS | 1ST FLOOR APARTMENT - RATS INFESTATION. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
REPAIR BALCONY | FRONT BALCONY. THE 2 STRUCTURAL COLUMNS SUPPORTING THE LOAD OF THIS 2CD LEVEL BALCONY HAVE BRICKWORK THAT IS LOOSR / DISPLACED WITH ERODED BRICK MORTAR. THE COLUMNS THEMSELVES ARE VISABLY OUT OF PLUMB. THIS CONDITION, COUPLED WITH THE SEVERELY SAGGING STRUCTURAL BEAM BETWEEN THESE 2 COLUMN, HAS GREATLY REDUCED THE STRUCTURAL INTEGRITY OF THIS BALCONY AND THE OVERALL CONDITION IS DANGEROUS AND HAZARDOUS. PLANS AND PERMIT ARE REQUIRED FOR REPAIRS. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH ... 1 LEVEL. THE STAIR STRINGERS ARE OVER CUT. THERE ARE NUMEROUS LOOSE STAIR TREADS. THIS PORCH HAS FLOOR JOISTS THAT ARE OVER SPANNED WITH NO JOIST HANGERS. THE PORCH BANISTERS ARE TOO LOW AT 34" AND HAVE NO INTERMEDIATE BANISTER POST. THESE BANISTERS DEFLECT UNDER LOAD. THE BRICKWORK FOR THE SUPPORT COLUMNS IS LOOSE / DISPLACED. THIS PORCH IS IN UNSAFE CONDITION. PERMIT REQUIRED FOR REPAIRS. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO MANAGEMENT SIGN POSTED. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | THE CONCRETE SERVICE WALK IS SEVERELY CRACKED / BUCKLED. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | BACK YARD IS FULL OF JUNK / DEBRIS. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | THE REAR YARD HAS A LARGE AMOUNT OF VEGITATION DEBRIS. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
CHIMNEY | THE BRICK CHIMNEY HAS LOOSE / SPALLED BRICKWORK. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
PARAPET & COPING | THE FRONT PARAPETT WALL HAS SEVERELY ERODED BRICK MORTAR. THERE ARE SMALL PLANTS GROWING OUT OF THE MORTAR VOIDS AT THIS PARAPETT. THE BRICKWORK IS BECOMING LOOSE / DISPLACED. PERMIT REQUIRED FOR REPAIRS. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BLDG. - OWNER'S I.D. SIGN - MISSING | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR YARD - ABANDONED AUTOMOBILE VEHICLES. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
PRV CAST IRON COVER FOR BASIN | REAR YARD - CATCH BASIN OPEN AND MISSING COVER - DH CONDITIONS. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | REAR ENCLOSED PORCH - DOWNSPOUT SECTION BROKEN AND MISSING SECTIONS. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | BASEMENT, REAR ENCLOSED PORCH AND REAR YARD - ACCUMULATION OF JUNK AND DEBRIS - SEE USED AND DISCARDED TV, STOVES, BABY BOUNCERS, MATTRASS FOAMS AND BOXES - FIRE HAZARDS. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR ENCLOSED PORCH AND BASEMENT TO 1 STAIRCASE - JUNK AND DEBRIS OBSTRUCTING EGRESS. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
PARAPET | NORTH AND SOUTH ELEVATIONS - PARAPET WALLS - BRICKS SPALLING AND WASHED OUT MORTAR. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | BASEMENT / FURNACE ROOM - CEILING OPEN , WITH EXPOSED FLOOR JOISTS. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | 1ST FLOOR APARTMENT DUPLEXED TO BASEMENT REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING ELECTRIC AND HVAC) INSTALLED IN BASEMENT WITHOUT PERMIT. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALL ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO ITS ORIGINAL CONDITIONS. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
HEATING PLANT SEPARATION | BASEMENT DWELLING SPACE SEPARATED FROM HEATING PLANT BY A PARTITION OF 1/2 INCH DRYWALL ON ONE SIDE OF THE STUDS ONLY. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 1-STORY / FRONT PORCH: UNDERSIZED 2X8 DECK JOISTS SPAN 22 FEET, SAGGING AND ONLY TOE-NAILED TO HEADER BEAMS. RAILING AND GUARDRAIL SECTIONS ONLY TOE-NAILED TO MASONRY COLUMNS AND WALL, SPAN 10 FEET, LOOSE AND PULLING OUT. LOOSE TREADS. PLANS AND PERMIT REQUIRED TO REPAIR FRONT PORCH. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT ENTRANCE DOOR - SIDEGLASS BROKEN AND BOARDED UP. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
REPAIR DOOR HARDWARE | FRONT STAIRWAY DOOR - KNOB MISSING. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | REAR ENCLOSED PORCH - SMOKE DETECTOR - MISSING. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR APARTMENT - CARBON MONOXIDE DETECTOR - MISSING. BASEMENT / FURNACE - CARBON MONOXIDE DETECTOR - OUT OF SERVICE, WITH MISSING BATTERY. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
INSECTS | ENTIRE BUILDING, INCLUDING 1ST FLOOR APARTMENT - BEDBUGS INFESTATION. PROPERTY MUST BE EFFECTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT, BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
MICE/RODENTS | 1ST FLOOR APARTMENT - MICE INFESTATION | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | BASEMENT - CEILING AND BASEMENT STAIRWELL WALL - BROKEN AND CRUMBLING PLASTER, WITH EXPOSED LATH. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | BASEMENT - LARGE OPENING ON CEILING INTO 1ST FLOOR, THROUGH UNINSULATED HEATING VENTS. INTERIOR PARTITION WALLS BROKEN AND FALLING APART. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR BASEMENT TO 1 / STAIRWAY - RAILING SECTIONS MISSING BALUSTERS. RISER BOARDS MISSING AT VARIOUS LOCATIONS. SECTIONS OF UNDERSIDE CEILING PLASTER BROKEN AND MISSING. TREADS AND RISER BOARDS LOOSE SHIFTING. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
REPAIR DOOR FRAME, MULLION | 1ST FLOOR APARTMENT - ENTRY DOOR FRAME - BROKEN AND SPLIT. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | INTERIOR OF BUILDING, INCLUDING BASEMENT, 1ST FLOOR APARTMENT AND REAR ENCLOSED PORCH - FILTHY AND UNSANITARY. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR 2-STORY ENCLOSED PORCH IS IN DANGEROUS AND HAZARDOUS CONDITIONS.ENTIRE STRUCTURE IS WEAK AND SEPARATING FROM MASONRY WALL.1ST AND 2ND FLOOR DECK SLOPED EXCESSIVELY WITH 6X6 BEAMS PULLING AWAY FROM OPEN POCKETS.COLUMNS COVERED WITH DRYWALL AND PANELING UNABLE TO VERIFY THE CONDITIONS.PLANS AND PERMIT REQUIRED FOR REAR PORCH REPLACEMENT. | 5842 S SANGAMON ST | COMPLAINT | FAILED | View |