The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
HEAT UNIT ADEQUATELY | 1ST FLOOR (67 DEGREES)GAS METERS IN BASEMENT FOR 1ST AND 2ND FLOOR REMOVED. | 5406 S BISHOP ST | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 1ST FLOOR DINING ROOM SMOKE DETECTOR BEEPING. | 5406 S BISHOP ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 5406 S BISHOP ST | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | FRONT YARD GATE - DOUBLE KEY LOCK. | 5406 S BISHOP ST | COMPLAINT | FAILED | View |
PARAPET | NORTH ELEVATION/ PARAPET WALL - LEANING INWARD. | 5406 S BISHOP ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT ELEVATION/ EXTERIOR WALL/ MASONRY COLUMNS - WASHED OUT AT BOTTOM.REAR ELEVATION/ EXTERIOR WALL - SIDING MISSING NEAR TOP.(VIEWED FROM ALLEY). | 5406 S BISHOP ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT 1-STORY WOOD PORCH/ UNDERSIZED 2X6 DECK JOISTS SPAN APPROXIMATELY 12 TO 15 FEET.2X6 DECK JOISTS ARE TEMPORARILY SHORED UP WITH 2X4 BOARDS. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 5406 S BISHOP ST | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE/ OVERHEAD DOOR - BOARDED UP. | 5406 S BISHOP ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY - MISSING CAPPING. | 5406 S BISHOP ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S I.D. SIGN HAS INCOMPLETE INFORMATION POSTED: MISSING MAILING ADDRESS. | 5406 S BISHOP ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR APT. - MISSING SMOKE DETECTOR. | 5406 S BISHOP ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR APT. - MISSING CARBON MONOXIDE DETECTOR. | 5406 S BISHOP ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR 2-STORY ENCLOSED PORCH/ BEAMS - ONLY NAILED TO COLUMNS. COLUMNS - DOUBLE NOTCHED FOR HEADER JOISTS. UNDERSIZED 2X8 DECK JOISTS SPAN 9 TO 12 FEET. STRINGERS - UPPER ENDS INADEQUATELY SUPPORTED WITH NAILS ONLY. 1ST FLOOR DECK/ CEILING - BROKEN, MISSING AND HANGING DRYWALL WITH EXPOSED WOOD. PLANS AND PERMIT REQUIRED FOR REAR PORCH REPAIRS.FRONT 1-STORY PORCH/ RAILINGS - ONLY 31 INCHES HIGH. | 5406 S BISHOP ST | COMPLAINT | PASSED | View |
PARAPET | NORTH ELEVATION/ PARAPET WALL - LOOSE BRICKS WITH WASHED OUT MORTAR; LEANING INWARD OVER PUBLIC SERVICE WALK.DANGEROUS AND HAZARDOUS CONDITIONS.PERMIT REQUIRED FOR MASONRY REPAIRS. | 5406 S BISHOP ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | SOUTH AND NORTH ELEVATIONS/ EXTERIOR WALLS - SPALLING BRICKS WITH WASHED OUT MORTAR. | 5406 S BISHOP ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR APT. - MISSING SMOKE DETECTOR. | 5406 S BISHOP ST | COMPLAINT | PASSED | View |
CHIMNEY CAPPING | SOUTHEAST AND SOUTHWEST CHIMNEYS - MISSING CAPPINGS. | 5406 S BISHOP ST | COMPLAINT | PASSED | View |
PROVIDE COLD WATER TO FICTURES | 1ST FLOOR HOT WATER FROM KITCHEN SINK (61 DEGREES). | 5406 S BISHOP ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS AND REAR PORCH. | 5406 S BISHOP ST | COMPLAINT | FAILED | View |