Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 2:58 PM
PIN: 20074260330000
Property Address: 1856 W GARFIELD BLVD
City - Zip: CHICAGO - 60609
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72091
2023 Tax District: 72014
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 25 Violations
Violation Inspector Comments Address Category Status View
HEAT UNIT ADEQUATELY 2ND FLOOR 61.2 DEGREES 1856 W GARFIELD BLVD COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO MANAGEMENT SIGN POSTED. 1856 W GARFIELD BLVD COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS REAR FIRST WINDOW ... SHATTEREWD PANE. 1856 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS 2CD FLOOR UNIT ... DEFECTIVE SMOKE DETECTOR. 1856 W GARFIELD BLVD COMPLAINT FAILED View
INSTALL SMOKE DETECTORS INTERIOR STAIRS ... NO SMOKE DETECTOR. 1856 W GARFIELD BLVD COMPLAINT FAILED View
DEBRIS, EXCESSIVE BASEMENT ... JUNK AND DEBRIS. 1856 W GARFIELD BLVD COMPLAINT FAILED View
SAFE WORKING CONDITIONS 1ST FLOOR UNIT ... FURNACE IS INOPERABLE. 1856 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR FLOOR 1ST FLOOR UNIT ... NO FINISHED FLOORING. PLYWOOD FLOORS. 1856 W GARFIELD BLVD COMPLAINT FAILED View
DEFECTIVE OUTLETS 1ST FLOOR UNIT ... MULTIPLE DEFECTIVE OUTLETS. 1856 W GARFIELD BLVD COMPLAINT FAILED View
DEFECTIVE FIXTURES 1ST FLOOR UNIT ... DEFECTIVE LIGHT FIXTURE. 1856 W GARFIELD BLVD COMPLAINT FAILED View
REPLACE D&H PORCH REAR PORCH ... 2 STORIES. ALL RAILINGS TOO LOW (24" TO 28"). THESE RAILINGS DEFLECT UNDER LOAD. THERE ARE NO FLOOR JOIST HANGERS. ALL STRUCTURAL COLUMNS ARE OVERNOTCHED. THE COLUMN SECTIONS ARE JOINED BY INSUFFICIENT (12" / 2 BOLT) LAP JOINTS. THERE ARE MULTIPLE LOOSE STAIR TREADS. THERE ARE BROKEN AND MISSING PICKETTS. THE STAIR FLIGHT WIDTH IS TOO NARROW AT 24". THE BANISTER SECTIONS HAVE NO INTERMEDIATED POSTS. THE STRUCTURAL COLUMNS HAVE INSUFFICIENT FOOTINGS AND ARE SET ON EITHER MAKE SHIFT WOOD FOOTINGS OR DIRECTLY ONTO THE GROUND (SOIL). THIS PORCH IS BEYOND REPAIR AND IS DANGEROUS AND HAZARDOUS. TEAR DOWN AND REPLACE WITH NEW. PLANS AND PERMIT ARE REQUIRED, 1856 W GARFIELD BLVD COMPLAINT FAILED View
REPLACE D&H PORCH REAR PORCH ... 2 STORIES. ALL RAILINGS TOO LOW (24" TO 28"). THESE RAILINGS DEFLECT UNDER LOAD. THERE ARE NO FLOOR JOIST HANGERS. ALL STRUCTURAL COLUMNS ARE OVERNOTCHED. THE COLUMN SECTIONS ARE JOINED BY INSUFFICIENT (12" / 2 BOLT) LAP JOINTS. THERE ARE MULTIPLE LOOSE STAIR TREADS. THERE ARE BROKEN AND MISSING PICKETTS. THE STAIR FLIGHT WIDTH IS TOO NARROW AT 24". THE BANISTER SECTIONS HAVE NO INTERMEDIATED POSTS. THE STRUCTURAL COLUMNS HAVE INSUFFICIENT FOOTINGS AND ARE SET ON EITHER MAKE SHIFT WOOD FOOTINGS OR DIRECTLY ONTO THE GROUND (SOIL). THIS PORCH IS BEYOND REPAIR AND IS DANGEROUS AND HAZARDOUS. TEAR DOWN AND REPLACE WITH NEW. PLANS AND PERMIT ARE REQUIRED, 1856 W GARFIELD BLVD COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# NO MANAGEMENT SIGN POSTED. 1856 W GARFIELD BLVD COMPLAINT PASSED View
FILE BLDG REGISTRATION NO RECORD OF BUILDING REGISTRATION. 1856 W GARFIELD BLVD COMPLAINT PASSED View
REPLCE WINDOW PANES, PLEXGLAS REAR FIRST WINDOW ... SHATTEREWD PANE. 1856 W GARFIELD BLVD COMPLAINT PASSED View
REPAIR/REPLACE SMOKE DETECTORS 2CD FLOOR UNIT ... DEFECTIVE SMOKE DETECTOR. 1856 W GARFIELD BLVD COMPLAINT PASSED View
INSTALL SMOKE DETECTORS INTERIOR STAIRS ... NO SMOKE DETECTOR. 1856 W GARFIELD BLVD COMPLAINT PASSED View
DEBRIS, EXCESSIVE BASEMENT ... JUNK AND DEBRIS. 1856 W GARFIELD BLVD COMPLAINT PASSED View
STOP LEAKING WATER BASEMENT ... WATER STAINED WALLS ... FREQUENT FLOODING IN BASEMENT. 1856 W GARFIELD BLVD COMPLAINT PASSED View
SAFE WORKING CONDITIONS 1ST FLOOR UNIT ... FURNACE IS INOPERABLE. 1856 W GARFIELD BLVD COMPLAINT PASSED View
REPAIR FLOOR 1ST FLOOR UNIT ... NO FINISHED FLOORING. PLYWOOD FLOORS. 1856 W GARFIELD BLVD COMPLAINT PASSED View
DEFECTIVE OUTLETS 1ST FLOOR UNIT ... MULTIPLE DEFECTIVE OUTLETS. 1856 W GARFIELD BLVD COMPLAINT PASSED View
DEFECTIVE FIXTURES 1ST FLOOR UNIT ... DEFECTIVE LIGHT FIXTURE. 1856 W GARFIELD BLVD COMPLAINT PASSED View
FILE BLDG REGISTRATION NO RECORD OF BUILDING REGISTRATION. 1856 W GARFIELD BLVD COMPLAINT FAILED View
STOP LEAKING WATER BASEMENT ... WATER STAINED WALLS ... FREQUENT FLOODING IN BASEMENT. 1856 W GARFIELD BLVD COMPLAINT FAILED View