Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 4:07 AM
PIN: 20244030130000
Property Address: 6728 S PAXTON AVE
City - Zip: CHICAGO - 60649
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70083
2023 Tax District: 70131
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 19 Violations
Violation Inspector Comments Address Category Status View
PARAPET SOUTH, WEST ELEVATIONS - PARAPET WALL - WASHED OUT MORTAR 6728 S PAXTON AVE COMPLAINT FAILED View
CUT OR REMOVE HIGH WEEDS WEEDS THROUGHOUT FRONT YARD 6728 S PAXTON AVE COMPLAINT FAILED View
REPAIR FENCE FRONT METAL GATE - BROKEN AND REMOVED; LEANING AGAINST METAL FENCE 6728 S PAXTON AVE COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE - DOWNSPOUT MISSING 6728 S PAXTON AVE COMPLAINT FAILED View
REPAIR GUTTER GUTTER - RUSTING 6728 S PAXTON AVE COMPLAINT FAILED View
REPAIR SCREENS BASEMENT - WINDOW SCREEN - LOOSE 6728 S PAXTON AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, REAR PREMISES, AND REAR PORCH. UNVERIFIED DETECTORS AND CONDITIONS. 6728 S PAXTON AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BLDG. - OWNER'S I.D. SIGN - MISSING 6728 S PAXTON AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BLDG: NO RESPONSE - UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. UNABLE TO INSPECT REAR PORCH AND VERIFY COMPLAINTS OF MICE AND WATER LEAKAGE AT BASEMENT AND 2ND FLOOR. 6728 S PAXTON AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR FRAME FRONT ENTRANCE DOOR FRAME - ROTTING AT BASE, WITH PEELING PAINT. 6728 S PAXTON AVE PERIODIC FAILED View
PARAPET & COPING EAST ELEVATION - PARAPET WALL AND COPING - OPEN JOINTS AND WASHED OUT MORTAR. 6728 S PAXTON AVE PERIODIC FAILED View
REPAIR WINDOW SILLS EAST ELEVATION - WINDOW SILLS - OPEN JOINTS AND WASHED OUT MORTAR. 6728 S PAXTON AVE PERIODIC FAILED View
REPAIR CORNICE EAST ELEVATION - CORNICE - OPEN JOINTS AND WASHED OUT MORTAR. 6728 S PAXTON AVE PERIODIC FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE - GUTTERS BROKEN AND TWISTED, WITH DOWNSPOUT SECTION MISSING. 6728 S PAXTON AVE PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR 6 FT. HIGH WROUGHT IRON FENCE AND GATES INSTALLED WITHOUT A PERMIT. 6728 S PAXTON AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS FRONT TOP OF STAIRWELL, - SMOKE DETECTOR OUT OF SERVICE. 6728 S PAXTON AVE PERIODIC FAILED View
CUT OR REMOVE HIGH WEEDS AT WEST ELEVATION, - CUT AND REMOVE DRY WEEDS PILE UP AND BROKEN FENCE ON TOP OF DRY WEEDS, - POTENTIAL FIRE HAZARD. 6728 S PAXTON AVE PERIODIC FAILED View
REPLACE D&H PORCH REAR WOOD PORCH, COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES; FOUNDATION STATUS UNKNOWN, - - 6X6 COLUMNS NOT ATTACHED TO FOOTINGS, - 6X6 COLUMNS HAVE INADEQUATE HALF-LAP JOINTS WITH ONLY TWO (2) 1/2" BOLTS IN DIAMETER, THROUGHOUT ENTIRE PORCH,- 4X4 COLUMNS HAVE INADEQUATE HALF-LAP JOINTS WITH OVERLAPS OF ONLY 5-1/2" FASTENED WITH NAILS ONLY ALL FLOORS, - TOP FLOOR LEDGER BEAMS FASTENED TO EXTERIOR WALLS WITH NAILS ONLY. - AT 1ST FLOOR GUARD RAIL IS VERY LOOSE ALMOST FALLING OFF, NAILS HOLDING GUARD RAIL ARE GONE ONLY TWO NAILS HOLDING GUARDRAILGUARD RAIL IS LESS THEN 42" IN HEIGHT,- PLANS AND PERMIT ARE REQUIRED TO REPLACE PORCH.PLEASE NOTE THAT I STICKER PORCH REGARDING LOOSE GUARDRAIL. 6728 S PAXTON AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BLDG. - NOT REGISTERED FROM 1990 THRU 2014 6728 S PAXTON AVE PERIODIC FAILED View