Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 5:41 AM
PIN: 11304110090000
Property Address: 7407 N CLARK ST
City - Zip: CHICAGO - 60626
2023 Property Class: 318
2023 Township: 75 - Rogers Park
2023 Neighborhood: 75032
2023 Tax District: 75001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 15 Violations
Violation Inspector Comments Address Category Status View
ARRANGE FOR REINSPECTION REGAR INTERIOR OF BUILDING /MOST APTS - NO RESPONSE. UNVERIFIED DETECTORS AND CONDITIONS. APT 2S - UNVERIFIED COMPLAINT OF ROACHES. 7407 N CLARK ST PERIODIC FAILED View
PRV HIGH SIDE FOR ONE TURBO AIR / COPELAND 3 HP. COMPRESSOR SERVING THE 8 DOOR COOLER. LOCATED ON REAR WALL. 6"X20" RECEIVER. 7407 N CLARK ST PERIODIC FAILED View
RATS MULTIPLE RAT HOLES-REAR YARD 7407 N CLARK ST PERIODIC FAILED View
REPAIR FLOOR 7407 1ST FLOOR BUSINESS SHOP-FLOOR MISSING TILES 7407 N CLARK ST PERIODIC FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE-7407 1ST FLOOR BUSINESS SHOP 7407 N CLARK ST PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING BSMT BROKEN CEILINGS & WALLS, -7407 BSMNT FLOOR 7407 N CLARK ST PERIODIC FAILED View
MAINTAIN WINDOW ROTTED WINDOW FRAMES-NORTH ELEVATION 7407 N CLARK ST PERIODIC FAILED View
REPAIR EXTERIOR WALL REAR ELEVATION-CRACKS ON WALL, BRICKS LOOSE MORTAR JOINTS 7407 N CLARK ST PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCH SYSTEM-STRINGERS NOT BOLTED TO WALLS & COLUMNS, COLUMNS & BEAMS NOT BOLTED-TIE NAILS PULLING OFF. GUARDRAIL <42" HEIGHT& RAILINGS <32" HEIGHT. COLUMNS SUPPORTED BY CRACKED CONCRETE BLACKS-FOUNDATION UNKNOWN. DECK BOARDS SEVERELY DAMAGED & ROTTED. ALL MEMBERS OF THE PORCH-GUARDRAILS, HANDRAILS, PICKETS, COLUMNS, ETC., SEVERELY DAMAGED & ROTTED. COLUMNS ARE STACKED WITHOUT PROPER CONNECTIONS. 7407 N CLARK ST PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS & OBTAIN PERMIT TO REPLACE DILAPIDATED & DANGEROUS PORCH 7407 N CLARK ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY INTO THE APT. UNITS FOR INSPECTIONS. ALSO THE BOILER RM 7407 N CLARK ST PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR INTERIOR OF BUILDING- NO RESPONSE,UNVERIFIED DETECTORS AND CONDITIONS. UNVERIFIED DETECTORS IN FRION STSIRWAYS. UNVERIFIED COMPLAINT OF 7411N/ APT #2- BED BUGS. 7407 N CLARK ST PERIODIC FAILED View
REPAIR WINDOW SILLS SOUTH ELEVATION-SECOND AND THIRD FLOORS-STONE SILLS-WASHED OUT MORTAR. 7407 N CLARK ST PERIODIC FAILED View
SCREEN OUTER DOORS, WINDOWS FRONT AND REAR ELEVATIONS-FIRST THRU THIRD FLOORS-MISSING SCREENS. 7407 N CLARK ST PERIODIC FAILED View
REPAIR EXTERIOR WALL FRONT ELEVATIONS-7408 W/ AT FIRST FLOOR- FRACTURED MASONRY,WASHED OUT MORTAR. 7407 N CLARK ST PERIODIC FAILED View