Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 1:44 AM
PIN: 20183150010000
Property Address: 6201 S SEELEY AVE
City - Zip: CHICAGO - 60636
2023 Property Class: 315
2023 Township: 72 - Lake
2023 Neighborhood: 72120
2023 Tax District: 72163
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 72 Violations
Violation Inspector Comments Address Category Status View
REPAIR LINTELS RUSTED LINTEL WARPED SAGGING AND DETERIORATING 2ND AND 3RD LEVELS NORTH AND WEST ELEVATIONS-PERMIT. 6201 S SEELEY AVE PERIODIC FAILED View
FLAKY INTERIOR PAINT FLAKING PAINT ON WINDOW FRAMES AND SASHES. 6201 S SEELEY AVE PERIODIC FAILED View
MAINTAIN WINDOW SASH ROTTED WINDOW SASHES FRONT AND 2ND AND 3RD LEVELS. 6201 S SEELEY AVE PERIODIC FAILED View
REPUTTY WINDOW PANES WINDOW LOOSE AND MISSING PUTTY ALL ELEVATIONS. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALL-SECTIONS OF STONE MISSING FRONT NORTH ELEVATION 2015-17 CENTER, MAIN ENTRANCE STONE AROUND ENTRY FRACTURES AT MORTAR JOINTS 2015-17,2019-21. 6201 S SEELEY AVE PERIODIC FAILED View
PARAPET PARAPET WASHED OUT MORTAR JOINTS WEST ELEVATIONS PERMIT REQUIRED FOR BRICK AND LINTEL WORK. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR WINDOW SILLS WINDOW SILLS BROKEN AND WASHED OUT MORTAR 3RD LEVEL FRONT 6201-05 CENTER WEST ELEVATION. 6201 S SEELEY AVE PERIODIC FAILED View
CARPETING FRONT INTERIOR STAIRS WORN CARPET 6201-5, 1ST, 2ND. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIRS WORN CARPET LOOSE TREADS. 6201 S SEELEY AVE PERIODIC FAILED View
INT WALL/CEILING PEELING PAINT 6203 APT#2 BATHROOM AND BEDROOM CEILING AND WALLS WATER DAMAGE. 6201 S SEELEY AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS 6203 APT #2 NO SMOKE DETECTOR. 6201 S SEELEY AVE PERIODIC FAILED View
CARB MONOX DETECT IN RESID 6203 APT #2 NO CARBON MONOXIDE DETECTORS. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR DOOR FRAME, MULLION 6203-05 MAIN ENTRY VESTIBULE DOOR NOT CLOSING. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR HARDWARE 6201-05 AND 6203-05 ENTRY DOORS NOT LATCHING. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM 3 WOOD 3STORY EXTERIOR PORCH SYSTEM- PROVIDE PLANS AND PERMITS FOR PORCHES NEWER BUILT MISSING ALL REQUIRED HARDWARE-FOUNDATIONS UNKNOWN LEDGERS NAILED, BEAMS LIGHT GAUGE METAL PATCH, COLUMNS LAP JOINT 2 BOLTS. LEVELS TO STRINGER NAILED (PORCHES NOT ORIGINAL TO BUILDING) 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR LINTELS RUSTED LINTEL WARPED SAGGING AND DETERIORATING 2ND AND 3RD LEVELS NORTH AND WEST ELEVATIONS-PERMIT. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL OPEN MORTAR JOINTS AND SPAWLLING BRICKS UNDER WINDOWS AT VARIOUS LOCATIONS AT EAST ELEVATION.JCH 6201 S SEELEY AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS 1ST FLOOR NORTH AND EAST AT 2015, 6201 2ND REAR, 2015 BASEMENT NORTH.JCH 6201 S SEELEY AVE PERIODIC FAILED View
PARAPET PARAPET WASHED OUT MORTAR JOINTS WEST ELEVATIONS PERMIT REQUIRED FOR BRICK AND LINTEL WORK. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR WINDOW SILLS EAST ELEVATION 2ND FLOOR, SILL MISSING.JCH 6201 S SEELEY AVE PERIODIC FAILED View
INT WALL/CEILING PEELING PAINT 6203 APT#2 BATHROOM AND BEDROOM CEILING AND WALLS WATER DAMAGE. 6201 S SEELEY AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS 6203 APT #2 NO SMOKE DETECTOR. 6201 S SEELEY AVE PERIODIC FAILED View
CARB MONOX DETECT IN RESID 6203 APT #2 NO CARBON MONOXIDE DETECTORS. 6201 S SEELEY AVE PERIODIC FAILED View
ROACHES 6201-05 2ND, 3RD EVIDENCE OF ROACHES. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM 3 PORCHES 3 STORIES EACH, NEWER BUILT. CONDITION IS TYPICAL OF ALL 3, REQUIRED HARDWARE IS MISSING; BEAM TO COLUMN LIGHT GAGE METAL OR JUST NAILED, RIM BOARDS AND RAILS (RAILS NAILED TO BUILDING BRICK ARE LOOSE AT VARIOUS LOCATIONS) ARE JUST NAILED. STRINGERS AND LEDGERS ALL CONNECTIONS ARE INADEQUATE.2X8 JOIST ARE DOUBLED AT A SPAN OF 16'. ROOF OVER PORCHES WAS NOT REPLACED AND IS ROTTED AND MISSING HATCH COVERS.SPECIFICLY; 2019-21 PORCH 1ST THREAD IS CRACKED AND SPLIT POSING A HAZARD.RAILS AT LANDING 1ST TO 2ND DEFLECT UNDER PRESSURE. 2015-17 PORCH HAS SECTIONS OF RAILS 1ST TO 3RD FLOOR, SPANNING 8 TO 10 FEET, THESE SECTIONS DEFLECT HEAVILY UNDER PRESSURE. SUBMIT PLANS AND OBTAIN PERMIT TO BRING PORCHES INTO COMPLIANCE.JCH 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALL-SECTIONS OF STONE MISSING FRONT NORTH ELEVATION 2015-17 CENTER, MAIN ENTRANCE STONE AROUND ENTRY FRACTURES AT MORTAR JOINTS 2015-17,2019-21. 6201 S SEELEY AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# INCOMPLETE ID POSTED. 6201 S SEELEY AVE PERIODIC FAILED View
PERMIT REQUIRED - CONTRACTOR NO PERMIT ON RECORD FOR 7' WROUGHT IRON FENCE.JCH 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL OPEN MORTAR JOINTS AND SPAWLLING BRICKS UNDER WINDOWS AT VARIOUS LOCATIONS AT EAST ELEVATION.JCH 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR WINDOW SILLS EAST ELEVATION 2ND FLOOR, SILL MISSING.JCH 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM 3 PORCHES 3 STORIES EACH, NEWER BUILT. CONDITION IS TYPICAL OF ALL 3, REQUIRED HARDWARE IS MISSING; BEAM TO COLUMN LIGHT GAGE METAL OR JUST NAILED, RIM BOARDS AND RAILS (RAILS NAILED TO BUILDING BRICK ARE LOOSE AT VARIOUS LOCATIONS) ARE JUST NAILED. STRINGERS AND LEDGERS ALL CONNECTIONS ARE INADEQUATE.2X8 JOIST ARE DOUBLED AT A SPAN OF 16'. ROOF OVER PORCHES WAS NOT REPLACED AND IS ROTTED AND MISSING HATCH COVERS.SUBMIT PLANS AND OBTAIN PERMIT.SPECIFICLY; 2019-21 PORCH 1ST THREAD IS CRACKED AND SPLIT POSING A HAZARD.RAILS AT LANDING 1ST TO 2ND DEFLECT UNDER PRESSURE. 2015-17 PORCH HAS SECTIONS OF RAILS 1ST TO 3RD FLOOR, SPANNING 8 TO 10 FEET, THESE SECTIONS DEFLECT HEAVILY UNDER PRESSURE. SUBMIT PLANS AND OBTAIN PERMIT TO BRING PORCHES INTO COMPLIANCE.JCH 6201 S SEELEY AVE PERIODIC FAILED View
INT WALL/CEILING PEELING PAINT 2015W./ #1 - FRONT ROOM AND BATHROOM BROKEN AND DAMAGED WALLS AND CEILING. 6201 S SEELEY AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS 1ST FLOOR NORTH AND EAST AT 2015, 6201 2ND REAR, 2015 BASEMENT NORTH.JCH 6201 S SEELEY AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# INCOMPLETE ID POSTED. 6201 S SEELEY AVE PERIODIC FAILED View
FILE BLDG REGISTRATION NOT REGISTERED. 6201 S SEELEY AVE PERIODIC FAILED View
FIRE EXTNGSHR RECHARGE & TAG 2015W./ FOYER - FIRE EXTINGUISHER MISSING TAG. 6201 S SEELEY AVE PERIODIC FAILED View
INT WALL/CEILING PEELING PAINT 6203 APT#2 BATHROOM AND BEDROOM CEILING AND WALLS WATER DAMAGE. 6201 S SEELEY AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING- NO RESPONSE , UNVERIFIED DETECTORS. UNABLE TO VERIFY PREVIOSLY VIOLATION WRITTEN,( SEE INSPECTION # 2829475 OF 11/16/2009). 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS 2015W./ #1- SMOKE DETECTOR MISSING. 6201 S SEELEY AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# INCOMPLETE ID POSTED. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL VARIOUS LOCATIONS - BRICKS SPALLING UNDER WINDOWS, WITH OPEN MORTAR JOINTS. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS 6201 S. / TOP OF FRONT STAIRWAY - SMOKE DETECTOR BROKEN AND DISABLED. 6201 S SEELEY AVE COMPLAINT FAILED View
INT WALL/CEILING PEELING PAINT 2015W./ #1 - FRONT ROOM AND BATHROOM BROKEN AND DAMAGED WALLS AND CEILING. 6201 S SEELEY AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS 1ST FLOOR NORTH AND EAST AT 2015, 6201 2ND REAR, 2015 BASEMENT NORTH.JCH 6201 S SEELEY AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# INCOMPLETE ID POSTED. 6201 S SEELEY AVE PERIODIC FAILED View
FIRE EXTNGSHR RECHARGE & TAG 2015W./ FOYER - FIRE EXTINGUISHER MISSING TAG. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR/REPLACE SMOKE DETECTORS 2015W./ #1- SMOKE DETECTOR MISSING. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR WINDOW SILLS EAST ELEVATION,2ND ,3RD FLOOR WINDOW SILLS,MISSING ,BROKEN AND WASHED OUT MORTAR. 6201 S SEELEY AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH ELEVATION,WEST END AT 3DR FLOOR,STONE WINDOW HEADER MISSING, LOOSE BRICKS ( DANGEROUS CONDITION) OVER PUBLIC SIDEWALK. 2015-17 ,1ST FLOOR STONE WINDOW HEADER,LEANING OUT WARD OVER MAIN ENTRY WAY.EAST ELEVATION UNDER WINDOWS,SPALLING BRICKS,WASHED OUT MOTAR.MASONRY PERMIT REQUIRED. 6201 S SEELEY AVE COMPLAINT FAILED View
REPAIR LINTELS NORTH ELEVATION,RUSTY LINTELS,METAL LINTEL CAPPING WITH RUST STAINS.NORTH 3RD FLOOR WINDOW WITH MISSING STONE WINDOW HEADER,DETERIORATING LINTEL. 6201 S SEELEY AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS BUILDING ,AT VARIOUS LOCATIONS,BROKEN PAINS OR BOARDEN WINDOWS. 6201 S SEELEY AVE COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR BUILDING,7 FT. HIGH WROUTH IRON FENCE INSTALLED WITHOUT A PERMIT. 6201 S SEELEY AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCHES,3 PORCHES,3 STORIES EACH,NEWLY BUILT.CONDITION IS TYPICAL OF ALL 3,REQUIRED HARDWARE IS MISSING,BEAM TO COLUMN WITH LIGHT GAGE METAL OR JUST NAILEDC,RIM BOARDS AND RAILS (RAILS NAILED TO BUILDING ARE LOOSE AND PULLING WITH MISSDING PICKETS,STRINGERS AND LEDGERS ALL CONNECTIONS ARE INADEQUATE.2X8 JOISTS ARE DOUBLED AT A SPAN OF 16'.ROOF OVER PORCHES IS ROTTED AND MISSING HATCH COVERS.SUBMIT PLANS AND OBTAIN PERMIT.SPECIFICLY; 2019-21 PORCH 1ST TREAD IS CRACKED AND SPLIT POSING A HAZARD.RAILS AT LANDINGS 1ST TO 2ND DEFLECT UNDER LOAD.2015-17 PORCH HAS SECTION OF RAILS1ST TO 3RD FLOOR,SPANNING 8 TO 10 FEET,THESE SECTIONS DEFLECT HEAVILY UNDER PERSSURE.SUBMIT PLANS AND OBTAIN PERMIT. 6201 S SEELEY AVE COMPLAINT FAILED View
INT WALL/CEILING PEELING PAINT 2015W #1-FRONT ROOM AND BATHROOM BROKEN AND DAMAGED WALLS AND CEILING. 6201 S SEELEY AVE COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG 2015W FOYER-FIRE EXTINGUISHERT,MISSDING TAG. 6201 S SEELEY AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS 2015W-#1 SMOKE DETECTOR MISSING. 6201 S SEELEY AVE COMPLAINT FAILED View
COVER OUTLETS AND JBS 2015W #1KITCHEN AND HALLWAY ELECTRICAL COVERS,MISSING. 6201 S SEELEY AVE COMPLAINT FAILED View
FIRE EXTNGSHR RECHARGE & TAG 2015W./ FOYER - FIRE EXTINGUISHER MISSING TAG. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL NORTH AND SOUTH EXTERIOR WALLS - WASHEDC OUT MORTAR. NORTH ENTRYWAY ORNAMENT STONES AT 2019 W./ - WASHED OUT MORTAR. 6201 S SEELEY AVE PERIODIC FAILED View
PARAPET SOUTH AND WEST PARAPET WALLS - WASHED OUT MORTAR.WEST ELEVATION (SOUTH END) - BRICKS ARE SHIFTING OUT. 6201 S SEELEY AVE PERIODIC FAILED View
1HR SEP-D.U. AND REST OF BLDG SOUTH PASSAGEWAY CEILING - PLASTER HAS HOLES. 6201 S SEELEY AVE PERIODIC FAILED View
DEFECTIVE FIXTURES SOUTH EXTERIOR LIGHT FIXTURE (UNDER PORCH ) - HANGING LOOSE. 6201 S SEELEY AVE PERIODIC FAILED View
REPAIR WINDOW SILLS EAST AND WEST WINDOW SILLS - WASHED OUT MORTAR. 6201 S SEELEY AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS NORTH AND SOUTH WINDOWS - BROKEN GLASS PANE. 6201 S SEELEY AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE, UNABLE TO VERIFY DETECTOR AND INTERIOR CONDITIONS. 6201 S SEELEY AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS BROKEN WINDOWS 1ST FRONT 2016-17, 6201 #2REAR, 2203# 2REAR. 6201 S SEELEY AVE PERIODIC FAILED View
ROACHES 6201-05 2ND, 3RD EVIDENCE OF ROACHES. 6201 S SEELEY AVE PERIODIC FAILED View
FILE BLDG REGISTRATION NOT REGISTERED. 6201 S SEELEY AVE PERIODIC FAILED View
COVER OUTLETS AND JBS 2015W./#1 - KITCHEN AND HALLWAY ELECTRICAL COVERS MISSING. 6201 S SEELEY AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BLDG. - NOT REGISTERED FOR 2011. 6201 S SEELEY AVE PERIODIC FAILED View
PARAPET WEST ELEVATION,PARAPET WALL,WASHED OUT MORTAR. 6201 S SEELEY AVE COMPLAINT FAILED View
REMV OBSTR FROM DRAINAGE SYSTM SOUTH EXTERIOR FLOOR DRAIN - CLOGGED. 6201 S SEELEY AVE PERIODIC FAILED View