The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PARAPET & COPING | SPALLING MORTAR + LOOSE BRICKS AT THE SOUTH, EAST, AND WEST ELEVATION | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
FAILURE TO PERMIT ACCESS FOR ANNUAL INSPECTION 13-20-020. ATTEMPTED INSPECTION 12/16/09. STICKER LEFT ON DOOR. NO ONE CONTACTED DEPT OF BUILDINGS TO ALLOW ACCESS. TO ARRANGE INSPECTION PLEASE CALL (312) 743 - 0407. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View | |
PROVIDE CLASS A FIRE DOOR | PROVIDE FIRE RATED DOORS BETWEEN SANCTUARY AND OFFICE/DINING BUILDING. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ACCESS TO INTERIOR FOR 2019 ANNUAL INSPECTION. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
OPEN TYPE VIOLATION | PROVIDE NEW WHEEL STOPS AT EAST EXIT DOORS (PARKING LOT) CURRENTLY EXISTING WHEELSTOPS NOT EFFECTIVE PER 13.160.070. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
POST APPROVED OCCUPANCY CARD | OBTAIN AND POST OCCUPANCY CARDS FOR SANCTUARY AND DINING HALL. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | OBTAIN AND SUBMIT A STRUCTURAL ENGINEERS LETTER FOR THE STRUCTURAL STABILITY OF ROOF TRUSSES @ SANCTUARY | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
RESTORE ROOF LIVE LOADTO ORIG | REPAIR OR REPLACE BOW ROOF TRUSSES AT SANCTUARY, BOTTOM CHORDS OF TRUSSES ARE DEFECTING. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | REMOVE SLIDEBOLTS FROM EXIT DOORS AT SANCTUARY. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
SANCTUARY WALLS HAVE PANELING PROVIDE FIRE RATING ON WALLS. PER SECTION 13.84.050 | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View | |
REPAIR EXTERIOR WALL | FRONT EAST ELEVATION EXTERIOR WALL IS CONVEXED AT MIDPOINT OF WALL HIEGHT. PROVIDE ENGINEERS LETTER FOR STRUCTURAL STABILITY OF WALL. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
OPEN TYPE VIOLATION | FAILURE TO PERMIT ACCESS FOR ANNUAL INSPECTION 13-20-020. ATTEMPTED INSPECTION 07/31/2012. STICKER LEFT ON DOOR. NO ONE CONTACTED DEPT. OF BUILDINGS TO ALLOW ACCESS. TO ARRANGE INSPECTION PLEASE CALL 312-743-3610. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | REAR WEST ELEVATION AT ALLEY- EXCESSIVE WEEDS | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROVIDE PERMITS FOR TRUSS AND MASONRY REPAIRS | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
OPEN TYPE VIOLATION | FAILURE TO PERMIT ACCESS FOR ANNUAL INSPECTION 13-20-020. ATTEMPTED INSPECTION 07/31/2012 AND 3/29/13. STICKER LEFT ON DOOR. NO ONE CONTACTED DEPT. OF BUILDINGS TO ALLOW ACCESS. TO ARRANGE INSPECTION PLEASE CALL 312-743-3610. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
ARRANGE FOR INSPECTION | CALL 312-743-3562 ASK FOR INSPECTOR #653 RICH HASTINGS WEDNESDAYS BETWEEN 8:00 AND 9:00 AM. | 6850 S COTTAGE GROVE AVE | PERIODIC | PASSED | View |
ACCESS TO ROOF | ROOF | 6850 S COTTAGE GROVE AVE | PERIODIC | PASSED | View |
PARAPET | FRACTURED MASONRY AND WASHOUT MORTAR JOINTS | 6850 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMITS FOR REPAIR/REPLACEMENT OF STRUCTURAL MEMBERS (TRUSSES) REPAIR OF EAST MASONRY WALL AND ALL ASSOCIATE INTERIOR WORK AS REQUIRED INCLUDING INTERIOR PARTITIONS EXTERIOR WALL FURRING, MOLD REMEDIATION, MECHANICAL, ELECTRICAL AND PLUMBING WORK | 6850 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
PERFRM STRUCT ENGINEER REPAIRS | STRUCTURAL ENGINEER REPORT REQUIRE FOR SANCTUARY WITH POWERING BARREL ROOF ROOF TRUSSES BRACED WITH 6X6 STRUCTURAL MEMBER, 4 SUCH TRUSSES WESTERN MOST TRUSS WITH FRACTURES AT SOUTHERN END OF BOTTOM CHORD ENGINEER'S REPORT TO ALSO INCLUDE CONDITION OF ROOF FRAMING(FRAMING NOT VISIBLE DURING FIELD VISIT DUE TO PARTICLE BOARD AT UNDERSIDE PARTICLE BOARD HAS AREAS OF SIGNIFICANT MOLD STORES INDICATING SUSTAINED WATER PENETRATION ENGINEERS REPORT TO ALSO ASSESS THE CONDITION OF THE EAST EXTERIOR SANCTUARY MASONRY WALL THE TOP THIRD OF MASONRY IS OUT OF PLUMB AND TOWARDS WEST ELEVATION | 6850 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REMOVE STORAGE IN NORTH STAIRWAY OF NORTH BUILDING | 6850 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ACCESS TO INTERIOR FOR 2016 ANNUAL INSPECTION. CALL 312 743 0407 FOR INSPECTION. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
ARRANGE FOR INSPECTION | CALL 312-743-3562 ASK FOR INSPECTOR #653 RICH HASTINGS ,WEDNESDAY BETWEEN 8:00 AND 9:00 AM | 6850 S COTTAGE GROVE AVE | PERIODIC | PASSED | View |
ACCESS TO ROOF | ROOF | 6850 S COTTAGE GROVE AVE | PERIODIC | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ACCESS TO INTERIOR FOR 2017 ANNUAL INSPECTION. CALL 312 743-0407 FOR INSPECTION. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ACCESS TO INTERIOR FOR 2018 ANNUAL INSPECTION. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY, ACTIVE COURT CASE | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
PARAPET | EAST ELEVATION PARAPET AND LEANING TOWARDS ROOF. REPAIRS REQUIRE PERMIT. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
PROTECT SIDEWALK DURING CONST | INSTALL CANOPY AT SIDEWALK DURING MASONRY REPAIR WORK. PERMIT REQUIRED. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WARPED AND DAMAGED VINYL SIDING AT ADDITION NEAR PARKING LOT. | 6850 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |