ADD RECEPTACLES | D&H INSTALL ADDITIONAL RECEPTACLES TO EASE ELECTRICAL OUTLETS | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | THERE ARE AREAS OF DANAGED DRYWALL CEILINGS / WALLS.SECTION 14X=-3-304.3 | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | THE WINDOWS AT THE NORTH AND SOUTH ELEVATIONS HAVE METAL BARS PREVENTING EMERGENCY EGRESS. DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.1.2 | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View | |
NO GASOLINE(LPG) STORAGE | THERE ARE, IN THIS SINGLE FAMILY HOME, PROPANE TANKS STORED INSIDE AS WELL AS SEVERAL GASOLINE POWERED MACHINES. DANGEROUS AND HAZARDOUS.SECTION 14B-33-3317.1 AND 14X-5-505.1.2.1 | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | THIS HOUSE HAS NO CARBON MONOXIDE DETECTOR. DANGEROUS AND HAZARDOUS.SECTION 14X-5-504.9 | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | THIS HOUSE HAS NO SMOKE DETECTORS. DANGEROUS AND HAZARDOUS. SECTION 14X-5-504.8 | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | THE FURNACE AND WATER HEATER ARE LOCATED, OPEN, IN THE KITCHEN AREA. THERE IS NO FIRE RESISTIVE ENCLOSURE WITYH A VENTED, FIRE RATED DOOR. PERMIT REQUIRED. DANGEROUS AND HAZARDOUS.SECTION 14B-5-509 | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | THERE ARE NUMEROUS AREAS WHERE THE FINISHED VINYL FLOORING IS MISSING; INCLUDING THE ENTIRE KITCHEN FLOOR (EXPOSED PLYWOOD SUBFLOOR).SECTION 14X-3-304.4 | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | THE KITCHEN FLOOR IS COMPRISED OF FILTHY PLYWOOD SUB FLOORING BECAUSE THE FINISHED FLOORING IS MISSING. ALSO, THE INTERIOR OF THIS HOUSE IS FILLED WITH EXCESSIVE AMOUNTS OF JUNK / DEBRIS.UNSANITARY CONDITION.SECTION 14X=1=103 | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | BATHTUB LOCATED IN BATHROOM IS SEVERLY DISCOLORED AND RUSTED AND NOT PROPERLY GLAZED | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | D&H SUPPORT LOOSE FIXTURE IN BEDROOM | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FITTINGS | WATER PIPING AT MOP SINK IS NOT PROPERLY INSTALLED IN REAR LAUNDRY ROOM DANGEROUS AND HAZARDOUS | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | UNAPPROVED WATTER FLEXIBLE LINES ATTACHED TO HOT WATER TANK ON HOT AND COLD LOCATED IN REAR LAUNDRY AREA DANGEROUS AND HAZARDOUS | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View | |
INSTALL VENT PIPE FOR TRAP | NO VENTING SYSTEM CONNECTION ON MOP SINK THAT IS INSTALLED IN REAR LAUNDRY AREA | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
OBTAIN ELECTRICAL PERMIT AND LICENSED ELECTRICIAN TO PERFOR WORK | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View | |
REPLACE DEFECTIVE WASTE PIPING | WASTE CONNECTION AT LAUNDRY WASHER WASTE CONNECTION IS NOT PROPERLY INSTLLED IN REAR LAUNDRY ROOM | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
WORKING SPACE | D&H PROVIDE AT LEAST 3 FEET CLEARANCE AROUND ELECTRICAL SERVICE AND DISTRIBUTION EQUIPMENT | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
OPEN | NO DIELETRICK UNION CONNECTIONS ARE INSTALLED ON HOT WATER TANK WATER CONNECTIONS IN REAR LAUNDRY AREA DANGEROUS AND HAZARDOUS 18.29.501.4 AND 18.29.605.2.1 | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
SUPPORT OUTLET AND BOX | D&H SUPPORT ELECTRICAL CONDUIT INTERIOR AND EXTERIOR OF BUILDING | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | DEFECTIVE KITCHEN FAUCET IS LEAKING LOCATED IN KITCHEN AT SINK | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | NO FAUCET IN INSTALLED AT MOP SINK IN LAUNDRY AREA POTABLE WATER LINES DANGEROUS AND HAZARDOUS | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FITTINGS | WATER PIPING AT LUNDRY CONNECTIONS IS NOT PROPERLY INSTALLED IN REAR LAUNDRY ROOM DANGEROUS AND HAZARDOUS | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | D&H DEFECTIVE SERVICE RISER NEEDS SUPPORTING | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
PRV BALLCOCK,VB,OR AIR GAP | NO VACUUM BREAKER AT HOSE BIBB LOCATED AT NORTH ELEVATION OF BUILDING LOCATION DANGEROUDS AND HAZARDOUS | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |
PANEL SCHEDULES | D&H PROVIDE DETAILED AND LEGIBLE PANEL SCHEDULE | 6951 S HERMITAGE AVE | COMPLAINT | FAILED | View |