The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR/REPLACE SMOKE DETECTORS | INTERIOR OF BUILDING - ENTRY STAIR - TOP OF CEILING /SMOKE DETECTOR - LOW BATTERY INDICATION AT TIME OF INSPECTION. | 1941 W 59TH ST | COMPLAINT | FAILED | View |
PROVIDE | INTERIOR OF BUILDING - APT 1A /KITCHEN CABINETS, SINK, AND COUNTER SPACE - MISSING. (SEC | 1941 W 59TH ST | COMPLAINT | FAILED | View |
INSECTS | INTERIOR OF BUILDING - APT 1 - AROUND BASEBOARDS /SMALL INSECTS - PRESENT. | 1941 W 59TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 1941 W 59TH ST | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED FROM 2009 THRU 2016. | 1941 W 59TH ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | FRONT METAL FENCE 6 FEET HIGH AND REAR WOOD PERIMETER FENCE 6 FEET HIGH - CONSTRUCTED WITHOUT OBTAINING A PERMIT. | 1941 W 59TH ST | COMPLAINT | FAILED | View |
REPAIR FENCE | REAR ELEVATION/ WOOD FENCE - DETACHED SECTIONS. | 1941 W 59TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2-STORY WOOD PORCH/ DOUBLE 2X12 HEADER - SEPARATING FROM EACH OTHER AND ONLY FASTENED WITH SCREWS ONLY; SPLIT AND SEVERLEY DRY ROTTED. RAILINGS - LOOSE, PULLING AND SOME ARE ONLY NAILED TO COLUMNS. DECKBOARDS - LOOSE, BROKEN AND SEVERELY DRY ROTTED. TREADS - LOOSE AND DRY ROTTED. MOST RAILINGS, HEADER BEAMS, TREADS, DECKBOARDS AND SOME COLUMNS - SEVERELY DRY ROTTED.PLANS AND PERMIT REQUIRED FOR REAR PORCH REPAIRS. | 1941 W 59TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S I.D SIGN POSTED. | 1941 W 59TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH ELEVATION / 3 STORY WOOD PORCH / EASTERN 6X6 COLUMN - BOWING. STAIR RISERS AT 3RD FLOOR STAIRS - CRACKED AND TIPPED OUTWARD. RAILING 4X4 POSTS - NOTCHED AROUND STRINGERS AND END JOISTS. GUARDRAIL AT 3RD FLOOR AND 1ST FLOOR HANDRAIL - MOVES WHEN SHAKEN. SOME STEEL HARDWARE - RUSTED. SOME 3RD FLOOR DECKING - ROTTING AND CRACKING. DECKING - SEPERATING ON JOIST CENTERS. PERMIT REQUIRED FOR ALL DECK REPAIRS. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 1941 W 59TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | BUILDING / FRONT ENTRY DOOR - DUCT TAPE INSTALLED OVER DOOR LOCK. DOOR IS UNSECURE AND CAN BE EASILY ACCESIBLE. | 1941 W 59TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH ELEVATION / 3 STORY WOOD PORCH / EASTERN 6X6 COLUMN - BOWING. STAIR RISERS AT 3RD FLOOR STAIRS - CRACKED AND TIPPED OUTWARD. RAILING 4X4 POSTS - NOTCHED AROUND STRINGERS AND END JOISTS. GUARDRAIL AT 3RD FLOOR AND 1ST FLOOR HANDRAIL - MOVES WHEN SHAKEN. SOME STEEL HARDWARE - RUSTED. SOME 3RD FLOOR DECKING - ROTTING AND CRACKING. DECKING - SEPERATING ON JOIST CENTERS. PERMIT REQUIRED FOR ALL DECK REPAIRS. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 1941 W 59TH ST | COMPLAINT | CLOSED | View |
REPAIR/REPLACE SMOKE DETECTORS | APT. - 3A AND FRONT INTERIOR STAIRWAY / SMOKE DETECTORS - LOWA BATTERY CHIRPING AT TIME OF INSPECTION. | 1941 W 59TH ST | COMPLAINT | CLOSED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FOR 2017. | 1941 W 59TH ST | COMPLAINT | FAILED | View |