The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INSTALL DOOR VIEWING DEVICE | ALL APT MISSING VIEWING DEVICE | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH COLUMNS ERECTED ON SERVICE WALK.JOIST NAILED TO HEADER.LEDGER BOARD NAILED.COLUMNS 1/2 LAP 16" WITH 2 BOLTS.STRINGERS NOT DOUBLE..2X8 JOIST OVER SPAN.GUARD RAILS AND STRINGERS NAILED TO COLUMNS ,HEADERS AND WALL .GUARD RAILS SECTION OVER SPAN AND GUARD RAILS LOOSE. TOP LANDING NOT STABLE. PLANS AND PERMIT REQUIRED FOR REPAIRS TO FRONT PORCH | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | REAR BUILDING.ROOM TEMPERATURE-43F.HEATING SYSTEM IS OFF AT TIME OF INSPECTION,NO HEAT PROVIDED. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | REAR BUILDING.FURNACE -OUT OF SERVICE AT TIME OF INSPECTION. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | REAR BUILDING.MISSING SMOKE DETECTOR. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | REAR BUILDING.MISSING CARBON MONOXIDE DETECTOR. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | REAR BUILDING.USING PORTABLE HEATING EQUIPMENT,ELECTRIC SPACE HEATERS AS HEATING DEVICE. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | REAR BUILDING.HOT WATER PIPES-FROZEN AND BUSTED,NO HOT WATER FURNISHED. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
PROVIDE COLD WATER TO FICTURES | REAR BUILDING.COLD WATER PIPES-FROZEN AND BUSTED,COLD WATER NOT FURNISHED. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | FRONT BUILDING,ENCLOSE PORCH AND BUILDING AREA; JUNK AND DEBRIS. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP ON BUILDING. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | POST ADDRESS ON BUILDING. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT BUILDING,HAND RAILS LOOSE,NO FOOTING,DECK JOIST PULLING AWAY FROM SUPPORT,STRINGER WOOD SPLIT,GUARD RAILS LOOSE [SUBMIT PERMITS FOR REPAIRS]. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR BUILDING, WEST STAIRS; TREADSAND STRINGER WOOD BROKEN AND SPLIT. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | REAR BUILDING,WEST BASEMENT EXTERIOR DOOR; DON'T CLOSE. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | REAR BUILDING,WINDOW FRAMES; ROTTED BEHIND METAL CAPPING. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | REAR BUILDING,CHIMNEY CAPPING; MISSING. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR FRONT AND REAR BUILDING. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | REAR BUILDING.WINDOW FRAMES-CRACKS,DRAFTY WINDOWS,AIR SEEPAGE. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH ELEVATION -STAIRS GRADE TO BASEMENT NO HAND RAIL . | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER | SOUTH ELEVATION- GUTTER SECTION MISSING | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER ID NOT POSTED. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | ATTIC MISSING DETECTOR | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR PORCH 2ND FLOOR WASHER AND DRYER. | 8806 S ESCANABA AVE | COMPLAINT | FAILED | View |