Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLCE WINDOW PANES, PLEXGLAS | 1548 W / 1556 W / FRONT ENTRY DOORS MISSING WINDOW PANES.1558 W / 1554 W / FRONT ENTRY DOORS WITH BROKEN WINDOW PANES. | 1550 W JUNEWAY TER | COMPLAINT | FAILED | View |
PARAPET | ALL ELEVATIONS PARAPET WALLS ERODED MORTAR JOINTS, NORTH ELEVATION SKIM COAT CRUMBLING. | 1550 W JUNEWAY TER | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FOUR , 3 STORY PORCHES, 4X6 METAL BRACKETS WITH ONE BOLT SUPPORTING ALL CONNECTIONS.6X6 COLUMNS LAP JOINTS SEPERATING. 6X6 COLUMNS REST ON SQUARE CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 1550 W JUNEWAY TER | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | MOST LINTELS REPLACED, NO PERMIT OBTAINED. | 1550 W JUNEWAY TER | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 1550 W JUNEWAY TER | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE TO MOST APARTMENTS IN ORDER TO VERIFY DETECTORS. | 1550 W JUNEWAY TER | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH #1550 - FOUNDATION STATUS UNKNOWN; UNDERSIZED 4X4 COLUMNS; LOOSE RAILS AT 3RD FLOOR; SUPPORT MISSING UNDERNEATH WINDERS; NEW 4X6 COLUMNS, STRINGERS, TREADS AND RISERS, AND SISTERED 2X8 JOISTS. PERMIT #100484121 ISSUED 4/10/2013. | 1550 W JUNEWAY TER | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | RECENTLY REPAIRED REAR PORCHES PER PERMIT #100484121 (ISSUED 4/10/2013). PLANS AND ORIGINAL PERMIT NOT AVAILABLE FOR INSPECTOR'S REVIEW AT TIME OF INSPECTION. SUBJECT TO FIELD INSPECTION AND FINAL APPROVAL. | 1550 W JUNEWAY TER | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | #1550-3RD FLOOR - CARBON MONOXIDE DETECTOR - MISSING | 1550 W JUNEWAY TER | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | #1550-3RD FLOOR - STORM WINDOWS MISSING IN SOME LOCATIONS | 1550 W JUNEWAY TER | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO INSPECT ALL INTERIORS, APARTMENTS, STAIRWELLS, BASEMENT, REAR PREMISES, AND REAR PORCHES. UNVERIFIED DETECTORS AND OCCUPANCY. | 1550 W JUNEWAY TER | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 1550 W. / APARTMENT # 3D - ALL WINDOWS - SEVERE AIR SEEPAGE. | 1550 W JUNEWAY TER | COMPLAINT | FAILED | View |