Chicago Building Violations Data: 14 Violations
Violation Inspector Comments Address Category Status View
MAINTAIN WINDOW ALL ELEVATIONS, WINDOW FRAMES AND SILLS SEVERELY ROTTING. 3530 W MCLEAN AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION, 1ST FLOOR - SILL PLATE AT 1ST FLOOR LINE EXPOSED AND ROTTING. 3530 W MCLEAN AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS 1. SOUTH ELEVATION, 1ST FLOOR - BROKEN WINDOW PANE. 2. WEST ELEVATION, 2ND FLOOR BROKEN WINDOW PANE. 3530 W MCLEAN AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR SOUTH ELEVATION, FRONT WOOD AND BRICK STAIR SYSTEM FROM GROUND TO 1ST FLOOR:1. STRINGER FOUNDATION, 1ST STEP - CONCRETE CRACKED AND SPALLED.2. BRICK PILASTERS - OPEN JOINTS WITH SHIFTING BRICK. 3. DECK BOARDS WEAK, ROTTING AND BUCKLING.4. DECK JOIST UNDERSIZED 2X4S AND 2X6 JOIST SPAN 10 FT. 3530 W MCLEAN AVE COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR WEST ELEVATION, FENCE 6 FT. - NO PERMIT ON FILE FOR FENCE OVER 5 FT. 3530 W MCLEAN AVE COMPLAINT FAILED View
REPLACE D&H PORCH NORTH ELEVATION, 2 STORY WOOD PORCH SYSTEM PARTIALLY ENCLOSED ON WEST SIDE:1. COLUMNS RESTING ON CONCRETE WITHOUT ANCHORS, FOUNDATIONS UNKNOW.2. 1ST AND 2ND FLOOR BEAMS AND COLUMNS SCABBED.3. 1ST FLOOR 2X6 DECK JOIST SCABBED. 4. ALL RIM JOIST SEVERELY ROTTING. 5. DECK BOARDS AT 1ST AND 2ND FLOOR SEVERELY ROTTING AND BUCKLING. EXTREAMLY WEAK. 6. ALL HANDRAIL AND GUARDRAIL TOE-NAILED CONNECTIONS PULLING AND WEAK. GUARDRAIL HEIGHT 2 FT - 7 INCHES. GUARDRAIL MISSING AT EAST END OF BOTH 1ST AND 2ND FLOOR. DANGEROUS AND HAZARDOUS. *PLANS AND PERMIT REQUIRED FOR REPAIRS AND REPLACEMENT OF PORCH STRUCTURAL MEMBERS. 3530 W MCLEAN AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR SOUTH ELEVATION, FRONT WOOD AND BRICK STAIR SYSTEM FROM GROUND TO 1ST FLOOR:1. STRINGER FOUNDATION, 1ST STEP - CONCRETE CRACKED AND SPALLED.2. BRICK PILASTERS - OPEN JOINTS WITH SHIFTING BRICK. 3. DECK BOARDS WEAK, ROTTING AND BUCKLING.4. DECK JOIST UNDERSIZED 2X4S AND 2X6 JOIST SPAN 10 FT. 3530 W MCLEAN AVE COMPLAINT PASSED View
PERMIT REQUIRED - CONTRACTOR WEST ELEVATION, FENCE 6 FT. - NO PERMIT ON FILE FOR FENCE OVER 5 FT. 3530 W MCLEAN AVE COMPLAINT PASSED View
MAINTAIN WINDOW ALL ELEVATIONS, WINDOW FRAMES AND SILLS SEVERELY ROTTING. 3530 W MCLEAN AVE COMPLAINT PASSED View
REPLACE D&H PORCH NORTH ELEVATION, 2 STORY WOOD PORCH SYSTEM PARTIALLY ENCLOSED ON WEST SIDE:1. COLUMNS RESTING ON CONCRETE WITHOUT ANCHORS, FOUNDATIONS UNKNOW.2. 1ST AND 2ND FLOOR BEAMS AND COLUMNS SCABBED.3. 1ST FLOOR 2X6 DECK JOIST SCABBED. 4. ALL RIM JOIST SEVERELY ROTTING. 5. DECK BOARDS AT 1ST AND 2ND FLOOR SEVERELY ROTTING AND BUCKLING. EXTREAMLY WEAK. 6. ALL HANDRAIL AND GUARDRAIL TOE-NAILED CONNECTIONS PULLING AND WEAK. GUARDRAIL HEIGHT 2 FT - 7 INCHES. GUARDRAIL MISSING AT EAST END OF BOTH 1ST AND 2ND FLOOR. DANGEROUS AND HAZARDOUS. *PLANS AND PERMIT REQUIRED FOR REPAIRS AND REPLACEMENT OF PORCH STRUCTURAL MEMBERS. 3530 W MCLEAN AVE COMPLAINT PASSED View
REPAIR EXTERIOR WALL SOUTH ELEVATION, 1ST FLOOR - SILL PLATE AT 1ST FLOOR LINE EXPOSED AND ROTTING. 3530 W MCLEAN AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE TO 1ST AND 2ND FLOOR UNITS - UNVERIFIED DETECTORS AND CONDITIONS. 3530 W MCLEAN AVE COMPLAINT PASSED View
REPLCE WINDOW PANES, PLEXGLAS 1. SOUTH ELEVATION, 1ST FLOOR - BROKEN WINDOW PANE. 2. WEST ELEVATION, 2ND FLOOR BROKEN WINDOW PANE. 3530 W MCLEAN AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE TO 1ST AND 2ND FLOOR UNITS - UNVERIFIED DETECTORS AND CONDITIONS. 3530 W MCLEAN AVE COMPLAINT FAILED View