Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
DEBRIS, EXCESSIVE | (SR.#802319603)FRONT YARD-USED APPLIANCES AND JUNK | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | APT.1-MISSING CARBON MONOXIDE DETECTORS. | 2705 S KOSTNER AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT PORCH-NORTH STRINGER IS ROTTED. UNDERSIZED 2X6 JOISTS FOR A 10 FEET 7INCHES SPAN. JOISTS ARE SPACED GREATER THAN 16 INCHES APART; SPACING IS INCONSISTENT. NORTH HAND RAIL IS LOOSE. 19INCH GAP FROM THE BOTTOM OF HAND RAILS TO THE TOP OF TREADS. NORTH GUARD RAIL IS BROKEN. IMPROPER CONNECTIONS-MOST MEMBERS ARE ONLY TOE NAILED TOGETHER. PEELING PAINT. REAR ENCLOSED PORCH-PICKETS ARE SPACED AT 6 1/2 INCHES APART. BEAM IS ONLY TOE NAILED AT THE COLUMN CONNECTION. PERMIT IS REQUIRED FOR ALL PORCH REPAIRS. | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | REAR AT (1)-BROKEN WINDOW PANE | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW SASH | APT.1;NORTH BEDROOM-WINDOW SASH IS LOOSE | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW | ALL ELEVATIONS-WORN WINDOW FRAMES | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
WINDOW REPAIR FOR AIR SEEPAGE | APT.1; NORTH AND SOUTH WINDOW FRAMES-GAPS; DRAFTY AND AIR SEEPAGE. | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
REPAIR WINDOW SILLS | ALL ELEVATIONS-WORN WINDOW SILLS. | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
PERMIT REQUIRED - CONTRACTOR | SOUTH AND NORTH-WINDOW OPENINGS ARE ALTERED; REDUCED IN SIZE OR ELIMINATED COMPLETELY. | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
REPAIR EAVES | FRONT AND REAR WORN EAVES | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | SOUTH AND EAST-SIDING IS LOOSE, TORN AND BUCKLED UP. | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
CHIMNEY CAPPING | MISSING CHIMNEY CAP. | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | REAR ENCLOSED PORCH AND APT.1-MISSING SMOKE DETECTORS | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | BASEMENT AND ATTIC-NO RESPONSE, UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | REAR ENCLOSED PORCH EXCESSIVE AMOUNT OF PERSONAL ITEMS STORED ON THE LANDINGS. | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | APT.1-MISSING CARBON MONOXIDE DETECTORS. | 2705 S KOSTNER AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | FRONT EXTERIOR STAIRS - LEDGER BEAM ATTACHED TO EXTERIOR WALL WITH NAILS ONLY.4" X 4" COLUMNS SET ON RETAINING WALL - FOUNDATION STATUS UNKNOWN. STRINGER IS ROTTEN. STRINGERS ATTACHED TO COLUMNS WITH NAILS ONLY. DECK JOISTS ARE TOE-NAILED TO RIM JOISTS. UNDERSIZED 2" X 6" DECK LOISTS SPAN 10' 7".RAIL SECTIONS ARE ONLY 36" HIGH. NORTH RAIL SECTION LOOSE. PERMIT ONLY REQUIRED TO REPLACE FRONT EXTERIOR STAIRS. | 2705 S KOSTNER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO HABLA INGLISE. UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. | 2705 S KOSTNER AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | ATTIC AND BASEMENT - REMOVED ALL PARTITIONS AND FIXTURES INCLUDING PLUMBING AND ELECTRIC INSTALLED WITHOUT A PERMIT | 2705 S KOSTNER AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALTERATIONS TO BASMENT AND ATTIC OR RESTORE TO THEIR ORIGINAL CONDITIONS. | 2705 S KOSTNER AVE | COMPLAINT | PASSED | View |
PARTITIONS, N/L/B - BASEMENT | BASEMENT PARTITION WALLS - NOT 1 HOUR | 2705 S KOSTNER AVE | COMPLAINT | PASSED | View |
BASEMENT, DISCONTINUE | BASEMENT HAS DWELLING UNIT. | 2705 S KOSTNER AVE | COMPLAINT | PASSED | View |
CEILING HEIGHT - 7' | ATTIC CEILING HEIGHT NOT 7'. | 2705 S KOSTNER AVE | COMPLAINT | PASSED | View |
PARTITIONS,N/L/B | ATTIC PARTITIONS NOT 1 HOUR. | 2705 S KOSTNER AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING / NO OWNER'S ID SIGN POSTED. | 2705 S KOSTNER AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | ATTIC APARTMENT-MISSING CARBON MONOXIDE DETECTOR. | 2705 S KOSTNER AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO ATTIC OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 2705 S KOSTNER AVE | COMPLAINT | FAILED | View |
EGRESS | ATTIC DWELLING UNIT-ONLY ONE EGRESS EXISTS (IN THE REAR). | 2705 S KOSTNER AVE | COMPLAINT | FAILED | View |
INSECTS | BUILDING -BED BUG INFESTATION THROUGHOUT.PROPERTY MUST BE EFFECTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT, BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. (ATTIC APARTMENT). | 2705 S KOSTNER AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT - CEILING HEIGHT NOT 7' | 2705 S KOSTNER AVE | COMPLAINT | PASSED | View |
ATTIC, DISCONTINUE | ATTIC IS USED AS DWELLING UNIT. | 2705 S KOSTNER AVE | COMPLAINT | PASSED | View |
REPAIR/REPLACE SMOKE DETECTORS | ATTIC APARTMENT / SMOKE DETECTOR / OUT OF SERVICE AT TIME OF INSPECTION-WITH LOW BATTERY. | 2705 S KOSTNER AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC ) INSTALLED IN THE ATTIC WITHOUT A PERMIT. | 2705 S KOSTNER AVE | COMPLAINT | FAILED | View |