The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPLACE D&H PORCH | REAR PORCH ... 2 LEVELS. THE 2 SUPPORT COLUMNS ARE A 4"4" AND A 6"X^" ... BOTH COLUMS ARE SUBSTANTIALLY ROTTED AT THE BASE AND AT THE RIM BEAM CONNECTIONS. THE BANISTERS VARY IN HEIGHT AND ARE BELOW REQUIRED HEIGHT (VARY FROM 28" TO 32"). THE CULMNS HAVE NO INDEPENDENT FOOTINGS. THE STAIR TREADS ARE LOOSR. ALL THE NAILED JOINTS ARE FAILING. THE IS TOUNGE AND GROVE DECKING IN PLACE THAT HAS BECOME DRY ROTTED. THIS PORCH IS IN DANGEROUS AND HAZARDOUS CONDITION.FRONT PORCH. DRY ROTTED TOUNGE AND GROVE DECKING. THE FLOOR JOISTS ARE GREATLY OVERSPANNED (2"X6") BOARDS SPANNING 16 FEET. THE BANISTERS ARE TOO LOW AT 30". THE STAIT TREADS ARE LOOSE. ALL THE NAILED JOINTS ARE FAILING. THIS PORCH IS IN UNSAFE CONDITION. BOTH PORCHES ARE WITHOUT JOIST HANGERS. FOR BOTH PORCHES ... PLANS AND PERMIT ARE REQUIRED. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | 1ST FLOOR UNIT ... WATER LEAKS AT TOILET AQND BATHROOM SINK. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST FLOOR UNIT ... LOOSE VINYL TILES ... KITCHEN. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | REAR FOUNDATION WALL ABOVE GRADE ... EXCESSIVELY ERODED BRICK MORTAR. BELOW GRADE IN BASEMENT THERE ARE SEVERAL AREAS OF SEVERE WAER PENETRATION VIA GROUNDWATER SEEPAGE. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
STOP SMOKE, NOXIOUS ODORS | BASEMENT ... STRONG ODOR OF SEWER GAS. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 2CD FLLOR ... KITCHEN CABINETS ARE LOOSE / DETACHED FROM WALL. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | 2 FRONT DOORS ... THE MAIN DOOR AND THE STRORM DOOR HAVE BO LOCK HAEDWAQRE. THERE IS NO WAY TO INSURE BUILDING SECURITY. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 1ST FLOOR APARTMENT- USING GAS COOKING STOVE AS HEATING DEVICE. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 1ST FLOOR APARTMENT- FRONT ROOM 52, BEDROOM 59. HEATING SYSTEM IS ON AT TIME OF INSPECTION- HEAT IS INSUFFICIENT. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION - 1ST FLOOR - BROKEN GLASS PANE. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
PRV CAST IRON COVER FOR BASIN | REAR YARD CATCH BASIN - COVERED WITH PLYWOOD. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT ONE STORY PORCH: TREADS ARE 9-3/8" DEEP; RAILINGS HAVE A BROKEN PICKET. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS AND LEVELS - MISSING AND TORN WINDOW SCREENS. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION - MISSING AND TORN WINDOW SCREENS. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | 1ST AND 2ND FLOOR APARTMENTS, KITCHEN AND INTERIOR HALLWAY - MISSING OR TORN TILES AND SOFT SPOTS ON 1ST FLOOR KITCHEN. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY - MISSING SMO0KE DETECTOR. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | 1ST FLOOR FRONT BEDROOM CEILING AND WALL - PEELING PAINT AND BUCKLING PLASTER. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT ONE STORY PORCH: TREADS ARE 9-3/8" DEEP; RAILINGS HAVE A BROKEN PICKET. | 5747 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS AND LEVELS - MISSING AND TORN WINDOW SCREENS. | 5747 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION - 1ST FLOOR - BROKEN GLASS PANE. | 5747 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | EAST ELEVATION - MISSING AND TORN WINDOW SCREENS. | 5747 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
FLOOR, KIT & BATH NON-ABSORB | 1ST AND 2ND FLOOR APARTMENTS, KITCHEN AND INTERIOR HALLWAY - MISSING OR TORN TILES AND SOFT SPOTS ON 1ST FLOOR KITCHEN. | 5747 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY - MISSING SMO0KE DETECTOR. | 5747 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
STOP LEAKING WATER | 1ST FLOOR BATHROOM CELING - WATER LEAK. | 5747 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
INT WALL/CEILING PEELING PAINT | 1ST FLOOR FRONT BEDROOM CEILING AND WALL - PEELING PAINT AND BUCKLING PLASTER. | 5747 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
PRV CAST IRON COVER FOR BASIN | REAR YARD CATCH BASIN - COVERED WITH PLYWOOD. | 5747 S HERMITAGE AVE | COMPLAINT | CLOSED | View |
STOP LEAKING WATER | 1ST FLOOR BATHROOM CELING - WATER LEAK. | 5747 S HERMITAGE AVE | COMPLAINT | FAILED | View |