Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 4:02 PM
PIN: 26062230340000
Property Address: 9027 S EXCHANGE AVE
City - Zip: CHICAGO - 60617
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70100
2023 Tax District: 70002
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 16 Violations
Violation Inspector Comments Address Category Status View
STOP/REMOVE NUISANCE SOUTHEAST YARD - OVERGROWN TREES. 9027 S EXCHANGE AVE COMPLAINT FAILED View
CHIMNEY SOUTH MIDDLE CHIMNEY - MISSING AND SPALLING BRICKS WITH WASHED OUT MORTAR. 9027 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR COPING SOUTH AND WEST COPING - WASHED OUT MORTAR WITH LOOSE AND MISSING SECTIONS. 9027 S EXCHANGE AVE COMPLAINT FAILED View
CHIMNEY CAPPING SOUTHEAST AND SOUTHWEST CHIMNEYS - CAPS MISSING. 9027 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR CORNICE WEST CORNICE - WASHED OUT MORTAR. 9027 S EXCHANGE AVE COMPLAINT FAILED View
PARAPET SOUTH - MIDDLE AND EAST PARAPETS - WASHED OUT MORTAR. 9027 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR SCREENS WEST - WINDOW SCREENS - RIPPED. 9027 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST EXTERIOR WALL - SPALLING BRICKS , 3RD FLOOR UNDER WINDOW LARGE HOLE IN WALL 6'' X 4''. 9027 S EXCHANGE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS WEST BAY AT 2ND - WINDOW - CRACKED PANE. 9027 S EXCHANGE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FRONT INTERIOR STAIRWAY AT 3RD - SMOKE DETECTOR - MISSING. 9027 S EXCHANGE AVE COMPLAINT FAILED View
TENANT ACCESS TO SERVICE TENANTS - NO ACCESS TO BASEMENT ELECTRICAL SERVICE PANELS. 9027 S EXCHANGE AVE COMPLAINT FAILED View
MICE/RODENTS 3RD FLOOR TENANT - KITCHEN AND BATHROOM - MICE. 9027 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING 3RD FLOOR TENANT - KITCHEN - WALL BEHIND KITCHEN BASE CABINET - HOLES. 9027 S EXCHANGE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WATER PIPING 3RD FLOOR TENANT - KITCHEN AND BATHROOM WATER PRESSURE - LOW. 9027 S EXCHANGE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION BUILDING INTERIOR - BASEMENT , 1ST , AND 2ND FLOOR APARTMENTS - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT ALL INTERIOR STAIRWAYS. 9027 S EXCHANGE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR 3 STORY OPEN WOOD PORCH - SPLIT AND ROTTED COLUMNS ERECTED ON CONCRETE SLABS AND BLOCKS - FOUNDATION STATUS UNKNOWN. SOME COLUMNS STACKED , OTHER COLUMNS WITH ONLY 6'' TO 8'' LAP FOR SPLICING. ROTTED COLUMNS AND ROOF BEAMS WITH 2 X 6 PIECES SCABBED FOR SUPPORT. BEAMS ONLY NAILED TO COLUMNS. FIRE CUTS AT BEAMS AND COLUMNS PULLING AWAY AND ONLY NAILED. UNDERSIZED 2 X 8 DECK JOISTS OVERSPANNED AT 11' 8'' . DECK JOISTS ONLY NAILED TO RIM JOISTS. JOISTS SPACED 16'' TO 36'' ON CENTERS. SPLIT STRINGERS PULLING AWAY FROM HEADER JOISTS AND ONLY NAILED . DECKING - WORN , LOOSE AND ROTTED - 3'' X 6'' HOLE IN DECKING AT 1ST BY ENTRY DOOR. TREADS - LOOSE AND WORN. HAND AND GUARDRAILS LOOSE WITH LOOSE PICKETS. PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. 9027 S EXCHANGE AVE COMPLAINT FAILED View