The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INT WALL/CEILING CHIP PLASTER | INTERIOR STAIRWAY: HOLES IN PLASTER WALL | 1725 E 86TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP | 1725 E 86TH ST | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING-ALL YEARS | 1725 E 86TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION: SPALLING BRICKS, OPEN MORTAR JOINTS, MISSING BRICKS | 1725 E 86TH ST | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | EXTERIOR WOOD PEELING AND FLAKING PAINT | 1725 E 86TH ST | COMPLAINT | FAILED | View |
DEMO DEBRIS | REAR: CONSTRUCTION DEBRIS IN YARD | 1725 E 86TH ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR: OVERGROWN DEAD TREE, LEANING ON TOP OF GARAGE | 1725 E 86TH ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRWAY: MISSING HANDRAIL | 1725 E 86TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH: FOUNDATION IMPROPER CONCRETE POURED AROUND COLUMN; LEDGER SCAB WOOD, 2ND FLOOR, NOT NOTCHED INTO COLUMN ; IMPROPER CONNECTION, LEDGER UNDERSIZED 2X6 ROTTED JOIST @ 3RD FLOOR, SCAB WOOD, ROTTED WOOD, NO JOIST HANGER UNDERNEATH LANDING, JOIST NOT 16OC; BEAM BUTT-JOINTED TO COLUMN, 3RD FLOOR (IMPROPER CONNECTION); BEAM 2X6 LOOKOUTS @ 2ST AND 2ND FLOOR & OPEN POCKETS; COLUMN BOLTS TOO SMALL AND DAMAGED (SPLIT); HANDRAILS TOO SHORT, NAIL STICKING OUT AND CONNECTED TO BUILDING WITH ONE OR TWOO DRYWALL SCREWS (TOO STEEP); SUBMIT PLANS & PERMIT FOR NEWLY CONSTRUCTED PORCH DESIGN AND STABILITY QUESTIONABLE | 1725 E 86TH ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROVIDE PLANS & PERMIT FOR NEWLY CONSTRUCTED PORCH | 1725 E 86TH ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | 3RD FLOOR: DEAD PIGEON ON LANDING | 1725 E 86TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXERIOR WALLS EAST AND WEST (MINOR) WASHED OUT MORTAR. | 1725 E 86TH ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S ID SIGN POSTED. | 1725 E 86TH ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | WEST CHIMNEY MISSING CAP. | 1725 E 86TH ST | COMPLAINT | FAILED | View |
INSTALL EXTRA SMOKE DETECTORS | INTERIOR, 3RD FLOOR: SMOKE DETECTOR NOT SOUNDING | 1725 E 86TH ST | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE: DOOR PANELS ROTTED, AND/OR MISSING, PEELING PAINT, GUTTERS: OVERGROWN WEEDS AND RUSTED, SERVICE DOOR GAP AT TOP, ROTTED DOOR FRAME | 1725 E 86TH ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | SOUTH & WEST ELEVATIONS: WINDOW FRAMES ROTTED | 1725 E 86TH ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO VERIFY COMPLAINT OF BEDBUG INFESTATION AT 3RD FLOOR UNIT, | 1725 E 86TH ST | COMPLAINT | FAILED | View |