Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CHIMNEY | CHIMNEY - WASHED OUT MORTAR. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | RUSTED AND SAGGING LINTELS. LINTELS OVER 3 FEET IN LENGTH PLANS AND PERMIT REQUIRED. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | MISSING HANDRAIL. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 1. 6X6 COLUMNS RESTING ON CONCRETE BLOCKS SET IN DIRT OR ON CONCRETE SLAB.2. 4X4 COLUMNS RESTING IN DIRT - NO FOUNDATION.3. FOUNDATION STATUS UNKNOWN.4. 6X6 COLUMNS OVER NOTCHED.5. LOOKOUT BEAMS OVER SPANNED.6. STRINGERS INADEQUATELY SUPPORTED.7. LAP JOINTS ON COLUMNS WITH LARGE GAPS AND 2 BOLTS.8. PLANS ANS PERMIT REQUIRED FOR PORCH AND RAMP. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | MISSING GUARDRAIL. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOW FRAMES ROTTED AND SKABBED. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
INSUFFICIENT MEANS OF EGRESS | LANDING ON STAIRWAY HAS LESS THAN 36 INCHES OF CLEAR PATH OF TRAVEL. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR COPING | NORTH ELEVATION/ COPING STONEWORK- WASHED OUT MORTAR. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | NEW REAR EXTERIOR PORCH HAS BEEN BUILT UNDER PERMIT #100346495, ISSUED ON 06/17/2010. NO PLANS OR PERMIT AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION. SUBJECT TO FIELD INSPECTION, AND APPROVAL. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | WEST CHIMNEY CAPPING; MISSING. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | NORTH SERVICE WALK; BROKEN CONCRETE. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
PARAPET | SOUTH-EAST CORNER PARAPET WALL; BUCKLING OUT. WEST PARAPET WALL; MORTAR MISSING. NORTH PARAPET WALL; BRICK MISSING AND MORTAR MISSING. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | NORTH ELEVATION LINTELS; RUSTED AND SAGGING [SUBMIT PLANS AND PERMITS TO REPLACE LINTELS]. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY MORTAR MISSING. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH; FOOTINGS BROKEN CONCRETE,1ST TO 2ND FLR.STRINGER BROKEN,G TO 1ST FLR.HAND RAIL LOOSE,2X8 RIM JOIST,6X6 UPRIGHT WOOD SPLIT,LOOKOUT PULLING AWAY FROM SUPPORT,1ST TO 2ND FLR.STRINGER OVERCUT,RIM JOIST SCAB TOGETHER,G TO 1ST FLR.STRINGER NOT SITTING FLUSH ON SUPPORT.[SUBMIT PLANS AND PERMITS TO REPLACE PORCH SYSTEM]. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | 2ND FLR.KITCHEN DOOR FRAME; BROKEN. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLR.BATHROOM WALL HAS MOLD. BASEMENT INTERIOR WALL; BRICKS DETERIORATING. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FLUSH TANK | 1ST FLR.BATHROOM FLUSH TANK TOP; BROKEN. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST FLR.KITCHEN FLOOR TILES BROKEN,DINING ROOM AND BEDROOM WOOD FLOOR STRIPS BROKEN. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | BASEMENT CEILING; BROKEN AND BUCKLING PLASTER. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | BASEMENT FURNACE NOT ENCLOSE IN STORAGE ROOM. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | NORTH SERVICE WALK; BROKEN CONCRETE. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
PARAPET | SOUTH-EAST CORNER PARAPET WALL; BUCKLING OUT. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | NORTH ELEVATION 2ND FLR.LINTELS; SAGGING [PERMIT FOR REAPIRS]. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR COPING | NORTH ELEVATION COPING STONE; OPEN JOINTS. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY MORTAR MISSING. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 2ST.REAR PORCH; G TO 1ST FLR.HAND RAIL LOOSE,6X6 UPRIGHT OVERCUT AND TWISTED,LOOKOUTS PULLING AWAY FROM METAL BRACKETS,6X6 BLOCK TOE NAIL TO 6X6 UPRIGHTS FOR PORCH ROOF SUPPORTS.[SUBMIT PLANS AND PERMITS FOR REPAIRS] | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | NORTH ELEVATION/ LINTELS- RUSTING, WITH PEELING PAINT. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | WEST CHIMNEY CAPPING; MISSING. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR COPING | NORTH ELEVATION COPING STONES; OPEN JOINTS. | 4821 W PALMER ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST AND NORTH EXTERIOR WALLS; BRICKS BUCKLING OUT.[SUBMIT PERMITS TO RESET BRICKS] | 4821 W PALMER ST | COMPLAINT | FAILED | View |