Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
EXPOSED WIRING | FRONT INTERIOR STAIRS LIGHT FIXTURE AND 2ND FLOOR WALL SWITCH-EXPOSED WIRES. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD / JUNK AND REFUSE,USED LUMBER,CAR TIRES,TUB,LADDERS,USED FURNITURE. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRS AND 2ND FLOOR APARTMENT-MISSING SMOKE DETECTORS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | BUILDING / 2ND FLOOR APARTMENT CEILING THROUGH-OUT PEELING PAINT WITH WATER STAINS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT INTERIOR STAIRS / MISSING HAND RAIL.STRINGERS AND TREADS ROTTED WITH SECTIONS MISSING-HOLES THERE.PERMIT REQUIRED. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
RATS | FRONT AND REAR YARD-RATS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT AND SOUTH ELEVATION / EXTERIOR WALLS,1ST AND 2ND FLOORS-LOOSE AND HANGING SIDING. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER'S ID SIGN POSTED. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | SOUTH ELEVATION / ROOF MISSING GUTTER AND DOWNSPOUT IN FRONT,REAR GUTTER IS RUATED WITH MISSING DOWNSPOUT. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
PROVIDE COLD WATER TO FICTURES | 2ND FLOOR APARTMENT / WATER SHUT-OFF. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT 1 STORY WOOD PORCH.LEDGER BEAM,ONLY FACE NAILED TO BUILDING.UNDER SIZED 2X6 JOISTS SPAN 12 FEET,STRINGERS ONLY FACE NAILED AT TOP CONNECTION,NORTH STRINGER IS CRACKED,TREADS ARE LOOSE.RISER HEIGHT NOT UNIFORM HEIGHT VARYING FROM 5 INCHES TO 7 INCHES.DECKING IS BUCKLING.RAILING ONLY 31 INCHES IN HEIGHT,HAND RAILS ARE HORIZONTAL WITH 15 INCH SPACING.PLANS AND PERMIT REQUIRED FOR REPAIRS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR YARD / TWO ABANDONED AUTO'S AND ONE MOTORCYCLE.OVER GROWN TREES INTO ELECTRICAL LINES. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
PROV HOT WTR TO ALL FIXTURES | 2ND FLOOR APARTMENT / WATER SHUT-OFF. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
KEEP FIXTUR CLEAN AND SANITARY | 2ND FLOOR APARTMENT / TOILET FULL OF FECES. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | FRONT INTERIOR STAIR CEILING,LOOSE AND MISSING 4X4 FOOT SECTION OF PLASTER,WATER STAINS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | REAR EXTERIOR PORCH ROOF-ROTTED SHEETING,WITH HOLES.PERMIT REQUIRED FOR REPAIRS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
RAT STOP AROUND EXTERIOR | FRONT AND REAR YARD / RAT HARBORAGE. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 2ND FLOOR APARTMENT / GAS SHUT-OFF. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | FRONT EXTERIOR ENTRY DOOR AND FRAME TO 2ND FLOOR-BROKEN FRAME. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING / NO ENTRY,UNVERIFIED DETECTORS,OCCUPANCY,CONDITIONS,UNABLE TO VERIFY COMPLAINT OF UNIT-1,MOLD IN KITCHEN AND BATHROOM,BROKEN GLASS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING / NO ENTRY,UNVERIFIED DETECTORS,OCCUPANCY,CONDITIONS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | BASEMENT WINDOW HAS SILL MISSING. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | EAVES ARE ROTTED. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT, WOOD, ROOFED PORCH; ROOF IS ROTTED, PORCH HAS EXCESSIVE PITCH, ROUND PILLARS (COLUMNS) ARE SPLITTING. RAILS ARE BROKEN AND LOOSE ALSO MISSING PICKETS. OBTAIN PERMIT. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
GRADE AND DRAIN LOT | AT FRONT YARD THERE IS A LARGE HOLE BY THE BASEMENT WINDOW, REARYARD IS UNEVEN (SIGNS OF VEHICULAR TRAFFIC) WITH MUD AND PUDDLES OF WATER. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BASEMENT WINDOW IS BROKEN. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REARYARD HAS DEBRIS SCATTERED; PCV PIPE, WOOD, DOOR AND DRAIN PIPE. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ARRANGE FOR INSPECTION TO VERIFY SMOKE AND CARBONMONOXIDE DETECTORS BASEMENT TO ATTIC. ALSO TO VERIFY CONDITION OF INTERIOR AND PORCH SYSTEM. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | CONNECT CATCH BASIN TO SAME | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | SR#100091634 | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | BACKYARD | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | GATE CHAINED LOCKED. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | WEEDS OVER 2FT. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
MAINTAIN PROJECTIONS | ROTTED FACIA, AND TRIM. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | ROTTED, BROKEN, AND MISSING. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF SHINGLES, WARPED,LOOSE,BUCKLED, DRIED ROTTED. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | ROTTED EAVES. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | PLANS, AND PERMIT REQUIRED FOR REPLACEMENT. FRONT PORCH, ROTTED WOOD COLUMS, AND SPLIT, BRICK COLUMNS LEANING, ROTTED DECKING, ROTTED, AND WARPED TREADS, ROTTED, AND SPLIT STRINGERS, NO JOIST HANGERS, JOIST ROTTED, LEDGERS NOT BOLTED, GUARD RAILS ROTTED, WEAK, AND UNDER 42 INCHES. REAR 2 STORY PORCH, ENTIRE PORCH ROTTED, AND LEANING, AS FOLLOW, STAIR STRINGERS ROTTED, AND DISCONNECTED FROM HEADERS, PARTIALLY COLLAPSED, WITH A 2X4 SUPPORTING IT IN PLACE, JOIST ROTTED, AND OVER SPANNED, 2X8X12FT., COLUMNS BUTT JOINTS, ROTTED, AND TWISTING, FOOTINGS UNKNOWN, DECKING ROTTED, NO STEEL STRAPS,REPLACEMENT REQUIRED, PORCH IN HAZARDEOUS CONDITIONS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
GRADE AND DRAIN LOT | HOLES, FRONT, AND REAR YARD, WATER RUN OFF. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | RUSTED, AND MISSING SECTIONS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | FENCE RUSTED, LOOSE, BENT TOP RAIL. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOWS MISSING. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | ROTTED, AND MISSING SASHES. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | MISSING PUTTY. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
RAT STOP AROUND EXTERIOR | RAT HOLES. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | JUNK, AND DEDRIS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
RATS-ELEVATE MATERIAL 18" | EXCESSIVE STORAGE IN BASEMENT, IN PILES. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | ABANDON CARS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR TO VERIFY DETECTORS, AND OCCUPANCY. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | BASEMENT, SEWER ODORS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | STAGNANT WATER. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOW FRAMES ROTTED, AND WITH FLAKING PAINT. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION/FRONT EXTERIOR STAIRWAY - FROM GROUND TO FIRST FLOOR - MISSING PICKETS. HANDRAILS MADE OF 2X4 WOOD BOARDS AND SOUTH HANDRAIL IS LOOSE. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WEST ELEVATION/ATTIC WINDOWS - ROTTED WOOD FRAMES WITH PEELING PAINT. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION/EXTERIOR WALL - MISSING SIDING AND EXPOSED PLYWOOD NEXT TO FRONT ENTRANCE DOOR. SOUTH ELEVATION - MISSING SIDING NEAR WEST END. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | WEST ELEVATION/ROOF EAVES - ROTTED AND BROKEN WOOD WITH PEELING PAINT. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | ALL ELEVATIONS/GUTTERS AND DOWN SPOUTS - RUSTED METAL. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNABLE TO VERIFY DETECTORS, CONDITIONS, OCCUPANCY AND COMPLAINT OF NO SMOKE DETECTORS, NO CARBON MONOXIDE DETECTORS AND NO FIRE EXTINGUISHERS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
MAINTAIN PROJECTIONS | FRONT ENTRANCE CANOPY/ROOF/PLYWOOD AND FASCIA BOARD - ROTTING AND PULLING APART. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING / NO ENTRY,UNVERIFIED DETECTORS,CONDITIONS,UNABLE TO VERIFY COMPLAINT OF 1ST FLOOR APARTMENT-CEILING CAVING IN,MOLD. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT ELEVATION / EXTERIOR SIDING-MISSING SECTIONS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD / JUNK AND REFUSE ACCUMULATING. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF THE BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. NO ENTRY - UNABLE TO VERIFY COMPLAINT OF MISSING SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS IN THE ENTIRE BUILDING. REAR YARD - LOCKED GATES, NO ENTRY TO INSPECT REAR PORCH. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | FRONT ELEVATION / GRADE TO FIRST FLOOR / 1-STORY FOOD PORCH - ALL COLUMNS ERECTED ON SOIL, FOUNDATION STATUS UNKNOWN. UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS WITH NAILS ONLY; OVERCUT, WEAK. DECK BOARDS - ROTTING, CRACKED AND BUCKLED UP. ALL RAILING SECTIONS - LOOSE, WEAK, PULLING; MISSING PICKETS. ENTIRE PORCH STRUCTURE - WEAK. PLANS AND PERMIT REQUIRED FOR REPLACEMENT OF FRONT PORCH. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR ROOF STRUCTURE | EAST ELEVATION / ROOF - ROOF HAS LARGE HOLE, ROTTING ROOF SHEATING AND ROOF RAFTERS. PLANS AND PERMIT REQUIRED FOR ROOF REPAIRS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | EAST ELEVATION / 3-STORY WOOD PORCH / ALL LANDING - ACCUMULATION OF OLD PLUMBING FIXTURES, CABINETS, BUILDING MATERIALS, ETC., OBSTRUCTING PATH OF EGRESS. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH AND WEST ELEVATIONS / GRADE TO TOP OF THE BUILDING / LARGE SECTIONS OF SIDING - FALLING DOWN, MISSING, EXPOSED BUILDING'S SHEATING. PERMIT ONLY REQUIRED FOR SIDING REPLACEMENT. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | SOUTH-WEST CORNER / SECTIONS OF DOWNSPOUT - MISSING. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | BASEMENT DANGEROUS AND HAZARDOUS | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | BASEMENT AND REAR PORCH DANGEROUS AND HAZARDOUS | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | BASEMENT AND REAR PORCH, CORDS ON FLOORS, STANDING WATER, DANGEROUS AND HAZARDOUS | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | LOCATED REAR EXTERIOR | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR UNIT - MISSING SMOKE DETECTORS.2ND FLOOR FRONT INTERIOR STAIRWELL - MISSING SMOKE DETECTOR. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR UNIT - MISSING CARBON MONOXIDE DETECTOR. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | 1ST FLOOR UNIT - BATHROOM LIGHT AND FAN FIXTURES HANGING FROM CEILING WITH EXPOSED WIRES. 2ND FLOOR FRONT INTERIOR STAIRS. LIGHT BROKEN. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | BASEMENT - MAIN ELECTRICAL PANELS OPEN WITH EXPOSED WIRES GOING IN ALL DIRECTIONS. 1ST FLOOR UNIT - UNIT ELECTRICAL PANEL OPEN WITH EXPOSED WIRES.2ND FLOOR UNIT - UNIT ELECTRICAL PANEL OPEN WITH EXPOSED WIRES. OPEN ELECTRICAL LINE BEING INSTALLED THROUGH EXTERIOR KITCHEN WALL.2ND FLOOR UNIT - MULTIPLE OUTLETS AND LIGHT SWITCHES MISSING COVER PLATES AND RECEPTACLES PULLED FROM WALL EXPOSING ALL WIRES. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | EAST ELEVATION, EXTERIOR OPEN WOOD PORCH SYSTEM. PORCH HAS LARGE AMOUNTS OF CONSTRUCTION MATERIALS AND JUNK BEING STORED ON DECK. EGRESS OBSTRUCTED. EAST ELEVATION, 2ND FLOOR UNIT - REAR DOOR MISSING DOOR KNOB ON INSIDE OF UNIT. TENANTS NOT ABLE TO OPEN DOOR IN AN EMERGENCY - DANGEROUS AND HAZARDOUS | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | ALL FLOORS, ONGOING ELECTRICAL WORK BEING DONE WITHOUT PERMITS. OPEN PANELS AND RECEPTICALS. MULTIPLE CONDUIT LINES BEING INSTALLED ON WALLS. DANGEROUS AND HAZARDOUS WITH EXPOSED WIRES AT ALL LEVELS - CHILDREN IN 2ND FLOOR UNIT. 1ST AND 2ND FLOORS - PLUMBING PIPES BEING INSTALLED ON WALLS IN THE KITCHEN AND BATHROOM WITHOUT PERMITS. SOME PIPING EXPOSED AND GOING INTO THE ATTIC. RETURN TO ORIGINAL STATE OR OBTAIN PERMITS. ALL WORK SUBJECT TO REVIEW AND APPROVAL BY ALL RELATED TRADES. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | 2ND FLOOR DINNING ROOM - WATER LEAKING FROM CEILING AND ENTRY INTO LIVING ROOM. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | EAST ELEVATION, 2ND FLOOR UNIT - REAR DOOR MISSING DOOR KNOB ON INSIDE OF UNIT. TENANTS NOT ABLE TO OPEN DOOR IN AN EMERGENCY - DANGEROUS AND HAZARDOUS | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | NORTH FRONT INTERIOR STAIR SYSTEM. - MULTIPLE STAIR TREADS WEAK AND ROTTEN. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH ELEVATION, FRONT INTERIOR STAIRWELL - WINDOW AT TOP OF STAIR BROKEN AND MISSING. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | FRONT AND SOUTH ELEVATIONS-MISSING SIDING. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING-NO RESPONSE,UNVERIFIED DETECTORS,AND CONDITIONS ' | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | FRONT ELEVATION -GABLE ROOF;TREE AND STORM DAMAGED,TORN ROOFING SHINGLES. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT ENTRANCE DOOR TO SECOND FLOOR-MISSING LOCK SET AND DEAD BOLT.FRONT ENTRANCE DOOR TO FIRST FLOOR-MISSING DEAD BOLT. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | GUTTER AT FRONT PORCH IS SHORT, DOES NOT COVER THE SPAN OF THE ROOF. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
CLEAN CATCH BASIN | BACKYARD | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | CALL (312) 743-0413 | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION/BASEMENT WINDOW - BOARDED UP, MISSING WINDOW PANE. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
CONNCT PLUMBING SYSTEM TO SEWR | PUMPING TO PUBLIC SIDEWALK - HOSES FROM BASEMENT WINDOW, CREATING UNSANITARY CONDITION. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR CATCH BASIN | CLEAN CATCH BASIN BACK YARD | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | PLYWOOD, FURNITURE, 2X4. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | BASEMENT AND REAR PORCH DANGEROUS AND HAZARDOUS | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
SECURE RACEWAY | BASEMENT | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 2ND FLOOR FRONT INTERIOR STAIRWELL - CEILING SEVERELY WATER DAMAGED WITH MISSING DRYWALL/PLASTER AND EXPOSED ROTTING JOISTS. 1ST FLOOR UNIT DINING ROOM - HOLE IN WALL - OPENING IN WALL AT EXHAUST SHAFT ACCESS COVER REMOVED. 1ST FLOOR UNIT - FRONT BEDROOM WATER STAINED CEILING. BATHROOM WALLS AND CEILING SEVERELY WATER DAMAGED WITH EXTENSIVE AMOUNTS OF MILDEW. BOTTOM TUB ENCLOSURE MISSING. KITCHEN CEILING WATER DAMAGED. 2ND FLOOR DINNING ROOM AND LIVING ROOM - CEILING AND WALLS WATER DAMAGED. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | EAST ELEVATION - 4FT SECTION OF WOOD FENCE BUILT WITHOUT A PERMIT.PERMIT NOW REQUIRED SUBJECT TO FIELD INSPECTION AND APPROVAL. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | FRONT STAIRWELL AND 2ND FLOOR DINING ROOM (NORTH WALL) (DANGEROUS AND HAZARDOUS) | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | 2ND FLOOR KITCHEN COUNTERTOPS, NO POWER, REAR OF APARTMENT BEDROOMS LIGHTS AND RECEPTACLES NOT WORKING | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
SMOKE & CARBON DETECTORS | 2ND FLOOR | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
UNAPPROVED CORDS | 2ND FLOOR KITCHEN. EXTENSION CORD CONNECTED TO LIGHT FIXTURE FROM PORCH FROM 2ND FLOOR APARTMENT (DANGEROUS AND HAZARDOUS) | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | 2ND FLOOR FURNACE ROOM MISSING COVER ON RECEPTACLE | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING FIXTURES | 2ND FLOOR FURNACE ROOM ABOVE DOOR | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
CONNCT PLUMBING SYSTEM TO SEWR | PUMPING TO PUBLIC SIDEWALK - CREATING UNSANITARY CONDITION. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | STOP ODORS - STANDING SEWAGE ON PUBLIC SIDEWALK. | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | CALL (312) 743-0413 OR WWW.CITYOFCHICAGO.ORG | 2053 N SAWYER AVE | COMPLAINT | FAILED | View |