The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | 2 STORY REAR PORCH: WEST ELEVATION HAS A COLLAPSED ROOF, IMPROPER CONNECTIONS TO GUARD RAILS, BEAMS, HANDRAILS, AND JOIST, UNDERSIZED JOIST AND HANDRAILS, 2ND FLOOR-BROKEN BOTTOM GUARDRAIL | 4502 S WELLS ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS & PERMITS BEFORE STARTING WORK; NORTH & SOUTH ELEVATIONS: EAVES AND SOFFITS HAVE ROTTED WOOD; NORTH AND SOUTH ELEVATIONS: GUTTERS AND DOWNSPOUTS MISSING; WEST ELEVATION: MINERAL SIDING MISSING; SOUTH ELEVATION, 2ND FLOOR: WINDOW PANE MISSING, ALSO, ATTIC WINDOW, EAST ELEVATION, BROKE PANES; MISSING AND DRY ROTTED ROLLED ROOFING ON ROOF AND CANOPY; POST OWNER OR MANAGEMENT SIGN ON FRONT OF BUILDING WITH PHONE NUMBER; ARRANGE FOR INTERIOR INSPECTION | 4502 S WELLS ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT STAIR SYSTEM WITH WEAK HAND RAILING, SOUTH SECTION WITH A DISCONNECTED GROUND POST.2.-GUARD RAILING ARE TOO LOW AND WEAK ANCHOR AREAS.3.-UNKNOWN FOOTING UNDER POSTS/COLUMNS.4.-RIBBON JOISTS TOE NAILED TO COLUMNS AND INSIDE JOIST WITH OUT HANGERS. | 4502 S WELLS ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALLS WITH SEVERELY DETERIORATED ASPHALT SIDING, OPEN JOINTS AND MULTIPLE AREAS HAVE IT MISSING AND SHOW EXPOSED WOOD SHEATHING ROTTING UNDER THE SIDING. | 4502 S WELLS ST | COMPLAINT | FAILED | View |
REPAIR EAVES | MULTIPLE AREAS OF ROOF EAVES HAVE THE FACIA BOARD ROTTED AND/OR WITH CRITTER DAMAGE | 4502 S WELLS ST | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF ROLLED ASPHALT FINISH IS MISSING AT MULTIPLE LOCATIONS EXPOSING THE WOOD SHEATHING TO THE ELEMENTS. | 4502 S WELLS ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH SYSTEM WITH UNKNOWN FOOTING UNDER COLUMNS.2.-COLUMNS HAVE BEEN ASSEMBLED WITH OUT THE PROPER LAP JOINT AND BOLT.3.-EXTERIOR JOISTS(RIBBON JOISTS) HAVE BEEN TOE NAILED TO COLUMNS. INTERIOR JOISTS WITH OUT THE PROPER METAL HANGERS WHERE REQUIRED.4.-DECK AND LANDING BOARDS ROTTING AND THE FIRST FLOOR WITH CHARCOAL BURNT AREA.5.-GUARD AND HAND RAILS WITH MULTIPLE PICKETS MISSING AND ALL ANCHOR ON THE OUTSIDE OF RAIL, WEAK ANCHOR AREAS. GUARD RAIL HEIGHT IS TOO LOW.6.-ROOF STRUCTURE HAS FOR THE MOST PART COLLAPSED, ALL THAT REMAINS ARE THE NORTH AND SOUTH ENDS.7.-STRINGERS ARE TOE NAILED TO EXTERIOR WALL AND TOP AND BOTTOM ENDS.8.-SUBMIT PLAN AND OBTAIN PERMIT TO RESTORE AND BRING SYSTEM TO CODE. | 4502 S WELLS ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | BASEMENT DOOR IS OFF HINGES AND IN-BEDDED IN ICE LEAVING THE BASEMENT AREA WITH EASY ACCESS AND OPEN TO THE ELEMENTS. | 4502 S WELLS ST | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | FRONT AND REAR ATTIC AS WELL AS THE FRONT OF THE BASEMENT WINDOW FRAME ARE INCOMPLETE-SEE PLYWOOD ATTEMPTING TO COVER THE OPENINGS. | 4502 S WELLS ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | WATER SERVICE HAS BEEN SHUT OFF DUE TO LARGE LEAKS EMANATING FROM THE BASEMENT AND SPILLING OVER TO THE PROPERTY NORTH OF BUILDING. BASEMENT IS UNDER THREE OR FOUR FEET OF ICE. | 4502 S WELLS ST | COMPLAINT | FAILED | View |
PROVIDE COLD WATER TO FICTURES | WATER HAS BEEN SHUT OFF. | 4502 S WELLS ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | NORTHWEST CORNER OF FOUNDATION BLOCK WALL WITH AN AREA OF EXTENSIVE MOLD BUILD UP, SEE GREEN AND BLACK SUBSTANCE GROWING. | 4502 S WELLS ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REMOVE ALL JUNK AND AND HOUSE HOLD DEBRIS ON THE EXTERIOR OF YARD AND PORCH SYSTEM. | 4502 S WELLS ST | COMPLAINT | FAILED | View |
REPAIR FENCE | MULTIPLE SECTIONS OF CHAIN LINK FENCE WITH BENT TOP RAILS AND POSTS, DISCONNECTED WIRE MESH SECTIONS. | 4502 S WELLS ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | MULTIPLE WINDOWS HAVE EITHER THE PANE MISSING AND/OR CRACKED. | 4502 S WELLS ST | COMPLAINT | FAILED | View |