Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:07 PM
PIN: 20162170140000
Property Address: 5833 S PRINCETON AVE
City - Zip: CHICAGO - 60621
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72092
2023 Tax District: 72001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 22 Violations
Violation Inspector Comments Address Category Status View
DEFECTIVE DISTRIBUTION (18-27-338.3) SERVICE ENTRANCE-CABLE NOT PERMITTED FOR FEEDERS- BASEMENT DISCONNECT TO 2ND FLOOR PANEL 5833 S PRINCETON AVE COMPLAINT FAILED View
DEFECTIVE BREAKER (18-27-240.80) 1ST FLOOR APARTMENT CIRCUIT BREAKER (MAIN) 100 AMP DEFECTIVE. 3-20 AMP/4-15 AMP BREAKERS DO NOT OPEN. -DANGEROUS & HAZARDOUS 5833 S PRINCETON AVE COMPLAINT FAILED View
COVER OUTLETS AND JBS (18-27-370.25) BASEMENT COVERS MISSING 5833 S PRINCETON AVE COMPLAINT FAILED View
CIRCUIT ONE UNIT ONLY (18-27-560.23) SEPARATE 1ST FLOOR APARTMENT FROM BASEMENT CIRCUITS. 5833 S PRINCETON AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION 2ND. FL. APT. - ENTRY REFUSED;UNABLE TO VERIFY DETECTORS, CONDITIONS, AND OCCUPANCY; 5833 S PRINCETON AVE COMPLAINT PASSED View
REPAIR GUTTER SOUTH ELEVATION /ROOF GUTTERS - LOOSE, HANGING; 5833 S PRINCETON AVE COMPLAINT PASSED View
PROVIDE GUARD RAIL 42 IN HIGH FRONT ELEVATION /EXTERIOR METAL GUARD RAILING SECTION ONLY 32 INCHES HIGH - LOOSE AND PULLING; STAIR RAILING SECTION ONLY 30 INCHES HIGH - LOOSE AND PULLING; RUSTING; 5833 S PRINCETON AVE COMPLAINT PASSED View
REPAIR SCREENS FRONT ELEVATION /WINDOW SCREENS - RIPPED AND MISSING; 5833 S PRINCETON AVE COMPLAINT PASSED View
INSTALL SMOKE DETECTORS FRONT STAIRWAY, BASEMENT AND 1ST. FL. APT. - SMOKE DETECTOR - MISSING; 5833 S PRINCETON AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID BASEMENT AND 1ST. FL. APT. /CARBON MONOXIDE DETECTOR - MISSING; 5833 S PRINCETON AVE COMPLAINT PASSED View
MICE/RODENTS BUILDING THROUGHOUT ¿ MICE; RODENT DROPPINGS OBSERVED IN 1ST. FL. APT.; 5833 S PRINCETON AVE COMPLAINT PASSED View
ROACHES BUILDING THROUGHOUT ¿ ROACHES; AS OBSERVED OBSERVED IN 1ST. FL. APT.; 5833 S PRINCETON AVE COMPLAINT PASSED View
INT WALL/CEILING CHIP PLASTER 1ST. FL. APT. /BATHROOM WALLS AND CEILING - MILDEW; 5833 S PRINCETON AVE COMPLAINT PASSED View
DEBRIS, EXCESSIVE BASEMENT - JUNK DEBRIS; 5833 S PRINCETON AVE COMPLAINT PASSED View
DEFECTIVE FIXTURES 1ST. FL. APT. /KITCHEN, LIVING ROOM AND BEDROOM FIXTURES - OUT OF SERVICE; 5833 S PRINCETON AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR 2 STORY WOOD PORCH;FOUNDATION /COLUMNS ERECTED ON TOP OF CONCRETE SLAB; FOUNDATION STATUS UNKNOWN;STRINGERS /UPPER ENDS OF STRINGERS INADEQUATE SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; LOWER ENDS OF STRINGERS INADEQUATE SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY;STAIRS /; LANDING BETWEEN 1ST. AND 2ND. ¿ UNSTABLE; PULLING; SWAYING;RAILINGS /STAIR RAILING SECTIONS ¿ LOOSE AND PULLING [GRADE TO 1ST.];SOUTH ELEVATION /1 STORY WOOD PORCH;FOUNDATION /COLUMNS ERECTED ON 10 X 10 INCH CONCRETE BLOCK AND ERECTED ON TOP OF CONCRETE SLAB; NO BASE PLATES; FOUNDATION STATUS UNKNOWN;RAILINGS /STAIR RAILING SECTIONS ¿ LOOSE AND PULLING; DEFLECTING UNDER LOAD; ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALLS WITH NAILS /SCREWS ONLY;PLANS AND PERMIT REQUIRED TO REPLACE /REPAIR: REAR 2 STORY WOOD PORCH AND SOUTH ELEVATION /1 STORY WOOD PORCH; 5833 S PRINCETON AVE COMPLAINT PASSED View
REPAIR/REBUILD GARAGE OR SHED GARAGE /ROOF - SAGGING INWARD;PERMIT REQUIRED TO REPLACE /REPAIR GARAGE ROOF; 5833 S PRINCETON AVE COMPLAINT PASSED View
SEE INSPECTOR COMMENTS (18-27-210.25) INSTALL METER & PANEL FOR BASEMENT AND COMMON/AREA CIRCUITS 5833 S PRINCETON AVE COMPLAINT FAILED View
RESET LOOSE FIXTURE 1ST. FL. APT. /BATHROOM TOILET - LOOSE; 5833 S PRINCETON AVE COMPLAINT PASSED View
STOP LEAKING WATER 1ST. FL. APT. /BATHROOM SINK - LEAKING; 5833 S PRINCETON AVE COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIR SYSTEM - TREADS - LOOSE; STAIR RAILING SECTION [GRADE TO 2ND. FL.] - LOOSE; GRADE TO BASEMENT /STAIRS - RISERS NOT UNIFORMED, RANGING FROM 7 ½ INCHES TO 10 1/2 INCHES; 5833 S PRINCETON AVE COMPLAINT PASSED View
STOP/REMOVE NUISANCE BASEMENT /OBNOXIOUS ODOR; 5833 S PRINCETON AVE COMPLAINT PASSED View