DEFECTIVE DISTRIBUTION | (18-27-338.3) SERVICE ENTRANCE-CABLE NOT PERMITTED FOR FEEDERS- BASEMENT DISCONNECT TO 2ND FLOOR PANEL | 5833 S PRINCETON AVE | COMPLAINT | FAILED | View |
DEFECTIVE BREAKER | (18-27-240.80) 1ST FLOOR APARTMENT CIRCUIT BREAKER (MAIN) 100 AMP DEFECTIVE. 3-20 AMP/4-15 AMP BREAKERS DO NOT OPEN. -DANGEROUS & HAZARDOUS | 5833 S PRINCETON AVE | COMPLAINT | FAILED | View |
COVER OUTLETS AND JBS | (18-27-370.25) BASEMENT COVERS MISSING | 5833 S PRINCETON AVE | COMPLAINT | FAILED | View |
CIRCUIT ONE UNIT ONLY | (18-27-560.23) SEPARATE 1ST FLOOR APARTMENT FROM BASEMENT CIRCUITS. | 5833 S PRINCETON AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | 2ND. FL. APT. - ENTRY REFUSED;UNABLE TO VERIFY DETECTORS, CONDITIONS, AND OCCUPANCY; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
REPAIR GUTTER | SOUTH ELEVATION /ROOF GUTTERS - LOOSE, HANGING; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | FRONT ELEVATION /EXTERIOR METAL GUARD RAILING SECTION ONLY 32 INCHES HIGH - LOOSE AND PULLING; STAIR RAILING SECTION ONLY 30 INCHES HIGH - LOOSE AND PULLING; RUSTING; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
REPAIR SCREENS | FRONT ELEVATION /WINDOW SCREENS - RIPPED AND MISSING; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | FRONT STAIRWAY, BASEMENT AND 1ST. FL. APT. - SMOKE DETECTOR - MISSING; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | BASEMENT AND 1ST. FL. APT. /CARBON MONOXIDE DETECTOR - MISSING; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
MICE/RODENTS | BUILDING THROUGHOUT ¿ MICE; RODENT DROPPINGS OBSERVED IN 1ST. FL. APT.; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
ROACHES | BUILDING THROUGHOUT ¿ ROACHES; AS OBSERVED OBSERVED IN 1ST. FL. APT.; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
INT WALL/CEILING CHIP PLASTER | 1ST. FL. APT. /BATHROOM WALLS AND CEILING - MILDEW; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | BASEMENT - JUNK DEBRIS; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | 1ST. FL. APT. /KITCHEN, LIVING ROOM AND BEDROOM FIXTURES - OUT OF SERVICE; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY WOOD PORCH;FOUNDATION /COLUMNS ERECTED ON TOP OF CONCRETE SLAB; FOUNDATION STATUS UNKNOWN;STRINGERS /UPPER ENDS OF STRINGERS INADEQUATE SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; LOWER ENDS OF STRINGERS INADEQUATE SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY;STAIRS /; LANDING BETWEEN 1ST. AND 2ND. ¿ UNSTABLE; PULLING; SWAYING;RAILINGS /STAIR RAILING SECTIONS ¿ LOOSE AND PULLING [GRADE TO 1ST.];SOUTH ELEVATION /1 STORY WOOD PORCH;FOUNDATION /COLUMNS ERECTED ON 10 X 10 INCH CONCRETE BLOCK AND ERECTED ON TOP OF CONCRETE SLAB; NO BASE PLATES; FOUNDATION STATUS UNKNOWN;RAILINGS /STAIR RAILING SECTIONS ¿ LOOSE AND PULLING; DEFLECTING UNDER LOAD; ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALLS WITH NAILS /SCREWS ONLY;PLANS AND PERMIT REQUIRED TO REPLACE /REPAIR: REAR 2 STORY WOOD PORCH AND SOUTH ELEVATION /1 STORY WOOD PORCH; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE /ROOF - SAGGING INWARD;PERMIT REQUIRED TO REPLACE /REPAIR GARAGE ROOF; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | (18-27-210.25) INSTALL METER & PANEL FOR BASEMENT AND COMMON/AREA CIRCUITS | 5833 S PRINCETON AVE | COMPLAINT | FAILED | View |
RESET LOOSE FIXTURE | 1ST. FL. APT. /BATHROOM TOILET - LOOSE; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
STOP LEAKING WATER | 1ST. FL. APT. /BATHROOM SINK - LEAKING; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIR SYSTEM - TREADS - LOOSE; STAIR RAILING SECTION [GRADE TO 2ND. FL.] - LOOSE; GRADE TO BASEMENT /STAIRS - RISERS NOT UNIFORMED, RANGING FROM 7 ½ INCHES TO 10 1/2 INCHES; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | BASEMENT /OBNOXIOUS ODOR; | 5833 S PRINCETON AVE | COMPLAINT | PASSED | View |