Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR FENCE | FRONT ELEVATION /METAL GATE - OFF HINGES. | 7835 S CREGIER AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR ELEVATION /3 STORY DANGEROUS & HAZARDOUS WOOD PORCH WITH ROOF. -FOUNDATIONS /COLUMNS ERECTED ON TOP OF CONCRETE BLOCK, WITH NO BASES; FOUNDATION STATUS UNKNOWN. -COLUMNS /TWISTED, OVER NOTCHED.-BEAMS /ROTTING, SAGGING AT FIRE CUT, PULLING OUT OF FIRE CUTS. -ROOF BEAMS /STACKED ON TOP OF COLUMNS, FASTENED WITH NAILS/SCREWS ONLY. -DECK JOISTS /SINGLE HEADER JOISTS [AT TOP AND BOTTOM OF STAIR SYSTEM CONNECTIONS] - INADEQUATELY SUPPORTED AT SINGLE RIM JOISTS - LOOSE AND PULLING. DANGEROUS & HAZARDOUS CONDITIONS.-STRINGERS /UPPER AND LOWER ENDS OF STRINGERS, FASTENED WITH NAILS /SCREWS ONLY, CRACKED, BROKEN, SCABBED. -STAIRS /TREADS AND RISERS - WORN OUT, CRACKED, BROKEN, ROTTED, WEAK.-DECKING /DECK BOARDS, BUCKLED, ROTTED, LOOSE.-RAILINGS /ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY.PLANS AND PERMIT REQUIRED. | 7835 S CREGIER AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING /OWNER¿S I.D. SIGN ¿ MISSING. | 7835 S CREGIER AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | 7835 S. /NO POSTED ADDRESS. | 7835 S CREGIER AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | SOUTH ELEVATION /METAL DOOR LINTEL - BENT, RUSTED, DEFLECTING, WITH GAPS ABOVE IT.PERMIT REQUIRED. | 7835 S CREGIER AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | APT 1 WORKING CONDITIONS- BOILER BROKEN . PER SECTION CODE . (14X-3-305.1, 14X-8-804.1, 14X-8-804.4 AND 14X-8-804.5) BHA CODES | 7835 S CREGIER AVE | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 1ST APT / AIR SEEPAGE - IN KITCHEN DOOR AND WINDOWS.PER SECTION CODE (14X-3-303.13 AND 14X-12-1202.4.3.3 | 7835 S CREGIER AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | APT 1 TEMP AT 1131 PM LIV RM 62 AND KITCHEN 63 DEGREES. PER SECTION CODE 14X-8-802.2, 14X-8-802.2.1AND 14X-8-802.2.2) BHA CODES | 7835 S CREGIER AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 1ST FL APT / UNAPPROVE HEATING DEVICE - ELECT SPACE HEATER USED AS HEAT .PER SECTION CODE . (14X-7-705.4 BHA CODES | 7835 S CREGIER AVE | COMPLAINT | FAILED | View |
RELOCATE SMOKE DETECTOR | FRONT INTERIOR STAIR / SMOKE DETECTOR - 2FT TO THE CEILING. PER SECTION CODE (14B-9-907.2.10.1 THRU 14B-9-907.2.10.4) DETECTORS | 7835 S CREGIER AVE | COMPLAINT | FAILED | View |