Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 3:59 PM
PIN: 21303290320000
Property Address: 7831 S COLFAX AVE
City - Zip: CHICAGO - 60649
2023 Property Class: 315
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70080
2023 Tax District: 70131
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 54 Violations
Violation Inspector Comments Address Category Status View
NO PERMIT WIRING BUILDING COMPLETED REMODEL,COMPLETED REWIRE ALL NEW PANELS,NEW RISER FROM STORM DAMAFE ALSO 7831 S COLFAX AVE COMPLAINT FAILED View
SYSTEM III 7831 S COLFAX AVE COMPLAINT FAILED View
TENANT ACCESS TO SERVICE 7831 S COLFAX AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES EXTERIOR COVERS REQUIRED 7831 S COLFAX AVE COMPLAINT FAILED View
CLOSE BOX OPENINGS METER SOCKET ASSEMBLY MISSING MULTIPLE COVERS 7831 S COLFAX AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS WEST, 1ST FLOOR - SHATTERED PANE 7831 S COLFAX AVE COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR ALL UNITS - REAR SECURITY DOOR IS DOUBLE KEY LOCKED 7831 S COLFAX AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM THE 731 PORCH - NO JOIST HANGERS AT STAIR LANDINGS. PORCH AND STAIR BANISTERS ARE TOO LOW. COLUMN FOOTINGS DO NOT EXTEND BELOW GRADE - SET ON PATIO SLAB. NO BOLTS AT UPPER STAIR CASE CONNECTIONS. 7831 S COLFAX AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE REAR GARBAGE DUMPSTER OVERFLOWING WITH GARBAGE. EXTREMELY UNSANITARY - ATTRACTING RATS. 7831 S COLFAX AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR NO PLANS, PERMITS ON FILE FOR NEW REAR PORCH. 7831 S COLFAX AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO MANAGEMENT SIGN POSTED 7831 S COLFAX AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR NO PLANS OR PERMITS ON FILE FOR EXTENSIVE 8 UNIT APARTMENT RENOVATION - NEW PLUMBING/ELECTRICAL FIXTURES, WIRING AND PIPING THROUGHOUT. 7831 S COLFAX AVE COMPLAINT FAILED View
CARPETING FRONT STAIRWELL CARPETING IS FILTHY, SODDEN. 7831 S COLFAX AVE COMPLAINT FAILED View
RESET LOOSE FIXTURE 7831 2ND FLOOR WATER CLOSET LOOSE. 7831 S COLFAX AVE COMPLAINT FAILED View
INSTALL TRAP,WASTE,VENT PIPES PROPERLY TRAP AND VENT KITCHEN SINK 7831 2ND FLOOR ALL FIXTURES. BACKPITCHED AND NON-VENTED FIXTURES BASEMENT - 3RD FLOORS. 7831 S COLFAX AVE COMPLAINT FAILED View
RMV PLBFIX INSTALLD W/0 PERMIT REMOVE ALL PLUMBING ILLEGALLY AND IMPROPERLY INSTALLED WITHOUT PERMIT. 7831 S COLFAX AVE COMPLAINT FAILED View
EXPOSE FOR INSPECT APPROVAL REMOVE DRYWALL AT PLUMBING WALLS TO EXPOSE THE PIPING FOR INSPECTION. 7831 S COLFAX AVE COMPLAINT FAILED View
OPEN PROVIDE DRIP PANS UNDER WATER HEATERS 1ST FLOOR TO 3RD FLOOR (18-29-504.8) AS PER CODE. 7831 S COLFAX AVE COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC A LICENSED AND BONDED PLUMBING CONTRACTOR IS REQUIRED. 7831 S COLFAX AVE COMPLAINT FAILED View
SUBMIT PLANS FOR PLUMBING PRMT PROVIDE PLANS AND PERMITS FOR 8 UNIT BUILDING, 4 FIXTURES AND 1 WATER HEATER PER UNIT. 7831 S COLFAX AVE COMPLAINT FAILED View
SYSTEM III SYSTEM III 7831 S COLFAX AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES 7833 LIGHT HANGING LIVING ROOM BASEMENT UNIT 7831 S COLFAX AVE COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT COVER ON METER BOX BASEMENT 7831 S COLFAX AVE COMPLAINT FAILED View
VACANT BUILDING - REGISTER 7831 S COLFAX AVE COMPLAINT CLOSED View
ARRANGE PREMISE INSPECTION UNABLE TO GAIN ENTRY TO INTERIOR TO VERIFY DETECTORS AND OCCUPANCY. 7831 S COLFAX AVE PERIODIC FAILED View
REPAIR LINTELS WEST 3RD FLOOR WINDOW LINTELS - PACKED WITH MORTAR - LOOSE ALUMINUM CAPPING. MASONRY PERMIT REQUIRED TO REPLACE LINTELS IF ARE SAGGING. (SOUTH END) 7831 S COLFAX AVE COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS BUILDING,UNITS-1N,2N,2S,SMOKE DETECTORS,LOW BATTERY. 7831 S COLFAX AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BUILDING,UNIT-1N,2N.MISSING CARBON MONOXIDE DETECTORS. 7831 S COLFAX AVE COMPLAINT FAILED View
REPAIR DOOR FRAME, MULLION APARTMENT 3-S, APARTMENT AND KITCHEN DOOR FRAMES; BROKENAPARTMENT 2-S, APARTMENT DOOR FRAME; BROKEN. 7831 S COLFAX AVE PERIODIC FAILED View
SUPPORT FIXTURES APARTMENT 1-S, BATHROOM LIGHT FIXTURE; HANGING. 7831 S COLFAX AVE PERIODIC FAILED View
SAFE WORKING CONDITIONS APARTMENT 2-S, KITCHEN HEATING VENT; LOOSE AND HOT WATER TANK ROOM PLASTIC IN CEILING ATTACH TO FLUE PIPE. 7831 S COLFAX AVE PERIODIC FAILED View
ARRANGE COMPLETED PERMIT INSP. 7831 S COLFAX AVE PERMIT FAILED View
ARRANGE COMPLETED PERMIT INSP. 7831 S COLFAX AVE PERMIT FAILED View
ARRANGE COMPLETED PERMIT INSP. 7831 S COLFAX AVE PERMIT FAILED View
REPAIR EXTERIOR DOOR WEST EXTERIOR DOOR; BROKEN. 7831 S COLFAX AVE PERIODIC FAILED View
REPAIR EXTERIOR DOOR FRAME WEST EXTERIOR DOOR FRAME; BROKEN. 7831 S COLFAX AVE PERIODIC FAILED View
FILE BLDG REGISTRATION REGISTER BUILDING FOR 2014 AND 2015. 7831 S COLFAX AVE PERIODIC FAILED View
DEBRIS, EXCESSIVE PORCH AREA; JUNK AND DEBRIS. 7831 S COLFAX AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL ENCLOSE PORCH EXTEIOR WALLS; SIDING BROKEN AND MISSING. 7831 S COLFAX AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM SOUTH PORCH; FOOTING MISSING,LOOKOUTS ROTTED AND PULLING AWAY FROM SUPPORTS,GUARD RAILS PULLING AWAY FROM SUPPORTS,TREADS WOOD SPLIT,DECKING ROTTED.[SUBMIT PLANS AND PERMITS TO REPLACE] 7831 S COLFAX AVE PERIODIC FAILED View
REPAIR DOOR, INT. APARTMENT 2-S, APARTMENT DOOR; BROKEN. 7831 S COLFAX AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM 7831 REAR PORCH ANCHOR: STRINGER, COLUMN, BEAM, RAIL, ROTTEN DECK-1, 38" RAIL. 7831 S COLFAX AVE PERIODIC FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT / INTERIOR STAIR - 1ST FL TREADS LOOSE . 7831 S COLFAX AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING BASEMENT APT / CEILING - IN KITCHEN WATER DAMAGE 7831 S COLFAX AVE COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR PERMIT ONLY TO REPAIR PORCH 7831 S COLFAX AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO MOST UNITS. 7831 S COLFAX AVE PERIODIC FAILED View
PARAPET WEST ELEVATION / PARAPET WALL - WASHED OUT MORTAR. NORTH ELEVATION / PARAPET WALL - WASGED OUT MORTAR AND SPALLING BRCKS 7831 S COLFAX AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY 2ND FL APT / OBSTRUCITION - BURGLAR GATES. 7831 S COLFAX AVE COMPLAINT FAILED View
SERVICE WALK, PASSAGE, AREAWAY NORTH ELEVATION / AREAWAY - CEILING PVC 7831 S COLFAX AVE COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE BASEMENT APT /VIEWING DEVICE - MISSING. 7831 S COLFAX AVE COMPLAINT FAILED View
EXPOSED WIRING EXPOSED WIRE BATHROOM BASEMENT UNIT 7831 S COLFAX AVE COMPLAINT FAILED View
INSTALL COVERS OPEN JUNCTION BOX BATHROOM BASEMENT UNIT 7831 S COLFAX AVE COMPLAINT FAILED View
PARAPET WEST PARAPET WALL; OPEN JOINTS. 7831 S COLFAX AVE PERIODIC FAILED View
REPAIR SCREENS WINDOW SCREENS; TORN OR MISSING. 7831 S COLFAX AVE PERIODIC FAILED View