Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED ALL YEARS 1990 THROUGH 2014 YEARS . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE , UNVERIFIED CONDITIONS , OCCUPANCY AND DETECTORS . POSTED ENTRY NOTICES ALL ENTRY DOORS . ROLL OFF DUMPSTER BOX IN REAR YARD , NO CONSTRUCTION / DEMOLITION PERMITS OBTAINED . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN AND BOARDED WINDOWS AT NORTH AND SOUTH ELEVATIONS . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW SASH | ALL ELEVATIONS AND FLOORS , WOOD WINDOWS AND WOOD WINDOW SASHES BEHIND STORM WINDOWS ROTTED WITH FLAKING PAINT . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW | ALL ELEVATIONS AND FLOORS , WOOD WINDOW FRAMES ROTTED WITH FLAKING PAINT . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
REPAIR LINTELS | STOREFRONT IRON LINTEL ( "I" BEAM ) RUSTED AND DETERIORATED BOTTOM SUPPORT FLANGE . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | STOREFRONT ROTTED , DETERIORATED WITH FLAKING PAINT .SECOND FLOOR REAR SIDING MISSING TOP OF WALL . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR | STOREFRONT DOOR AND FRAME , ROTTED WITH FLAKING PAINT . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR, RESET | SOUTH ELEVATION METAL DOORS , RUSTED WITH FLAKING PAINT . WOOD ENTRY DOOR AND FRAME ROTTED WITH WORN AND WEATHERED FINISH . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH SERVICEWALK BROKEN , SHIFTED , LEANING TORARD BUILDING , TRIP AND FALL HAZARD . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
RAT PROOF EXTERIOR DOOR | TWO METAL DOORS AT SOUTH , RAT HOLES AT STOOP BASE . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
DEMO DEBRIS | NORTH YARD AND UNDER STAIRS , BRICKS , LOGS AND JUNK . RAT HARBORAGE . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
REPAIR ROOF | NORTH PORCH ROOF ,SAGGING WITH UNDERSIZED COLUMNS AND RAFTERS. | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | NORTH WOOD TWO STORY PORCH , REQUIRES PLANS AND PERMITS . UNKNOWN FOUNDATION STATUS WITH UPRIGHTS SET ON DIRT . COLUMNS NOTCHED AND DOUUBLE NOTCHED . RIM JOIST AND FLOOR JOIST UNDERSIZED AND OVERSPANNED AND ONLY NAILED . PLYWOOD DECKING UNAPPROVED AND UNDERSIZED . NO STAIR HEADER SUPPORT . STAIR RUN TOO LONG WITHOUT INTERMEDIATE LANDING . TREADS ONLY NINE INCHES WIDE . ALL HANDRAILS AND GUARDRAILS UNDERSIZED , WEAK AND ONLY NAILED . WORN AND WEATHERED FINISH . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
REPAIR/REBUILD GARAGE OR SHED | REAR FRAME GARAGE , SIDING , LOOSE , DENTED AND BUCKLED . TRIM , EAVES AND DOORS , ROTTED WITH FLAKING PAINT . RAFTER TAILS ROTTED , EAVE BOARDS MISSING . ROOF DECKING ROTTED AND WAVY AT EDGES . RAT HARBORAGE . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
REPAIR ROOF | NORTH PORCH ROOF , SAGGING WITH UNDERSIZED COLUMNS AND RAFTERS . | 6036 N MELVINA AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | ALL AREAS - MISSING CARBON MONOXIDE DETECTORS . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | ALL ELEVATIONS AND FLOORS - WINDOW FRAMES , GAPS AND CRACKS, DRAFTY WINDOWS , COLD AIR SEEPAGE . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | BASEMENT , MAIN BOILER AND OVERHEAD PIPES REMOVED AND DISCONNECTED . BOILER OUT OF SERVICE AT TIME OF INSPECTION . PERMIT REQUIRED FOR BOILER REPLACEMENT .REAR APARTMENT FIRST FLOOR , GAS SPACE HEATERS DISCONNECTED AND OUT OF SERVICE . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | REAR SECOND FLOOR APARTMENT - NO HEAT PROVIDED , BASEMENT BOILER AND PIPES REMOVED . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | FIRST FLOOR APARTMENT REAR PORCH STAIRS , BLOCKED BY JUNK AND DEBRIS . FIRE AND SAFETY HAZARD . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | REAR SECOND FLOOR APARTMENT - USING PORTABLE ELECTRICAL SPACE HEATERS FOR HEAT . NO BUILDING HEAT PROVIDED . BASEMENT BOILER AND OVERHEAD PIPES REMOVED . OVERUSE OF EXTENSION CORDS , FIRE AND SAFETY HAZARD . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | ALL AREAS - MISSING SMOKE DETECTORS . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | ALL AREAS , WALLS AND CEILINGS WATER DAMAGED WITH HOLES AND FLAKING PAINT AND PLASTER . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR SECOND FLOOR APARTMENT - SENIOR STOCKPILED ( HOARDING CONDITION ) WITH JUNK AND DEBRIS FROM FLOOR TO CEILINGS IN ALL ROOMS AND HALLS WITH ONLY SMALL EXIT PATHS . DANGEROUS AND HAZARDOUS TO TENANTS , OCCUPANTS AND FIRST RESPONDERS .FRONT FIRST FLOOR APARTMENT - NOT OCCUPIED AT TIME OF INSPECTION . ALSO STOCKPILED ( HOARDING CONDITION ) WITH JUNK AND DEBRIS FROM FLOOR TO CEILINGS IN ALL ROOMS AND HALLS WITH ONLY SMALL EXIT PATHS FIRE AND SAFETY HAZARD . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO FRONT SECOND FLOOR APARTMENT , UNVERIFIED CONDITIONS , OCCUPANCY AND DETECTORS . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | REAR SECOND FLOOR APARTMENT - DIRTY AND UNSANITARY WITH NOXIOUS ODORS . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
STOP SMOKE, NOXIOUS ODORS | REAR SECOND FLOOR APARTMENT - DIRTY AND UNSANITARY WITH NOXIOUS ODORS . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
NOTIFY DOB, USE OF VACANT LND | FRONT AND REAR FIRST FLOOR APARTMENT AND FRONT COMMERCIAL SPACE VACANT . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | BASEMENT CEILING REMOVED , EXPOSED WOOD FLOOR JOIST AND WOOD FLOOR SHEETING NOT FIRE RATED . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED | BASEMENT BOILER AND OVERHEAD HEATING PIPES REMOVED AND PUT OUT OF SERVICE . PERMIT REQUIRED FOR HEATING UNIT INSTALLATION REQUIRED . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQUIRED | BASEMENT SUPPORT BEAMS SAGGING AND DETERIORATED WITH SUPPORT COLUMNS REMOVED . TEMPORARY JACKS INSTALLED TO SUPPORT FLOOR AND BEAM , SET ON BASEMENT FLOOR WITHOUT FOUNDATIONS . PLANS AND PERMITS REQUIRED TO RESTORE STRUCTURAL MEMBERS . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
CHIMNEY | BASEMENT , METAL FLUE PIPES STUCK INTO CHIMNEY BASE AND FILLED WITH EXPANSION FOAM . FIRE AND SAFETY HAZARD . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
PRV DISCHARGE PIPE FROM PRV | BASEMENT WATER HEATER , MISSING OVERFLOW DISCHARGE PIPE . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | CENTER TWO STORY ENCLOSED PORCH REQUIRES PLANS AND PERMITS . UNKNOWN FOUNDATION STATUS . INTERIOR WALL FRAMING AND WALL SHEETING NOT FIRE RATED . UPRIGHTS UNDERSIZED . BEAMS , STRINGER AND JOIST ONLY NAILED TO COLUMNS . FLOOR JOIST AND RIM JOIST ONLY NAILED . NO WINDER OR STAIR HEADER SUPPORT . TREADS ONLY NINE INCHES . ALL GUARDRAILS AND HANDRAILS OVERSPANNED AND UNDERSIZED AND ONLY NAILED . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | NORTH YARD AND UNDER STAIRS , BRICKS , LOGS , JUNK AND DEBRIS . RAT HARBORAGE . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED ALL YEARS , 1990 THROUGH 2014 . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | ALL ELEVATIONS AND FLOORS , WOOD WINDOW FRAMES ROTTED WITH FLAKING PAINT . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | ALL ELEVATIONS AND FLOORS , WOOD WINDOWS AND WOOD WINDOWS BEHIND STORM WINDOWS , ROTTED WITH FLAKING PAINT AND PUTTY . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
RAT PROOF EXTERIOR DOOR | TWO METAL DOORS AT SOUTH , RAT HOLES AT STOOP BASE. | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | STOREFRONT DOOR AND FRAME , ROTTED WITH FLAKING PAINT . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | SOUTH ELEVATION METAL DOORS , RUSTED WITH FLAKING PAINT . WOOD ENTRY DOOR AND FRAME ROTTED WITH WORN AND WEATHERED FINISH . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | STOREFRONT ROTTED , DETERIORATED WITH FLAKING PAINT .REAR AT SECOND FLOOR , SIDING MISSING AT TOP OF WALL . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | STOREFRONT IRON LINTEL ( "I" BEAM ) RUSTED AND DETERIORATED BOTTOM SUPPORT FLANGE. | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH WOOD TWO STORY WOOD PORCH , REQUIRES PLANS AND PERMITS .UNKNOWN FOUNDATION STATUS WITH UPRIGHTS SET ON DIRT .COLUMNS NOTCHED AND DOUBLE NOTCHED . RIM JOIST AND FLOOR JOIST UNDERSIZED , OVERSPANNED AND ONLY NAILED . PLYWOOD DECKING UNDERSIZED AND NOT APPROVED . NO STAIR HEADER SUPPORT .STAIR RUN TOO LONG WITHOUT INTERMEDIATE LANDING . TREADS ONLY NINE INCHES WIDE .ALL HANDRAILS AND GUARDRAILS UNDERSIZED , WEAK AND ONLY NAILED . WORN AND WEATHERED FINISH .NORTH PORCH ROOF SAGGING . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | REAR FRAME GARAGE , SIDING , LOOSE , DENTED AND BUCKLED . TRIM , EAVES AND DOORS , ROTTED WITH FLAKING PAINT . RAFTER TAILS ROTTED , EAVE BOARDS MISSING . ROOF DECKING ROTTED AND WAVY AT EDGES . RAT HARBORAGE . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH AND SOUTH ELEVATIONS , WINDOW PANES BROKEN AND BOARDED . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH SERVICEWALKS , BROKEN , SHIFTED , LEANING TOWARD BUILDING , TRIP AND FALL HAZARD . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | NORTH ELEVATION/ GRADE TO 2ND FLOOR STAIR SYSTEM/ COLUMNS - DOUBLE NOTCHED FOR RIM JOISTS; ROTTED. UNDERSIZED 2X6 DECK JOIST SPANS 8 FEET. 2ND FLOOR LANDING - ONLY HAS ONE SINGLE UNDERSIZED 2X6 DECK JOIST. RIM JOISTS - ONLY NAILED TO COLUMNS. LEDGER BEAM - ONLY NAILED TO BUILDING'S EXTERIOR WALL. STRINGER - NOT FASTENED TO EXTERIOR WALL; EXCEEDS 12 FEET IN RISE HEIGHT. ALL RAILINGS - WEAK, LOOSE AND PULLING; ONLY NAILED TO COLUMNS AND POSTS. DECK FLOOR IS ROTTED PLYWOOD. DANGEROUS AND HAZARDOUS CONDITIONS.PLANS AND PERMIT REQUIRED TO REPLACE NORTH PORCH SYSTEM. | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | 2ND FLOOR FRONT UNIT WITH EXCESSIVE STORAGE AND JUNK THOUGH OUT UNIT. | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | REAR SECOND FLOOR APARTMENT - HOT WATER SHUT OFF . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | ALL AREAS , CEILINGS WATER DAMAGED FROM FLAT ROOF LEAKING . PERMIT REQUIRED . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | REAR SECOND FLOOR APARTMENT - OVER USE OF EXTENSION CORDS . FIRE HAZARD . | 6036 N MELVINA AVE | COMPLAINT | FAILED | View |