Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING /UNITS: 1, 2, 3, 5, 6, 7, 8, 9 - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS.UNABLE TO INSPECT INTERIOR STAIRWAY. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
REPAIR EAVES | ALL ELEVATIONS /EAVES-SOFFIT - ROTTED, WITH LARGE HOLES. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH ELEVATION /WOOD, CONCRETE AND METAL PORCHES. ALL FOUNDATIONS /COLUMNS ERECTED ON TOP FOUNDATIONS /COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES; FOUNDATION STATUS UNKNOWN; ALL LEDGER BEAMS /ATTACHED TO BUILDING EXTERIOR WALLS, WITH NAILS/SCREWS ONLY;/UNIT 1 - WOOD - DECKING /PLYWOOD USED AS DECKING MATERIAL [FOR UNENCLOSED EXTERIOR PORCH SYSTEM]; STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY; RAILINGS /GUARD RAILING SECTIONS UNDERSIZED, ARE OF LADDER TYPE DESIGN, WITH HORIZONTAL TIES SPACED UP TO 8 INCHES APART; - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; STAIR RAILING SECTIONS ARE OF LADDER TYPE DESIGN, WITH ANGLE TIES SPACED UP TO 8 INCHES APART; - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY;PERMIT REQUIRED TO REPLACE./UNIT 2 - WOOD - STAIRS /BOTTOM TREAD - MISSING. DECKING /DECK BOARDS, BUCKLED, ROTTED, LOOSE; STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY; RAILINGS /GUARD RAILING SECTIONS UNDERSIZED, ARE OF LADDER TYPE DESIGN, WITH HORIZONTAL TIES SPACED UP TO 8 INCHES APART; - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; STAIR RAILING SECTIONS ARE OF LADDER TYPE DESIGN, WITH ANGLE TIES SPACED UP TO 8 INCHES APART; - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY;PERMIT REQUIRED TO REPLACE. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 7834 S. /UNIT 3 - INTERIOR KITCHEN WALL AND CABINETS - WATER DAMAGE, WITH MILDEW.NOTE: SOUTH ELEVATION /UNIT 4 - EXTERIOR WALL - BUCKLED, BULGING BRICK, WITH WASHED OUT MORTAR. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION:/UNIT 1 - EXTERIOR WALL - BUCKLED, BULGING BRICK, WITH WASHED OUT MORTAR. MASONRY PERMIT REQUIRED TO REPAIR./UNIT 2 - EXTERIOR WALL - WASHED OUT MORTAR./UNIT 3 - EXTERIOR WALL - WASHED OUT MORTAR./UNIT 4 - EXTERIOR WALL - BUCKLED, BULGING BRICK, WITH WASHED OUT MORTAR.MASONRY PERMIT REQUIRED TO REPAIR./UNIT 9 - EXTERIOR WALL - LOOSE, MISSING BRICK, WITH WASHED OUT MORTAR. MASONRY PERMIT REQUIRED TO REPAIR. NORTH ELEVATION /UNIT 9 - EXTERIOR WALL - WASHED OUT MORTAR. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 7834 S. /UNIT 3 - SMOKE DETECTOR - MISSING. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 7834 S. /UNIT 3 - CARBON MONOXIDE DETECTOR - MISSING. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | SOUTH ELEVATION /EXCESSIVE JUNK AND DEBRIS. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | SOUTH ELEVATION /WEEDS OVER 2 FEET. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH ELEVATION [AT WEST] /METAL STAIR RAILS SECTIONS - MISSING. CONCRETE STEPS - SPALLING, WITH WASHED OUT STONE. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
REPAIR ROOF | SOUTH ELEVATION /UNIT 9 - ROOF - SECTIONS - MISSING WITH LARGE HOLES. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH ELEVATION /WOOD, CONCRETE AND METAL PORCHES. ALL FOUNDATIONS /COLUMNS ERECTED ON TOP FOUNDATIONS /COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES; FOUNDATION STATUS UNKNOWN; ALL LEDGER BEAMS /ATTACHED TO BUILDING EXTERIOR WALLS, WITH NAILS/SCREWS ONLY;/UNIT 3 - WOOD - STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY; ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY;PERMIT REQUIRED./UNIT 4 - WOOD - STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY; STRINGERS WEAK; STAIRS /RISER HEIGHT NOT UNIFORMED, RANGING FROM 7 INCHES TO 2 INCHES. RAILINGS /GUARD RAILING SECTIONS UNDERSIZED - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; STAIR RAILING SECTIONS - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY; PICKETS SPACED UP TO 7 1/2 INCHES APART.PERMIT REQUIRED TO REPLACE./UNIT 5 - WOOD RAILS - CONCRETE STOOP. RAILINGS /GUARD RAILING SECTIONS - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; STAIR RAILING SECTIONS - MISSING.ALL RAILING SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALL WITH NAILS /SCREWS ONLY; PICKETS SPACED UP TO 8 INCHES APART.PERMIT REQUIRED TO REPLACE./UNIT 7 - CONCRETE STOOP, WITH UNDERSIZED METAL GUARD RAILS. RAILINGS /METAL GUARD RAILS - UNDERSIZED. PICKETS SPACED UP TO 5 INCHES APART.PERMIT REQUIRED TO REPAIR./UNIT 8 - WOOD - STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY;/UNIT 9 - METAL GUARD RAILS - CONCRETE STOOP. RAILINGS /METAL RAILS UNDERSIZED LADDER TYPE. PERMIT REQUIRED TO REPAIR. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | NORTH ELEVATION /METAL CATWALK - STRUCTURAL MEMBERS INCLUDING BUT NOT LIMITES TO COLUMNS, BEAMS, CHANNELS, DECKING AND TOPPING. DISREPAIR, CORROSION AND RUST THROUGHOUT.SUBMIT PLANS AND PERMIT FOR REPAIR/REPLACMENT. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
EXPOSED WIRING | IN KICTHEN BEHIND STOVE,BASEMENT THROUGH-OUT DANGEROUS AND HAZADOUS | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL LIGHTS IN BASEMENT | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | REPAIR BURNED OUT BREAKER AT PANEL DANGERROUS AND HAZARDOUS | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
REPAIR LINTELS | SOUTH ELEVATION /ALL METAL LINTELS - RUSTED. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST EXTERIOR STAIRS - ERODED CONCRETE.SOUTH EXTERIOR STAIRS GRADE TO 1ST FLOOR - MISSING HANDRAILS AND PICKETS. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION - BROKEN GLASS PANE. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | DWELLING UNITS - NO RESPONSE, UNABLE TO VERIFY DETECTORS. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION - WASHED OUT MORTAR. | 7834 S SOUTH SHORE DR | COMPLAINT | FAILED | View |