PIN: 13164160150000
Property Address: 4101 N LEAMINGTON AVE
City - Zip: CHICAGO - 60641
2023 Property Class: 211
2023 Township: 71 - Jefferson
2023 Neighborhood: 71101
2023 Tax District: 71033
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 9 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING-NO RESPONSE,UNVERIFIED DETECTORS,UNABLE TO VERIFY COMPLAINT OF ILLEGAL BASEMENT APARTMENT. 4101 N LEAMINGTON AVE COMPLAINT CLOSED View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S I.D. SIGN POSTED . 4101 N LEAMINGTON AVE COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR FRONT PORCH AND REAR EXTERIOR BASEMENT STAIRS , MISSING HANDRAILS AND PROPER GUARDRAILS . 4101 N LEAMINGTON AVE COMPLAINT CLOSED View
REPAIR EAVES FRONT PORCH EAVES ROTTED AT SOUTH ELEVATION . 4101 N LEAMINGTON AVE COMPLAINT CLOSED View
PROVIDE GUTTER & DOWNSPOUT FRONT PORCH MISSING GUTTERS AND DOWNSPOUTS . 4101 N LEAMINGTON AVE COMPLAINT CLOSED View
REPAIR/REBUILD GARAGE OR SHED REAR GARAGE , SIDING ROTTED WITH FLAKING PAINT AT EAST ELEVATION . SERVICE DOOR ROTTED WITH PEELED WOOD . 4101 N LEAMINGTON AVE COMPLAINT CLOSED View
REPAIR PORCH SYSTEM REAR TWO STORY WOOD PORCH ALL COMPONENTS FLAKING PAINT . PLANS AND PERMITS REQUIRED . FOUNDATIONS UNKNOWN STATUS . UPRIGHTS ROTTED , NOTCHED AND DOUBLE NOTCHED . BEAMS UNDERSIZED AND ONLY NAILED TO COLUMNS . FLOOR JOIST OVERSPANNED AND UNDERSIZED . RIM JOIST OVERSPANNED AND ONLY NAILED TO COLUMNS . LANDING FLOOR JOIST ONLY NAILED TO RIM JOIST . NO STAIR HEADER SUPPORT , ONLY NAILED . ALL GUARDRAILS UNDERSIZED , WEAK , OVERSPANNED AND ONLY NAILED TO COLUMNS . 4101 N LEAMINGTON AVE COMPLAINT CLOSED View
INSPECT CONSTRUCTION WORK PERMIT # 100465133 ISSUED 12/4/2012 FOR REAR PORCH REPAIRS . NO PLANS AVAILABLE FOR INSPECTORS REVIEW AT TIME OF INSPECTION . NO WORK STARTED . 4101 N LEAMINGTON AVE COMPLAINT CLOSED View
REPAIR PORCH SYSTEM REAR TWO STORY PORCH, COLUMNS ARE ROTTED AT GRADE.FOUNDATION STATUS UNKNOWN.COLUMNS NOT ANCHORED TO BASES.COLUMNS - OVER NOTCHED WITH FIRE CUTS HAPPANING ONLY 6" APART FROM RIM JOIST NOTCH.UNDERSIZED 4"X6" BEAMS SPAN 6'-9".BEAMS ARE ONLY TOE NAILED TO COLUMNS.UNDERSIZED 2"X8" DECK JOISTS SPAN 10'-11-1/2" AND ARE 20" O.C..LANDING JOISTS ONLY FACE NAILED TO RIM JOISTS.STRINGERS ARE FASTENED TO JOISTS WITH NAILS ONLY.GUARD RAILINGS SECTIONS ARE ONLY 34" HIGHGUARD AND HANDRAILS ARE ONLY TOE NAILED TO 4"X4" RAILINGS POSTS AND COLUMNS.PLANS AND PERMIT ARE REQUIRED TO REPAIR OR REPLACE REAR PORCH. 4101 N LEAMINGTON AVE COMPLAINT CLOSED View