PIN: 20291100010000
Property Address: 7201 S ASHLAND AVE
City - Zip: CHICAGO - 60636
2023 Property Class: 100
2023 Township: 72 - Lake
2023 Neighborhood: 72170
2023 Tax District: 72001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 54 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# POST OWNER OR MANAGEMENT SIGN AT FRONT. 7201 S ASHLAND AVE COMPLAINT FAILED View
REPAIR CORNICE WEST ELEVATION- CORNICES MORTAR MISSING. 7201 S ASHLAND AVE COMPLAINT FAILED View
REPAIR LINTELS WEST ELEVATION - LINTEL RUSTED AND BENT. 7201 S ASHLAND AVE COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE - FASCIA IS LOOSE. 7201 S ASHLAND AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING- NO RESPONSE, UNVERIFIED DETECTORS.UNABLE TO INSPECT SECOND FLOOR KITCHEN FOR COMPLAINT OF SPONGY FLOOR. 7201 S ASHLAND AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS NO SMOKE DETECTORS IN STAIRWELL 7201 S ASHLAND AVE COMPLAINT FAILED View
CONNECT GAS APPLIANCE TO VENT 2ND FLOOR FORCED AIR FLUE 7201 S ASHLAND AVE COMPLAINT FAILED View
REPAIR / REBUILD SHED GARAGE - ROOF STRUCTURE - EXPOSED RAFTERS AND BADLY DETERIORATED, ROTTED ALSO EAVES ROTTED AND ERODED MORTAR JOINTS AT EAST ELEVATION. 7201 S ASHLAND AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR NEW GAS FIRED FORCED WARM AIR UNIT HEATER INSTALLED IN STORE. 7201 S ASHLAND AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FITTINGS MAKE PROPER CONNECTIONS AT 4" CAST IRON STACK OAKUM & POURED LEAD JOINTS AT STACK FEEDING 1ST FLOOR TOILET ROOMS, USE PROPER FITTING WHEN CONNECTIONG TO EXISTING HOUSE DRAIN IN BASEMENT AT STACK FEEDING 1ST FLOOR TOILET ROOM. 7201 S ASHLAND AVE COMPLAINT FAILED View
PROVIDE OPEN FRONT TOILET SEAT OPEN FRONT SEATS AT 1ST FLOOR TOILET ROOM 7201 S ASHLAND AVE COMPLAINT FAILED View
CONNECT GAS APPLIANCE TO VENT OPEN FLUE IN BASEMENT 7201 S ASHLAND AVE COMPLAINT FAILED View
INSTALL VENT PIPE FOR TRAP PROPERLY VENT (2) 3-COMPARTMENT SINKS AT 1ST FLOOR REAR 7201 S ASHLAND AVE COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL REMOVE PVC WASTE PIPING AT LAUNDRY TUB & 3-COMPARTMENT SINK 7201 S ASHLAND AVE COMPLAINT FAILED View
RESET LOOSE FIXTURE AT 3-COMPARTMENT SINK RAG RAPPED AROUND WASTE LINE 7201 S ASHLAND AVE COMPLAINT FAILED View
OBTAIN PERMIT FOR PLUMBING TO CORRECT ALL PLUMBING VIOLATIONS 7201 S ASHLAND AVE COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC A LICENSED & BONDED PLUMBING CONTRACTOR IS REQUIRED TO OBTAIN PERMIT 7201 S ASHLAND AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES LIGHT IN REAR AREA 1ST FLOOR 7201 S ASHLAND AVE COMPLAINT FAILED View
UNAPPROVED CORDS EXTENSION CORDS SOUTH WALL MIDDLE AREA 1ST FLOOR 7201 S ASHLAND AVE COMPLAINT FAILED View
CLOSE BOX OPENINGS UNUSED OPENING JUNCTION BOX SOUTH WALL 1ST FLOOR 7201 S ASHLAND AVE COMPLAINT FAILED View
UNAPPROVED CORDS EXTENSION CORDS NORTH WALL 1ST FLOOR 7201 S ASHLAND AVE COMPLAINT FAILED View
ARMORED CABLE BASEMENT GREENFIELD 7201 S ASHLAND AVE COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT BROKEN LB AT METER ON SERVICE ENTRY CONDUIT,REAR OF BUILDING 18-27-230.66,60 7201 S ASHLAND AVE COMPLAINT FAILED View
EXPOSED WIRING SERVICE ENTRY CONDUCTORS EXPOSED NEAR METER,BROKEN LB,REAR OF BUILDING DANGEROUS AND HAZARDOUS 18-27-300.4 7201 S ASHLAND AVE COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE 2ND FLOOR APARTMENT KITCHEN - OVEN USED TO HEAT THE ENTIRE APARTMENT. 7201 S ASHLAND AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS BASEMENT, 2ND FLOOR AT APARTMENT, FRONT AND REAR EXIT STAIRS - MISSING SMOKE DETECTORS. 7201 S ASHLAND AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT AND 2ND FLOOR APARTMENT - MISSING CARBON MONOXIDE DETECTORS. 7201 S ASHLAND AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY 2ND FLOOR APARTMENT - FURNACE NOT FUNCTIONING DURING TIME OF INSPECTION. ENTIRE APARTMENT HEATED WITH KITCHEN OVEN. 7201 S ASHLAND AVE COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT DEFECTIVE METER JUMPER OUT D&H 7201 S ASHLAND AVE COMPLAINT FAILED View
DEFECTIVE LIGHTING SERVICE DEFECTIVE PANEL IN BASEMENT D&H 7201 S ASHLAND AVE COMPLAINT FAILED View
DEFECTIVE OUTLETS DEFECTIVE OUTLET THROUGHOUT 2ND FLOOR REPAIR OUTLET TO EASE CORD USE D&H 7201 S ASHLAND AVE COMPLAINT FAILED View
CONTINUITY OF RACEWAY DEFECTIVE SERVICE ENTRANCE CONDUIT BROKEN D&H 7201 S ASHLAND AVE COMPLAINT FAILED View
APPLIANCE INSIGHT DISCONNECT NO SERVICE DISCONNECT FOR FURNACE 2ND FL D&H 7201 S ASHLAND AVE COMPLAINT FAILED View
CONTINUITY OF RACEWAY BROKEN CONDUIT THROUGHOUT BASEMENT 7201 S ASHLAND AVE COMPLAINT FAILED View
ADD RECEPTACLES NO SMOKE OR CO2 DETECTORS 570.10 H&I 7201 S ASHLAND AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES DEFECTIVE FIXTURES THROUGHOUT 2ND FL 7201 S ASHLAND AVE COMPLAINT FAILED View
INSTALL ILLUMINATION ADD LIGHTS TO ALL HALLS AND STAIRWAYS 7201 S ASHLAND AVE COMPLAINT FAILED View
REPLACE D&H PORCH ENCLOSED 2 STORY WOOD PORCH WITH BASEMENT ACCESS - (1) PORCH ROOF STRUCTURE AND ALL WOOD MEMBERS - ROTTED WITH WEAK FACE NAILED AND TOE NAILED CONNECTIONS. (2) CENTRAL BEAM SUPPORTING 2ND FLOOR JOIST HAS PULLED OUT OF THE COLUMN'S FIRE CUT. (3) STAIR STRINGER ATTACHED TO THE BUILDING'S EAST EXTERIOR WALL AND BETWEEN THE 1ST AND 2ND FLOOR IS WEAK, LEANING AND PULLING AWAY. (4) LOOSE GUARDRAILS AND HANDRAILS ARE ONLY 30 INCHES HIGH AND 24 INCHES HIGH, RESPECTIVELY. (5) EAST PORCH ELEVATION - MISSING DOWNSPOUT. (6) PLANS AND PERMITS REQUIRED. 7201 S ASHLAND AVE COMPLAINT FAILED View
FOUNDATION, ADEQUATELY SUPPORT REAR PORCH AT BASEMENT EAST CONCRETE 8 FEET HIGH RETAINING WALL - TWO COLLAPSED AREAS 4 FEET HIGH AND 6 FEET WIDE EXPOSING THE SOIL BEYOND AND RETAINING THE SOIL WITH NAILED FLIMSY PLYWOOD AND 2X4'S. PLANS AND PERMITS REQUIRED. 7201 S ASHLAND AVE COMPLAINT FAILED View
BUILDING IN DISREPAIR NORTHWEST CORNER ABOVE GROUND FLOOR COMMERCIAL SPACE ENTRY - STEEL BEAMS SUPPORTING MASONRY WALLS AND STRUCTURE ABOVE ARE RUSTED, DEFLECTING AND HAVE TEMPORARY WOOD POST SHORING WITHOUT LATERAL SUPPORT OR FOUNDATIONS. PLANS AND PERMITS REQUIRED. 7201 S ASHLAND AVE COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU BASEMENT CEILING - EXPOSED WOOD STRUCTURE MISSING FIRE RATED CONSTRUCTION. 7201 S ASHLAND AVE COMPLAINT FAILED View
DOOR SWING IN DIR. OF TRAVEL 2ND FLOOR APARTMENT FRONT ENTRY DOOR SWING OUT ONTO STAIR LANDING. 7201 S ASHLAND AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS BASEMENT, 2ND FLOOR APARTMENT, ENTRY STAIRWAY AND REAR ENCLOSED PORCH - MISSING SMOKE DETECTORS. 7201 S ASHLAND AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT AND 2ND FLOOR APARTMENT - MISSING CARBON MONOXIDE DETECTORS. 7201 S ASHLAND AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING 2ND FLOOR APARTMENT - (1) KITCHEN LAY-IN CEILING TILES - 1 HANGING AND 3 MISSING PANELS. (2) SUNROOM CEILING - CRACKED AND HANGING PLASTER. (3) BASEMENT WALLS - NUMEROUS HOLES WITH DARK, MOLD-LIKE SPOTS. 7201 S ASHLAND AVE COMPLAINT FAILED View
VACANT BUILDING - REGISTER 7201 S ASHLAND AVE COMPLAINT CLOSED View
REPAIR INTERIOR WALLS/CEILING 1ST FLOOR CEILING WATER DAMAGE CEILING TILE 7201 S ASHLAND AVE COMPLAINT FAILED View
UNAPPROVED CORDS 2ND FLOOR EXTENSION CORD LIVING ROOM 7201 S ASHLAND AVE COMPLAINT FAILED View
UNAPPROVED CORDS EXTENSION CORD 1ST FLOOR NORTH WALL KITCHEN AREA 7201 S ASHLAND AVE COMPLAINT FAILED View
BOX UNUSED OPENINGS BASEMENT UNUSED OPENINGS 7201 S ASHLAND AVE COMPLAINT FAILED View
REPAIR FLOOR 1ST FLOOR FLOOR AREA LOOSE TILES. 7201 S ASHLAND AVE COMPLAINT FAILED View
STOP/REMOVE NUISANCE REAR YARD WEEDS & DEBRIS 7201 S ASHLAND AVE COMPLAINT FAILED View
EXPOSED WIRING EXPOSED WIRES THROUGHOUT BASEMENT D&H 7201 S ASHLAND AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM WEST BASEMENT WOOD STAIR UP TO GROUND FLOOR COMMERCIAL SPACE - ROTTEN, PARTIALLY COLLAPSED, MISSING HANDRAILS AND RISERS. PERMIT REQUIRED. 7201 S ASHLAND AVE COMPLAINT FAILED View