Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 4:02 AM
PIN: 20251200020000
Property Address: 7205 S BENNETT AVE
City - Zip: CHICAGO - 60649
2023 Property Class: 315
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70080
2023 Tax District: 70131
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 36 Violations
Violation Inspector Comments Address Category Status View
MICE/RODENTS 2ND FLOOR APARTMENT AT 7205 CLAIMS MICE 7205 S BENNETT AVE PERIODIC FAILED View
ROACHES 2ND FLOOR APARTMENT AT 7805 CLAIMS ROACHES 7205 S BENNETT AVE PERIODIC FAILED View
USE SANITARY REFUSE CONTAINERS REAR ELEVATION TRASH OUT OF CONTAINERS 7205 S BENNETT AVE PERIODIC FAILED View
INSTALL SMOKE DETECTORS INTERIOR STAIRWELL AT 7205 BEEPING DETECTOR 7205 S BENNETT AVE PERIODIC FAILED View
CHIMNEY CHIMNEY OPEN JOINTS 7205 S BENNETT AVE PERIODIC PASSED View
REPAIR PORCH SYSTEM REAR PORCH SYSTEM MISSING BOLTS AND METAL HANGERS 7205 S BENNETT AVE PERIODIC FAILED View
RATS 7205 BASEMENT UNIT IS 58 DEGREES IN ROOM 1 AND 59 DEGREES IN ROOM 2 7205 S BENNETT AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM SR# 900218651, 7205- JOIST OVER SPANNED, STRINGERS UNDERSIZED CRACKED NOT BOLTED, COLUMNS BOWED, OVER NOTCHED. 7207-MID LANDINGS PULLING AWAY FROM MASONRY WALL, COLUMNS BOWED, NO SPLICE JOINTS, STRINGERS ROTTED CRACKED AND PULLING, JOISTS SPACED OVER 16 INCHES ON CENTER, 7211- RAIL SECTIONS WEAK, COLUMNS OVER NOTCHED, DECKING ROTTED, 7213-JOISTS OVER SPANNED, NO BOLTED CONNECTIONS, NO JOIST HANGERS, OBTAIN PLANS AND PERMITS TO REPAIR OR REPLACE 4 PORCH SYSTEMS. 7205 S BENNETT AVE PERIODIC PASSED View
REPAIR COPING COPING STONES AT NORTHWEST COURT YARD LOOSE FRACTURED. 7205 S BENNETT AVE PERIODIC PASSED View
HEAT UNIT ADEQUATELY 2W 60 DEGREES 7205 S BENNETT AVE COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE USING STOVES FOR HEAT. 7205 S BENNETT AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY IN ADEQUATELY HEATED 58DG 7205 2ND FLOOR UNIT. 7205 S BENNETT AVE COMPLAINT FAILED View
REPAIR CORNICE COURT YARD / CORNICE - OPEN MORTAR JOINT . 7205 S BENNETT AVE PERIODIC FAILED View
REPAIR COPING COPING STONES AT NORTHWEST COURT YARD LOOSE FRACTURED. 7205 S BENNETT AVE PERIODIC PASSED View
REPAIR PORCH SYSTEM SR# 900218651, 7205- JOIST OVER SPANNED, STRINGERS UNDERSIZED CRACKED NOT BOLTED, COLUMNS BOWED, OVER NOTCHED. 7207-MID LANDINGS PULLING AWAY FROM MASONRY WALL, COLUMNS BOWED, NO SPLICE JOINTS, STRINGERS ROTTED CRACKED AND PULLING, JOISTS SPACED OVER 16 INCHES ON CENTER, 7211- RAIL SECTIONS WEAK, COLUMNS OVER NOTCHED, DECKING ROTTED, 7213-JOISTS OVER SPANNED, NO BOLTED CONNECTIONS, NO JOIST HANGERS, OBTAIN PLANS AND PERMITS TO REPAIR OR REPLACE 4 PORCH SYSTEMS. 7205 S BENNETT AVE PERIODIC PASSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING- NO ENTRY TO COMPLETE ANNUAL INSPECTION. NO ENTRY TO INTERIOR OR EXTERIOR STAIR SYSTEM. 7205 S BENNETT AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING - NOT REGISTERED FROM 2013 THROUGH 2016. 7205 S BENNETT AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING - NOT REGISTERED FROM 2013 THROUGH 2016. 7205 S BENNETT AVE PERIODIC FAILED View
REPAIR CORNICE WEST ELEVATION AND FRONT COURTYARD CORNICE - WASHED OUT MORTAR AT JOINTS. 7205 S BENNETT AVE PERIODIC FAILED View
NO POSTED ADDRESS BUILDING - POST COMPLETE ADDRESS RANGE OF BUILDING SO IT'S VISIBLE FROM THE STREET. 7205 S BENNETT AVE PERIODIC FAILED View
REPAIR COPING WEST ELEVATION AND FRONT COURTYARD COPING - WASHED OUT MORTAR AT JOINTS. 7205 S BENNETT AVE PERIODIC FAILED View
REPAIR CORNICE WEST ELEVATION AND FRONT COURTYARD CORNICE - WASHED OUT MORTAR AT JOINTS. 7205 S BENNETT AVE PERIODIC FAILED View
CHIMNEY SOUTH ELEVATION / CHIMNEY - MISSING BRICKS AND WASHED OUT MORTAR. 7205 S BENNETT AVE PERIODIC FAILED View
REPAIR WINDOW SILLS WEST ELEVATION / WINDOW SILL - OPEN JOINTS. 7205 S BENNETT AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INSP FOR CONDITIONS AND DETECTORS. 7205 S BENNETT AVE PERIODIC FAILED View
REPAIR SCREENS ALL ELEVATIONS - TORN WINDOW SCREENS. 7205 S BENNETT AVE PERIODIC FAILED View
REPAIR CORNICE ALL ELEVATION/ CORNICE - LARGE OPEN MORTAR GAPS . 7205 S BENNETT AVE PERIODIC FAILED View
NO POSTED ADDRESS BUILDING - POST COMPLETE ADDRESS RANGE OF BUILDING SO IT'S VISIBLE FROM THE STREET. 7205 S BENNETT AVE PERIODIC FAILED View
REPAIR SCREENS ALL ELEVATIONS - TORN WINDOW SCREENS. 7205 S BENNETT AVE PERIODIC FAILED View
REPAIR COPING WEST ELEVATION AND FRONT COURTYARD COPING - WASHED OUT MORTAR AT JOINTS. 7205 S BENNETT AVE PERIODIC FAILED View
CHIMNEY CAPPING SOUTH ELEVATION / CHIMNEY CAP - MISSING. 7205 S BENNETT AVE PERIODIC FAILED View
REPAIR COPING ALL ELEVATION / COPING - OPEN MORTAR JOINTS. 7205 S BENNETT AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INSP FOR CONDITIONS AND DETECTORS. 7205 S BENNETT AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL COURT YARD / EXTERIOR WALL - 1 STF COLUMNS WASHED OUT MORTAR 7205 S BENNETT AVE PERIODIC FAILED View
REPAIR STOOP 7209/07 COURT YARD / FRONT STOOP BROKEN 7205 S BENNETT AVE PERIODIC FAILED View
REPAIR SCREENS FRONT/ SCREENS- TORN 7205 S BENNETT AVE PERIODIC FAILED View