Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | 900723061 2 STORY WOOD STAIR SYSTEM STAIR RAILS HAVE LADDER TYPE DESIGN, STRINGER AND WINDER ARE TOENAILED TO RIM JOIST,COLUMNS SITTING ON CONCRETE SLAB SUBMIT PLAN AND OBTAIN PERMIT BEFORE REPAIRING OR REPLACING STAIR SYSTEM | 7530 S EGGLESTON AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERSHIP POSTED | 7530 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEDVATION / 2 STORY WOOD PORCH / COLUMNS - ERECTED ON CONCRETE BLOCKS. FOUNDATION STATUS - UNKNOWN. 4X4 COLUMNS - ROTTING AND SPLIT. 2X8 JOISTS - SPACED ON 24 INCH CENTERS. 2ND FLOOR DECK IS OUT OF LEVEL UP TO 3 INCHES. STAIR STRINGERS ARE FASTENED TO COLUMNS WITH NAILS ONLY. WINDER STRINGERS - FASTENED WITH NAILS TO THE OTHER STRINGER. WINDER STRINGERS - ROTTING AND SPLITTING. STAIR TREADS - ROTTING, SPLITTING AND WEAK. RISERS - ROTTING AND PULLING AWAY FROM STRINGERS. HAND RAILING AT WINDERS IS LADDER TYPE WITH GAPS UP TO 14 INCHES. WINDER HANDRAIL FROM 1ST TO 2ND FLOOR - FASTENED WITH NAILS ONLY. 1ST FLOOR GUARD RAIL - LOOSE AND PULLING. PICKETS MISSING AT VARIUOUS LOCATIONS. PLANS AND PERMIT REQUIRED TO REPAIR 2 STORY WOOD PORCH. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 7530 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | WEST ELEVATION GARAGE MAJOR HOLES IN ROOF AND WALLS ROTTED SHEATHING AND ASPHALT SIDING,BROKEN SECURE AND OVERHEAD DOOR | 7530 S EGGLESTON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEDVATION / 2 STORY WOOD PORCH / COLUMNS - ERECTED ON CONCRETE BLOCKS. FOUNDATION STATUS - UNKNOWN. 4X4 COLUMNS - ROTTING AND SPLIT. 2X8 JOISTS - SPACED ON 24 INCH CENTERS. 2ND FLOOR DECK IS OUT OF LEVEL UP TO 3 INCHES. STAIR STRINGERS ARE FASTENED TO COLUMNS WITH NAILS ONLY. WINDER STRINGERS - FASTENED WITH NAILS TO THE OTHER STRINGER. WINDER STRINGERS - ROTTING AND SPLITTING. STAIR TREADS - ROTTING, SPLITTING AND WEAK. RISERS - ROTTING AND PULLING AWAY FROM STRINGERS. HAND RAILING AT WINDERS IS LADDER TYPE WITH GAPS UP TO 14 INCHES. WINDER HANDRAIL FROM 1ST TO 2ND FLOOR - FASTENED WITH NAILS ONLY. 1ST FLOOR GUARD RAIL - LOOSE AND PULLING. PICKETS MISSING AT VARIUOUS LOCATIONS. PLANS AND PERMIT REQUIRED TO REPAIR 2 STORY WOOD PORCH. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 7530 S EGGLESTON AVE | COMPLAINT | CLOSED | View |