Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT PORCH GUARDRAIL RUSTED BENT EXCESSIVE SPACING AND TOO SHORT SHOULD BE 42 INCHES HANDRAIL TOO SHORT SHOULD BE 34 INCHES AND RUSTED STEEL COLUMN RUSTED DETACHED FROM BEAM, 4X4 BEAM SPLIT AND BOWED | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH AND EAST ELEVATION OPEN AND SPALLING AND VERTICAL CRACKS | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | EAST ELEVATION ROOF OVER FRONT PORCH SAGGING | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION 1ST FLOOR WINDOW MISSING VARIOUS WINDOW BROKEN AND OR CRACKED | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | EAST ELEVATION FASCIA BOARD EXPOSED AND ROTTED | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PORCH, NO FOOTINGS 4X4 COLUMNS BOWED, DAMAGED NAILED JOIST BOWED NO HANGERS 2X10 BEAM DAMAGED RAILS GUARDRAIL TOO SHORT SHOULD BE 42 INCHES EXCESSIVE SPACING BETWEEN PICKETS SOME PICKETS MISSING OPEN RISERS DESIGN (RISERS MISSING) PROVIDE PLANS AND PERMIT FOR REPLACEMENT OR PORCH BEFORE PERFORMING WORK | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | REAR GARAGE STEEL OVER OVERHEAD SAGGING VERTICAL FRACTURE, MISSING COPING TILE | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | SOUTH ELEVATION DOWNSPOUT MISSING (18-29-1101.21.1) | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | REAR 2ND FLOOR LANDING, EXCESSIVE STORAGE FURNITURE, GRILLS, ETC | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | REAR SIDING PEELING AND DAMAGED | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | ALL WINDOW FRAMES ROTTED | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EXTERIOR FRONT PORCH RETAINING WALL SPALLED CONCRETE, AND LOOSE BRICKS. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
REPAIR DEFECTIVE FOUNDATION | EXTERIOR FOUNDATION WALLS SPALLED BRICK AND WASHED OUT MORTAR JOINTS. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
ARRANGE FOR REINSPECTION REGAR | PERMIT 100271189 DATED 3.19.2012 NO ACTIVITY FOR FRONT AND REAR PORCH. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
STOP/REMOVE NUISANCE | EXTERIOR FRONT PORCH EXCESSIVE STORAGE OF FURNITURE. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW | EXTERIOR ALL WINDOWS ROTTED AND FLAKING PAINT | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | EXTERIOR WINDOW CRACKED WINDOW PANE. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
REPAIR ROOF | EXTERIOR ROOF WORN SHINGLES. | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | EXTERIOR FENCE MISSING TOP RAIL. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE WASHED OUT MORTAR JOINTS AND LARGE STRESS FRACTURES. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | (ALL ELEVATIONS) EXTERIOR WALLS - LOOSE,BULGING,MISSING MORTAR SKIMCOAT. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
REPLACE D&H PORCH | (WEST ELEVATION)REAR STAIR SYSTEM(2 STORY ATTACHED TO WOOD FRAMED ENCLOSURE) LEDGERS ARE NOT BOLTED TO THE ENCLOSURE WALL,LARGE GAPS IN BETWEEN THE LEDGERS AND ENCLOSURE.FLIGHT OF STAIRS FROM GRADE TO 2ND FLOOR SHIFTS LATERALLY UPON LOAD.ENCLOSURE IS SEPERATING FROM THE BUILDING,LARGE GAPS IN THE MORTAR SKIMCOAT.ALL RAILS ARE ONLY TOE SCREWD INTO THE COLUMN/POST CONNECTIONS.FOUND STATUS IS UNKNOWN.SUBMIT PLANS/ OBTAIN PERMIT FOR PORCH REPAIRS. | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | ACCUMULATION OF JUNK,DEBRIS AND USED LUMBER PILED UNDERNEATH THE REAR PORCH ENCLOSURE. | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | (WEST ELEVATION)REAR STAIR SYSTEM(2 STORY ATTACHED TO WOOD FRAMED ENCLOSURE) LEDGERS ARE NOT BOLTED TO THE ENCLOSURE WALL,LARGE GAPS IN BETWEEN THE LEDGERS AND ENCLOSURE.FLIGHT OF STAIRS FROM GRADE TO 2ND FLOOR SHIFTS LATERALLY UPON LOAD.ENCLOSURE IS SEPERATING FROM THE BUILDING,LARGE GAPS IN THE MORTAR SKIMCOAT.ALL RAILS ARE ONLY TOE SCREWD INTO THE COLUMN/POST CONNECTIONS.FOUND STATUS IS UNKNOWN.SUBMIT PLANS/ OBTAIN PERMIT FOR PORCH REPAIRS. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
NO CLOSET/STORAGE UNDER STAIR | ACCUMULATION OF JUNK,DEBRIS AND USED LUMBER PILED UNDERNEATH THE REAR PORCH ENCLOSURE. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
CHIMNEY | EXTERIOR CHIMNEY BRICKS WASHED OUT MORTAR JOINTS. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
REPAIR ROOF | EXTERIOR ROOF WORN SHINGLES. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
STRUCTURAL MEMBER, PIER BLOCK | BASEMENT - CENTER BUILDING SUPPORT BEAM WAS ALTERED.TRUMPERY SCREW TYPE FLOOR JACKS ARE UTILIZED FOR SUPPORT AND COLMNS WERE CUT AND ARE NOW RESTED ON TOP OF A MASONRY WALL THAT WAS ERECTED WITHOUT FOOTINGS.THE WALL IS BOWING SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIRS. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
EXPOSED WIRING | BASEMENT CIRCUIT BREAKER CAGINESS ARE MISSING ACCESS PANELS,EXPOSED COMPONENTS. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
REPUTTY WINDOW PANES | ALL WINDOW PUTTY MISSING AND DRIED OUT. | 6712 S LAFAYETTE AVE | COMPLAINT | CLOSED | View |
CHIMNEY | EXTERIOR CHIMNEY BRICKS WASHED OUT MORTAR JOINTS. | 6712 S LAFAYETTE AVE | COMPLAINT | FAILED | View |