Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 10:16 PM
PIN: 13362310100000
Property Address: 2022 N WESTERN AVE
City - Zip: CHICAGO - 60647
2023 Property Class: 315
2023 Township: 77 - West Chicago
2023 Neighborhood: 77030
2023 Tax District: 77138
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 4 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM REINSPECTION REAR COLUMN IS RESIED ON A CONCRETE BASE, IS TWISTED, OUT OF PLUMR AND ONLY A 7 INCH SPLICE, FOUNDATION STATUS IS UNKNOWN. BEAM POCKETS WITH MISSING STRAPS AND MORTAR. LOOSE TREADS AND RISERS- LOOSE HAND AND GUARD RAILS. GUARD RAILS WITH ONLY HORIZONTIAL 2X4 MEMBERS FOR PICKETS, AND OVERSPACED. GUARD RAILS NOTICEABLY DEFLECT UPON LOAD. STAIRS SWAY BETWEEN 2 AND 3 UPON LOAD. ROTTED STAIRS POST AT GRADE. ROTTED FACE BEAM AT 2. IMPROPER CONNECTIONS- MOST MEMBERS ARE TOE NAILED TOGETHER AND ARE SEPERATED AT THE CONNECTIONS. MISSING HAND RAIL FROM G TO R. PLANS AND PERMIT ARE REQUIRED FOR REPLACEMENT. 2022 N WESTERN AVE COMPLAINT PASSED View
PROVIDE GUARD RAIL 42 IN HIGH REAR 2 STAIRS SYSTEMS FROM G TO B MISSING GUARD RAILS AROUND THE PERIMETER OF STAIRWAY OPENINGS. 2022 N WESTERN AVE COMPLAINT PASSED View
FIRE EXTNGSHR RECHARGE & TAG ALL INTERIOR STAIRWAY EXPIRED SERVICE TAGS. 2022 N WESTERN AVE COMPLAINT PASSED View
REPAIR EXTERIOR STAIR REAR COLUMNS ARE RESTED ON CONCRETE, FOUNDATION STATING IS UNKNOWN. LEDGER IS ONLY NAILED INTO THE BUILDING. LOOSE TREADS, RISERS, HAND AND GUARD RAILS. ENTIME SYSTEM SWAYS UPON WAD. GUARD RAILS NOTICEABLY DEFLECT UPON LOAD. IMPROPER CONNECTIONS- MOST MEMBRES ARE TOE NAILED TOGETHER AND ARE SEPERATED AT THE CONNECTIONS. MISSING HANDRAIL FROM G TO R. PLANS PERMIT ARE REQUIRED FOR REPLACEMENT. 2022 N WESTERN AVE COMPLAINT PASSED View