Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | ABOVE THE (5) STOREFRONT WINDOWS, THE SOLDIER COURSE BRICKWORK IS DISPLACED / TIPPED OUTWARD OVER THE PUBLIC WAY. DANGEROUS AND HAZARDOUS.SECTION 14X-3-303.1.1. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
REPAIR EXTERIOR WALL | ABOVE THE (6) STOREFRONT WINDOWS, THE SOLDIER COURSE BRICKWORK IS DISPLACED / TIPPED OUTWARD OVER THE PUBLIC WAY. ALSO, THE REAR BRICK WALL HAS BEEN COVERED IN VINYL SIDING. THIS SIDING HAS BECOME LOOSE / DETACHED AND IS FALLING AWAY FROM THE MAIN BRICK WALL.DANGEROUS AND HAZARDOUS.SECTION 14X-3-303.1.1. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | NETWORKS TO BE GROUPED AND IDENTIFIED 14E-2-200.4B | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
PERFRM STRUCT ENGINEER REPAIRS | THE STRUCTURAL LINTELS SUPPORTING THE FRONT BRICKWORK OF THESE 5 ADJOINING STOREFRONTS CANNOT BE SEEN; YET THE BRICKWORK ABOVE IS DISPLACED. REMOVE THE METAL CLADDING SO AS TO INSPECT THE CONDITION OF THE STRUCTURAL LINTELS FROM 5616 TO 5624.SECTION 14X-1-104.1. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | IT WAS OBSERVED AT THE TIME OF THIS INSPECTION THAT THERE WAS EXPOSED WIRTING INSIDE 5624. ALSO, THE (REAR) SERVICE PIPE IS FALLING OFF THE BUILDING. THE FASTENERS HAVE FAILED. ALSO, AT A POINT WHERE A PIPE UNION HAS FAILED, WATER IS ENTERING THIS SERVICE PIPING FROM A LEAKING GUTTER DIRECTLY ABOVE. DANGEROUS AND HAZARDOUS.THIS ELECTRICAL SERVICE IS FOR ALL 6 COMMERCIAL SPACES (5616, 5618, 5620, 5622, 5622 1/2 AND 5624). A FULL CBI WITH A TASK FORCE (TEAM ... ELECTRICAL INSPECTOR) IS REQUIRED. SECTION 14X-7-7-3 / 705. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | THE UNLICENSED PARTY VENUE HAS SEVERELY UNSAFE MEANS OF EGRESS OBSTRUCTIONS. THE REAR DOOR FOR 5624 HAS BEEN COVERED WITH DRYWALL. THE REAR DOOR AT 5622 1/2 WAS KEYLOCKED WITH A BEVERAGE MACHINE IN FRONT OF THE DOOR. ALL 3 FRONT EXIT DOORS WERE KEY LOCKED LEAVING ONLY 1 USABLE EXIT DUTING AN UNLICENSED EVENT WITH OVER 150 ATTENDEES. EXTREME HAZARD. SECTION 14X=5=505.1.2H | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | 5 OF 6 EXIT DOORS REQUIRE A KEY TO EXIT. DANGEROUS AND HAZARDOUS. SECTION 14X-5-505.1.2.2. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTORS. DANGEROUS AND HAZARDOUS. SECTION 14X-5-504.8. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | NO CARBON MONOXIDE DETECTORS. DANGEROUS AND HAZARDOUS. SECTION 14X-5-504.9. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | THESE 3 ADJOINING COMMERCIAL UNITS (5622, 5622 1/2, 5624) HAVE BEEN ALTERED INTO ONE, SINGLE EVENT SPACE. PARTITION WALLS WERE REMOVE TO ACCOMPLISH THIS ALTERATION AS WELL AS OTHER PARTITION WALLS ADDED TO FORM BATHROMOMS, ETC ... THERE IS NEW ELECTRICAL / PLUMBING WIRING / PIPING AND FIXTURES. ALL OF THIS WORK WAS PERFORMED WITHOUT PLANS / PERMITS / ZONING AUTHORIZATION. ALSO, THERE HAS BEEN A CHANGE OF USE FROM 3 INDIVIDUAL STORE FRONTS (5622, 5622 1/2, 5624) TO 1 UNLICENSED EVENT SPAVE WITH PPA ACTIVITY (5622-5624). THERE WAS A COVER CHARGE AT THE DOOR, LIVE DJ MUSIC WITH ALCOHOL / FOOD SERVED / SOLD. A BACP AND DOB CLOSURE WAS ISSUED. 14A-4-401.1. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL WORK PERFORMED WITHOUT PLANS / PERMITS. SECTION 14A-4-401. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | THE (WEST) FENCE HAS BEEN INSTALLED WITHOUT PERMIT. SECTION 14A-4-401. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | THE GAS FIRED FURNACE (CLOSETS) ARE ALSO BEING USED FOR (FLAMMABLE) STORAGE OF ITEMS. DANGEROUS AND HAZARDOUS. SECTION 14X-1-103. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
DEFECTIVE SERVICE | REPLACE DEFECTIVE SERVICE EXTERIOR | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
ELECTRICAL PERMIT REQUIRED 14A-4-404.6 | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
EXPOSED WIRING | THROUGHOUT | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
PANEL SCHEDULES | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
MULTIPLE CONDUCTOR TERM | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
SECURE RACEWAY | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
DEFECTIVE OUTLETS | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
INSTALL COVERS | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
SEE INSPECTOR COMMENTS | SHOW WINDOW RECEPTACLE REQUIRED 14E-2-210.62 | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
REMOVE EXPOSED CABLE | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
STRUCTURAL MEMBER, PIER BLOCK | BREACH IN DEMISSING WALL SEPERATING 5622-5624 EXTERIOR WALL/PARAPET SHOWS SIGNS OF FACE BRICK SEPERATING AWAY FROM COMMON BRICK.THIS IS OVER THE PUBLIC WALKWAY. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
CIRCUIT BREAKERS TO BE LISTED FOR USE WITH PANELBOARD 14E-110.3 (B) | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
SYSTEM III | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
STRUCTURAL MEMBER, PIER BLOCK | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
SMOKE & CARBON DETECTORS | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
CORD TO FIXTURE | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
REPAIR EXTERIOR WALL | ABOVE THE (6) STOREFRONT WINDOWS, THE SOLDIER COURSE BRICKWORK IS DISPLACED / TIPPED OUTWARD OVER THE PUBLIC WAY. ALSO, THE REAR BRICK WALL HAS BEEN COVERED IN VINYL SIDING. THIS SIDING HAS BECOME LOOSE / DETACHED AND IS FALLING AWAY FROM THE MAIN BRICK WALL.DANGEROUS AND HAZARDOUS.SECTION 14X-3-303.1.1. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
WORKING SPACE | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
ACCESS TO JBS | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
CONTINUITY OF RACEWAYS | LOOSE FITTINGS/SE RACEWAY FLOATING IN PANELBOARD | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
PROTECT SIDEWALK DURING CONST | PROVIDE SAFETY CANOPY FOR SOUTH END OF PROPERTY. CANOPY SHOULD SPAN FROM 5616-5624. FACEBRICK PULLING AWAY FROM COMMON BRICK OVER PUBLIC WAY - DANGEROUS AND HAZARDOUS. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
CLOSE BOX OPENINGS | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
INSTALL GFCI'S | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
ELECTRICAL PERMIT REQUIRED 14A-4-404.6 | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
PROPER SIZE OCP | 5624 W DIVISION ST | COMPLAINT | FAILED | View | |
ARRANGE FOR REINSPECTION REGAR | THERE HAVE BEEN NUMEROUS CPD COMPLAINTS REGARDING ONGOIN LARGE, UNLICENSED EVENTS AT THIS SERIES OF STOREFRONT COMMERCIAL SPACES. THIS TASK FORCE, AFTED OBSERVING LARGE GATHERINGS OF PEOPLE OUT FRONT WAITING TO ENTER, ATTEMPTED ENTRY, BUT HAD THE DOOR SLAMMED ON US EACH TIME. AN INTERIOR INSPECTION IS REQUIRED TO DETERMINE THE SAFETY OF THIS UNLICENSED VENUE.SECTION 14A-1-104.7. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
INSTALL COVERS | INSTALL COVER ON OUTLET OR JUNTION BOX. EXTERIOR | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
LISTED FOR USE TEMP & LOCATION | ELECTRICAL EQUIPMENT SHALL BE LISTED FOR USE, TEMPERATURE AND LOCATION. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
INSTALL EXIT SIGN | NUMEROUS MISSING / INOPERABLE ILLUMINATED EXIT SIGNS. DANGWEROUS AND HAZARDOUS. SECTION 14X=5-505.6.2. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | REMOVED EXPOSED WIRING. | 5624 W DIVISION ST | COMPLAINT | FAILED | View |