Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR DOOR | WEST SECURITY ENTRANCE DOOR 1ST FLOOR BROKEN AND RUSTED SECTIONS | 1111 N MONITOR AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | ROTTED WINDOW SILLS BASEMENT NORTH AND SOUTH | 1111 N MONITOR AVE | COMPLAINT | FAILED | View |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS | 1111 N MONITOR AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | OPEN MORTAR JOINTS AT CHIMNEY CAP ONLY VIEWABLE FROM REAR YARD | 1111 N MONITOR AVE | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | LOOSE AND MISSING WINDOW PUTTY BASEMENT AND 1ST FLOOR NORTH AND SOUTH | 1111 N MONITOR AVE | COMPLAINT | FAILED | View |
SECURE RACEWAY | PROPERLY SUPPORT LOW VOLTAGE WIRING AROUND BUILDING -- | 1111 N MONITOR AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ONE STORY FRAME PORCH. OVER SPACED PICKETS, UNDERSIZED GUARD RAILS, ROTTED TONGUE AND GROOVE FLOORING, GUARD RAILS ARE LOOSE HAND RAILS ARE LOOSE MISSING TREAD NOSING | 1111 N MONITOR AVE | COMPLAINT | FAILED | View |
PROV 1"AIR GAP ABV OVRFLW RIM | TUB SPOUT MUST BE 1" ABOVE SPILL LINE OF FIXTURE. | 1111 N MONITOR AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | EAVES NORTH AND SOUTH HAS SOME ROTTED AND SOME MISSING SECTIONS EAST MISSING EAVE SECTION | 1111 N MONITOR AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT AT EXTERIOR FRONT PORCH AND REAR AREA'S OF BUILDING -- | 1111 N MONITOR AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | SOUTH CHAIN LINK FENCE OUT OF PLUMB DISCONNECTED SECTIONS | 1111 N MONITOR AVE | COMPLAINT | FAILED | View |
OBTAIN PERMIT TO CORRECT ELECTRICAL VIOLATIONS 13-12-360 | 1111 N MONITOR AVE | COMPLAINT | PASSED | View | |
PRV BALLCOCK,VB,OR AIR GAP | SILLCOCK SOUTH ELEVATION | 1111 N MONITOR AVE | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHTS IN 1ST FLOOR BEDROOM AND BATHROOM | 1111 N MONITOR AVE | COMPLAINT | PASSED | View |
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS 13-12-360 | 1111 N MONITOR AVE | COMPLAINT | PASSED | View | |
PROVIDE A WATER MAIN GROUND CONDUIT, CONDUCTOR TO WITHIN 5 FEET OF WATER METER OR VALVE 14E-2-250.68 C1 | 1111 N MONITOR AVE | COMPLAINT | PASSED | View | |
INSTALL GFCI'S | PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTERTOPS, BATHROOM, AND LAUNDRY AREAS | 1111 N MONITOR AVE | COMPLAINT | PASSED | View |
SUPPLEMENTAL GROUND | SUPPLEMENTAL GROUND NOT CONNECTED TO THE GROUND. | 1111 N MONITOR AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT WOODEN PORCH; GUARDRAIL UNDERSIZED (ONLY 37". 42" IS REQUIRED) GUARDRAIL MISSING PICKETS 2X6" JOIST OVERSPANNED, PLATFORM AND STAIRS FLEXING UNDER LIVE-LOAD. | 1111 N MONITOR AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS AND PERMIT REQUIRED FOR FRONT PORCH SYSTEM. | 1111 N MONITOR AVE | COMPLAINT | PASSED | View |
REPAIR ROOF | NORTHWEST AND SOUTHWEST CORNER OF THE ROOF STARTING TO COLLAPSE IN NEED OF REPAIR. | 1111 N MONITOR AVE | COMPLAINT | PASSED | View |
STRAP SERVICE CONDUIT | SUPPORT SERVICE ENTRANCE PIPE ON THE REAR OF THE HOUSE. | 1111 N MONITOR AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR. UNVERIFIED OCCUPANCY. OR LIVING CONDITIONS | 1111 N MONITOR AVE | COMPLAINT | PASSED | View |