The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED ALL YEARS 1990 THROUGH 2015 YEARS . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - POSTED OWNER'S I.D. SIGN , NOT VISIBLE FROM STREET . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
PARAPET | WEST PARAPET SPALLED BRICKS AND OPEN MORTAR JOINTS . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
SERVICE DROP OUT OF REACH | REAR OFF PORCH DECK , INCOMING POWER SERVICE CABLES WITHIN REACH OF TENANTS AND OCCUPANTS . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
RESTORE EXIT AND EM | FRONT ENTRY STAIRWAYS , BACKUP LIGHTS OUT OF SERVICE AT TIME OF INSPECTION . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
DWELLING CLEAN AND SANITARY | FRONT ENTRY STAIRWAYS , DIRTY , UNSANITARY , TRASH , CIGARETTE BUTTS , ODORS | 3417 W NORTH AVE | PERIODIC | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | FRONT ENTRY DOOR AND STAIRWAY DOORS MISSING ALL DEADBOLTS LOCKS , BUILDING NOT SECURE , HAZARD TO TENANTS AND OCCUPANTS . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT ENTRY STAIRWAYS , WORN AND LOOSE TREADS AND HANDRAILS . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
INT WALL/CEILING CHIP PLASTER | FRONT ENTRY STAIRWAYS , BROKEN PLASTER , HOLES , FLAKING PAINT , WALLS DIRTY AND UNSANITARY . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | FRONT ENTRY STAIRWAYS , BROKEN SMOKE DETECTORS . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQUIRED | 3417 W. NORTH - COMMERCIAL UNIT ALTERED TO BANQUET HALL AND KITCHEN FOR RENT . SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED ALTERATIONS OR RESTORE THE BUILDING TO THE ORIGINAL STATE . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED | SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK FOR REAR PARKING LOT TEN FOOT IRON FENCES AND IRON DRIVEWAY GATES . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR THREE STORY WOOD PORCH , CURRENT REPAIRS COMPLETED WITHOUT PLANS AND PERMITS . COLUMNS NOTCHED , BEAMS UNDERSIZED WITH OPEN GAPS AT FIRECUTS . FLOOR JOIST OVERSPANNED AND UNDERSIZED . IRON GUARDRAILS OVERSPANNED . IRON STAIRWAY SUBSTANDARD AND POORLY CONSTRUCTED . MISSING GUARDRAILS AND RISER BOARDS , FALL HAZARD . PLANS AND PERMITS REQUIRED . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | REAR ELEVATION , SPALLED AND LOOSE MASONRY PARGING COATING . REMOVE PARGING COATING AND RESTORE BRICKWORK TO ORIGINAL . MASONRY PERMIT REQUIRED . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | 2 BASEMENTS CEILINGS MISSING DRYWALL FIRE HAZARD | 3417 W NORTH AVE | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | 3419 W NORTH AVE BASEMENT (1ST FLOOR FLOOR JOISTS) CUT NOTCHED AND SUPPORTED WITH 6X6 BEAMS AND COLUMNS SOME AREAS NOT SUPPORTED SOME AREAS HAVE 2X4 DECK JOINTS WEAK UNSTABLE DANGEROUS AND HAZARDOUS PLANS AND PERMIT REQUIRED FOR 1ST FLOOR FLOOR JOIST REPAIRS AND SUPPORTS | 3417 W NORTH AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 3419 W NORTH AVE BASEMENT MISSING CARBON MONOXIDE DETECTOR | 3417 W NORTH AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | FIRE EXTINGUISHER TAGS 2011-OUTDATED DANGEROUS | 3417 W NORTH AVE | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | 3419 W NORTH AVE 1ST FLOOR TENANT COMMERCIAL SPACE EXIT SIGNS NOT ILLUMINATED AND MISSING AT REAR-ELECTRICAL PERMIT REQUIRED FOR EXIT SIGN INSTALLATIONS | 3417 W NORTH AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | STEEL PICKET FENCE AND CHAIN LINK OVER 5' REDUCE HEIGHT, REMOVE, OR OBTAIN A PERMIT 14A-4-401.1 | 3417 W NORTH AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | VARIOUS WINDOWS ARE BOARDED NORTH AND SOUTH 14X-3-303.13 | 3417 W NORTH AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR OF PROPERTY | 3417 W NORTH AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | NEW SET OF STEEL STAIRS/GUARDRAILS CONSTRUCTED WITHOUT PROPER PLANS/PERMITS 14A-4-401.1 | 3417 W NORTH AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | CHAIN LINK FENCE MISSING TOP RAIL 14X-3-302.5-14X-12-1205.5.5 | 3417 W NORTH AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | FRONT ENTRY FOYER , CEILING LIGHT FIXTURE MISSING EXPOSED WIRES . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | FRONT ENTRY DOORS , MARKER GRAFFITI . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
GRADE AND DRAIN LOT | REAR PARKING LOT , NO HARD PAVEMENT , DRAINAGE OR PARKING LOT LANDSCAPE . GRAVEL PARKING LOT RUTS , STANDING WATER . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
REPAIR SKYLIGHT | FRONT ENTRY STAIRWAYS , SKYLIGHTS , CRACKED AND BROKEN GLASS . | 3417 W NORTH AVE | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 3419 W NORTH AVE BASEMENT STAIRWAY GRADE TO BASEMENT MISSING STAIR RAILS FALLING HAZARD DANGEROUS AND HAZARDOUS | 3417 W NORTH AVE | COMPLAINT | FAILED | View |