Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | REFUSED ENTRY / UNVERIFIED DETECTORS AND OCCUPANCY | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | 18-27-110.3 PROVIDE INTERIOR INSPECTION TO VERIFY LOCATION AND CONDITIONS OF ELECTRICAL PANEL AND METER BOX | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | BASEMENT BUILD-OUT, SEE PARTITIONS CREATING BEDROOMS, KITCHEN AREAS, FULL BATHROOM, PLANS AND PERMITS ARE REQUIRED. | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE TO ORIGINAL USE. | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
NO PERMIT WIRING | OBTAIN PERMIT FOR THE ALTERATION OF THE BUILDING ELECTRICAL SYSTEM, NEW SERVICE INSTALLED, AND BASEMENT BUILD OUT DONE. | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
REMOVE************** | REMOVE DRYWALL INSTALLED PRIOR TO ROUGH INSPECTION OF THE BASEMENT 13-12-380 | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
DEFECTIVE DISTRIBUTION | BRANCH CIRCUIT WIRING - USE OF SUBSTANDARD WIRING NOT LISTED FOR USE; CONDUCTORS IN PANEL ARE NOT LISTED WIRE. | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
WORKING SPACE | 3 FEET CLEARANCE FOR ELECTRICAL PANEL IS NOT MET. | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
ADD BRANCH CIRCUITS | BRANCG CIRCUIT WIRING DOES NOT MEET COLOR CODE REQUIREMENTS FOR 18-22-210.8; STOP USE OF GREEN WIRE FOR ENERGIZED CONDUCTOR. | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
PROPER SIZE OCP | STOP USE OF ILLEGAL MINI BREAKERS | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAY | THE CONDUIT SYSTEM IN BASEMENT IS COMPOSED OF FITTINGS AND RODS OF CONDUIT, STEM IS NOT LISTED FOR USE; MISMATCH OF FITTING AND CONDUCTORS; ARMORED CABLE FITTING USED FOR EMT; RIGHT ANGLE 2 PIECE FITTING IS NOT ASSESSABLE. | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
INSTALL COVERS | INSTALL COVER ON JUNCTION BOX IN THE BASEMENT | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
ARMORED CABLE | REMOVE EXPOSED RUNS IN BASEMENT CEILING AND OPEN WALLS | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
SECURE RACEWAY | STRAP AND SECURE RACEWAY AND ARMORED CABLE IN BASEMENT | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
CLOSE BOX OPENINGS | KNOCK OUTS ARE MISSING AND PANEL COVER IS NOT PROPERLY SECURE | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
GROUNDING RECEPTACLES | INSTALL GROUNDING RECEPTACLE OUTLETS ON THE FIRST FLOOR | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
MULTIPLE CONDUCTOR TERM | TWO CONDUCTORS ARE TERMINATED UNDER SINGLE BREAKER IN PANEL | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
ACCESS TO JBS | PROVIDE PERMANENT ACCESS TO CONCEALED JUNCTION BOX IN THE BASEMENT | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | PROVIDE GFCI PROTECTION FOR KITCHEN COUNTERS AND BATHS 18-27-570.8 | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
UNAPPROVED CORDS | UNLISTED WIRING IN PANEL NOT RATED / SUBSTANDARD | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
VENT SYSTEM TO PRVNT BACK PRES | TOILET ROOM IN BASEMENT HAS NO VENTS FOR TOILET, LAVATORY, SHOWER, AND SEWAGE BASIN. | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
PRV FLOOR DRAIN WITH METAL STR | INSTALL FLOOR DRAIN FOR WATER HEATER | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PLUMBING PERMIT TO CORRECT VIOLATIONS | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN LICENSED PLUMBER. | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
EXPOSE FOR INSPECT APPROVAL | EXPOSE PLUMBING SYSTEM FOR INSPECTION IN THE BASEMENT | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
INSTALL TRAP,WASTE,VENT PIPES | INSTALL VENT FOR SERVICE SINK; INSTALL PROPER WASTE, VENT, AND TRAP FOR CLOTHES WASHING MACHINE; REMOVE RUNNING TRAP FOR TUB AND INSTALL PROPER VENT AND TRAP ON FIRST FLOOR. | 4852 S LAMON AVE | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE WATER LINES TO PLUMBING FIXTURES ON FIRST FLOOR AND BASEMENT FLOOR AND WATER HEATER. | 4852 S LAMON AVE | COMPLAINT | PASSED | View |