Chicago Building Violations Data: 27 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION REFUSED ENTRY / UNVERIFIED DETECTORS AND OCCUPANCY 4852 S LAMON AVE COMPLAINT PASSED View
SEE INSPECTOR COMMENTS 18-27-110.3 PROVIDE INTERIOR INSPECTION TO VERIFY LOCATION AND CONDITIONS OF ELECTRICAL PANEL AND METER BOX 4852 S LAMON AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR BASEMENT BUILD-OUT, SEE PARTITIONS CREATING BEDROOMS, KITCHEN AREAS, FULL BATHROOM, PLANS AND PERMITS ARE REQUIRED. 4852 S LAMON AVE COMPLAINT PASSED View
WORK NOT ALLOWED SUBMIT PLANS AND OBTAIN PERMITS FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE TO ORIGINAL USE. 4852 S LAMON AVE COMPLAINT PASSED View
NO PERMIT WIRING OBTAIN PERMIT FOR THE ALTERATION OF THE BUILDING ELECTRICAL SYSTEM, NEW SERVICE INSTALLED, AND BASEMENT BUILD OUT DONE. 4852 S LAMON AVE COMPLAINT PASSED View
REMOVE************** REMOVE DRYWALL INSTALLED PRIOR TO ROUGH INSPECTION OF THE BASEMENT 13-12-380 4852 S LAMON AVE COMPLAINT PASSED View
DEFECTIVE DISTRIBUTION BRANCH CIRCUIT WIRING - USE OF SUBSTANDARD WIRING NOT LISTED FOR USE; CONDUCTORS IN PANEL ARE NOT LISTED WIRE. 4852 S LAMON AVE COMPLAINT PASSED View
WORKING SPACE 3 FEET CLEARANCE FOR ELECTRICAL PANEL IS NOT MET. 4852 S LAMON AVE COMPLAINT PASSED View
ADD BRANCH CIRCUITS BRANCG CIRCUIT WIRING DOES NOT MEET COLOR CODE REQUIREMENTS FOR 18-22-210.8; STOP USE OF GREEN WIRE FOR ENERGIZED CONDUCTOR. 4852 S LAMON AVE COMPLAINT PASSED View
PROPER SIZE OCP STOP USE OF ILLEGAL MINI BREAKERS 4852 S LAMON AVE COMPLAINT PASSED View
CONTINUITY OF RACEWAY THE CONDUIT SYSTEM IN BASEMENT IS COMPOSED OF FITTINGS AND RODS OF CONDUIT, STEM IS NOT LISTED FOR USE; MISMATCH OF FITTING AND CONDUCTORS; ARMORED CABLE FITTING USED FOR EMT; RIGHT ANGLE 2 PIECE FITTING IS NOT ASSESSABLE. 4852 S LAMON AVE COMPLAINT PASSED View
INSTALL COVERS INSTALL COVER ON JUNCTION BOX IN THE BASEMENT 4852 S LAMON AVE COMPLAINT PASSED View
ARMORED CABLE REMOVE EXPOSED RUNS IN BASEMENT CEILING AND OPEN WALLS 4852 S LAMON AVE COMPLAINT PASSED View
SECURE RACEWAY STRAP AND SECURE RACEWAY AND ARMORED CABLE IN BASEMENT 4852 S LAMON AVE COMPLAINT PASSED View
CLOSE BOX OPENINGS KNOCK OUTS ARE MISSING AND PANEL COVER IS NOT PROPERLY SECURE 4852 S LAMON AVE COMPLAINT PASSED View
GROUNDING RECEPTACLES INSTALL GROUNDING RECEPTACLE OUTLETS ON THE FIRST FLOOR 4852 S LAMON AVE COMPLAINT PASSED View
MULTIPLE CONDUCTOR TERM TWO CONDUCTORS ARE TERMINATED UNDER SINGLE BREAKER IN PANEL 4852 S LAMON AVE COMPLAINT PASSED View
ACCESS TO JBS PROVIDE PERMANENT ACCESS TO CONCEALED JUNCTION BOX IN THE BASEMENT 4852 S LAMON AVE COMPLAINT PASSED View
SEE INSPECTOR COMMENTS PROVIDE GFCI PROTECTION FOR KITCHEN COUNTERS AND BATHS 18-27-570.8 4852 S LAMON AVE COMPLAINT PASSED View
UNAPPROVED CORDS UNLISTED WIRING IN PANEL NOT RATED / SUBSTANDARD 4852 S LAMON AVE COMPLAINT PASSED View
VENT SYSTEM TO PRVNT BACK PRES TOILET ROOM IN BASEMENT HAS NO VENTS FOR TOILET, LAVATORY, SHOWER, AND SEWAGE BASIN. 4852 S LAMON AVE COMPLAINT PASSED View
PRV FLOOR DRAIN WITH METAL STR INSTALL FLOOR DRAIN FOR WATER HEATER 4852 S LAMON AVE COMPLAINT PASSED View
OBTN PERMIT FOR PLUMBING WORK OBTAIN PLUMBING PERMIT TO CORRECT VIOLATIONS 4852 S LAMON AVE COMPLAINT PASSED View
LICENSED BONDED PLMBG CONTRCTR OBTAIN LICENSED PLUMBER. 4852 S LAMON AVE COMPLAINT PASSED View
EXPOSE FOR INSPECT APPROVAL EXPOSE PLUMBING SYSTEM FOR INSPECTION IN THE BASEMENT 4852 S LAMON AVE COMPLAINT PASSED View
INSTALL TRAP,WASTE,VENT PIPES INSTALL VENT FOR SERVICE SINK; INSTALL PROPER WASTE, VENT, AND TRAP FOR CLOTHES WASHING MACHINE; REMOVE RUNNING TRAP FOR TUB AND INSTALL PROPER VENT AND TRAP ON FIRST FLOOR. 4852 S LAMON AVE COMPLAINT PASSED View
PROPER MATRL WATER SUPPLY PIPE REMOVE FLEXIBLE WATER LINES TO PLUMBING FIXTURES ON FIRST FLOOR AND BASEMENT FLOOR AND WATER HEATER. 4852 S LAMON AVE COMPLAINT PASSED View