The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
RMV PLBFIX INSTALLD W/0 PERMIT | IN BASEMENT AND UNDERGROUND IN AND OUTSIDE | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
RMV WATER,SOIL,WASTE,VENT | IN BASEMENT AND UNDERGROUND IN AND OUT | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
SUBMIT PLANS FOR PLUMBING PRMT | 8333 S BURLEY AVE | COMPLAINT | FAILED | View | |
STOP/REMOVE NUISANCE | EAST YARD - ABANDONED VEHICLE. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT STAIRWAY - GRADE TO 1ST - LEDGER BEAM ONLY NAILED TO BUILDING . BEAMS ONLY NAILED TO COLUMNS. STRINGERS ONLY NAILED TO HEADER JOISTS. GUARDRAILS ONLY 37'' HIGH WITH MISSING PICKETS. HANDRAILS - LOOSE. REAR BASEMENT STAIRWAY - GRADE TO BASEMENT - BROKEN AND MISSING CONCRETE SECTIONS , HANDRAIL - MISSING. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST PORCH - COLUMNS ERECTED ON CONCRETE BASES - FOUNDATION STATUS UNKNOWN. BEAMS ONLY NAILED TO COLUMNS. STRINGERS ONLY NAILED TO HEADER JOISTS. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | SOUTHWEST DOWNSPOUT - MISSING. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | EAST AND WEST YARDS - HIGH WEEDS. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2005 THROUGH 2011. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EAST BASEMENT STAIRWAY - GRADE TO BASEMENT - GUARDRAILS - MISSING. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | EAST BASEMENT DOOR - BROKEN - BOTTOM 3' SECTION COVERED WITH 1/2'' CEMENT BOARD. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | EAST - 6' WOOD FENCE - BROKEN AND MISSING SECTIONS. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | EAST EAVES - METAL FASCIA COVER - MISSING. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | EAST UNDER PORCH - GARBAGE AND DEBRIS. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
ILLUMINATE EXIT AREAS | WEST STAIRWAY AT GRADE TO 1ST - MISSING ILLUMINATION. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT 2 STORY OPEN WOOD AND STEEL PORCH - COLUMNS ERECTED ON CONCRETE BASES - FOUNDATION STATUS UNKNOWN. AT 2ND - 2 X 8 DECK JOISTS DOUBLED AND BOTH SECTIONS OF DECK JOISTS NOT SPANNING FULL DISTANCE - BROKEN AND SPLICED- NOT PROPERLY SUPPORTED - SPLICED BOARDS ONLY NAILED TOGETHER. WOODEN STRINGERS AT 2ND ONLY NAILED TO HEADER AND RIM JOISTS. 2ND LEVEL TOP DECKS SHIFTING AND UNSTABLE. STAIR RISERS VARY 8'' TO 10''. METAL AND WOOD GUARD AND HANDRAILS LOOSE WITH GUARDRAIL SECTIONS AT 32'' TO 38'' HIGH - PICKETS SPACED 5'' APART. PLANS AND PERMIT REQUIRED FOR FRONT PORCH REPAIRS. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
CHIMNEY HEIGHT | SOUTHEAST METAL FLUE PIPE ONLY 1' ABOVE ROOF AT GUTTER AND ONLY 4'' TO 6'' AWAY FROM ROOF [ GABLE ROOF ] . FLUE GAS HAZARD. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | SOUTH AT 2ND - NEW WINDOW INSTALLED 15'' X 36'' SMALLER THAN ORIGINAL WINDOW - PERMIT REQUIRED FOR INSTALLATION OF MUCH SMALLER WINDOW. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | EAST , NORTHEAST , AND SOUTHEAST EAVES - SOFFIT SECTIONS -MISSING. WEST GABLE EAVES - ROTTED WITH PEELING PAINT. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | NORTHEAST AND SOUTHEAST ROOF SECTIONS - BUCKLED. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | EAST AND WEST METAL GATES WITH DOUBLE KEY LOCKS - HAMPERING EGRESS. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST AND WEST BASEMENT STAIRWAYS - GRADE TO BASEMENT - HANDRAILS - MISSING. SOUTH STAIRWAY - GRADE TO 1ST - COLUMNS ERECTED ON SOIL AND CONCRETE BASES - FOUNDATION STATUS UNKNOWN. BEAMS ONLY NAILED TO COLUMNS. STRINGERS ONLY NAILED TO COLUMNS AND HEADER JOISTS. TREADS SPLIT AND ROTTED. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EAST AND WEST BASEMENT STAIRWAYS - GRADE TO BASEMENT AT GRADE GUARDRAILS - MISSING. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS OR VERIFY COMPLAINTS OF BUGS AND NO HEAT. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2005 THROUGH 2011. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | WINDOW SCREENS TORN | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EXTERIOR FRONT 2 STORY PORCH SYSTEM OF WOOD AND STEEL: COLUMNS UNKNOWN; JOIST 2X8 DOUBLED/ SCABBED EITHER JOIST NOT SPANNING FULL DISTANCE OF SPAN; STAIR STRINGER WOOD NOT STABLE, NAILED CONNECTIONS, SHIFTING, UNEVEN RISER HEIGHTS STAIR RISERS VARY FROM 8-10" ; LEDGER/ HEADER ALL NAILED CONNECTION; GUARDRAILS DEFLECT UNDER LOAD EXCESSIVE SPACING AT PICKETS, WITH HEIGHTS 32"- 38". PROVIDE PLANS AND PERMIT. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOWS WEST BASEMENT AND 1ST FLOOR FRONT BROKEN. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | EXTERIOR NORTHEAST AND SOUTH EAST SECTIONS BUCKLED. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | EXTERIOR EAST, NORTHEAST , AND SOUTH SOFFIT ROTTED WITH HOLES. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EXTERIOR SOUTH SIDE STAIRS: HANDRAILS LOOSE AND DEFLECT UNDER LAOD; LANDING UNSTABLE; ROTTED STAIRS; FOUNDATION NOT VERFIED; PERMIT REQUIRED. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | EXTERIOR FRONT, REAR, AND SIDE GATES DOUBLE KEY LOCKS. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOWS NORTH, SOUTH, AND WEST ELEVATIONS ROTTED WITH PEELING PAINT. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
CHIMNEY HEIGHT | EXTERIOR SOUTH CHIMNEY METAL FLUTE PIPE ONLY 1' ABOVE ROOF AND 4-6" AWAY FROM ROOF. (GABLE ROOF) | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING PEELING PAINT | 1REAR BATHROOM EVIDENCE OF WATER DAMAGE WALLS AND CEILING. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | 1REAR BEDROOMS NO WORKING OUTLETS. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
RAT PROOF OPENINGS | INTERIOR 1REAR OPENINGS AROUND PIPES. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
KEEP FIXTUR CLEAN AND SANITARY | 1 REAR KITCHEN SINK CABINET UNSANITARY. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | IRON GATES KEYLOCKS | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOW FRAMES ROTTED | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WINDOW SASHES NOT SET PROPERLY IN FRAMES AND ROTTED | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
PROVIDE | GUTTERS AND DOWNSPOUTS MISSING (SEC 13-196-600) | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | EAVES ROTTED | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | POST ADDRESS | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | SOUTH PORCH PICKETS MISSING, RAILS LOOSE, TREADS WOOD SPLIT, NO FOOTING, NO RISER, REPLACE 4X4 WITH 6X6, ROOF ROTTED AND BROKEN, WEST PORCH REPLACE 4X4 WITH 6X6, 4X4 WOOD SPLIT AND OVERCUT, 1ST RISER IMPROPER HEIGHT, SUBMIT PLANS AND PERMITS FOR REPAIRS | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EAST AND WEST BASEMENT STAIR NO GUARDRAILS | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION WINDOW PANES BROKEN, BASEMENT WINDOW BOARDED UP | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOW SCREENS MISSING | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMITS PLANS AND PERMITS FOR NEW GARAGE NEW ENCLOSE PORCH ADDITION, WEST BASEMENT STAIR AND INSTALLING DOOR OPENING IN FOUNDATION | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | FOUNDATION AT GRADE MORTAR MISSING WEST WALL AROUND DOOR LOOSE BRICKS | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTER | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST AT 1ST - WINDOW - BROKEN PANE. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | NORTH , SOUTH , AND WEST WINDOW FRAMES - ROTTED WITH PEELING PAINT. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | PROVIDE EVIDENCE OF BUILDING REGISTRATION FOR YEARS 1990-2012. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | 1 REAR FURANACE WIRES EXSPOSED. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
ROACHES | 1REAR ROACHES. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EXTERIOR FRONT GRADE TO BASEMENT MISSING HAND AND GUARDRAILS. | 8333 S BURLEY AVE | COMPLAINT | FAILED | View |