Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-26 @ 1:38 AM
PIN: 13342030410000
Property Address: 4201 W FULLERTON AVE
City - Zip: CHICAGO - 60639
2023 Property Class: 212
2023 Township: 71 - Jefferson
2023 Neighborhood: 71180
2023 Tax District: 71167
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 43 Violations
Violation Inspector Comments Address Category Status View
PROVIDE BASEMENT CEILING HAS A COMPLETE LACK OF FIRE SEPARATION TO COMMERCIAL SPACE ABOVE, EXPOSED FLOOR JOISTS. 6(13-60-200) 4201 W FULLERTON AVE COMPLAINT PASSED View
PROVIDE BASEMENT CEILING HAS A COMPLETE LACK OF FIRE SEPARATION TO COMMERCIAL SPACE ABOVE, EXPOSED FLOOR JOISTS. 6(13-60-200) DANGEROUS CONDITION. 4201 W FULLERTON AVE COMPLAINT FAILED View
PROVIDE PROVIDE TEMPERING VALVE FOR LAVATORY MENS AND WOMENS WASHROOM 1ST FLOOR. (18-29-607.1.1) 4201 W FULLERTON AVE COMPLAINT PASSED View
LICENSED BONDED PLMBG CONTRCTR OBTAIN LICENSED PLUMBER TO PERFORM ALL PLUMBING WORK. 4201 W FULLERTON AVE COMPLAINT PASSED View
RESTORE EXIT AND EM EXIT SIGN DAMAGED WEST WALL OF TAVERN, MISSING SYSTEM III BATTERY BACK-UP EXIT SIGN AT FRONT DOOR EXIT, BATTERY PACKS THROUGHOUT NOT FUNCTIONING - DANGEROUS CONDITION. 4201 W FULLERTON AVE COMPLAINT PASSED View
BOX UNUSED OPENINGS MISSING K.O. FILLERS THROUGHOUT BASEMENT AND ON ELECTRICAL BOX FOR THE BOILER - DANGEROUS CONDITION. 4201 W FULLERTON AVE COMPLAINT PASSED View
UNAPPROVED CORDS EXTENSION CORDS GOING INTO DROP CEILING, EXTENSION CORDS GOING THROUGH FLOOR - DANGEROUS CONDITION. 4201 W FULLERTON AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION NO ENTRY TO 2ND FLOOR UNITS. 4201 W FULLERTON AVE COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# MISSING OWNER POSTING. 4201 W FULLERTON AVE COMPLAINT PASSED View
OBSTRUCTIONS IN EXIT WAY EAST MARKED EXIT DOOR AT 32". (13-160-220) DANGEROUS CONDITION REQUIRES PERMIT TO REMEDIATE. 4201 W FULLERTON AVE COMPLAINT PASSED View
PROVIDE BREACH IN FIRE SEPARATION ABOVE DROP CEILING FROM COMMERCIAL SPACE TO RESIDENTIAL ABOVE BROKEN PLASTER WITH EXPOSED LATH. (13-56-280) DANGEROUS CONDITION. 4201 W FULLERTON AVE COMPLAINT PASSED View
INTERIOR FINISH FIRERESISTANCE COMMERCIAL SPACE HAS WOOD PANELING, LACKING FIRE SPREAD RATING. (15-8-370, 15-12-340) DANGEROUS CONDITION. 4201 W FULLERTON AVE COMPLAINT PASSED View
DWELLING CLEAN AND SANITARY WOMENS BATHROOM CEILING HAS BLACK MOLD. 4201 W FULLERTON AVE COMPLAINT PASSED View
FIRE EXTNGSHR RECHARGE & TAG FIRE EXTINGUISHER HAS EXPIRED TAGS - DANGEROUS CONDITION. 4201 W FULLERTON AVE COMPLAINT PASSED View
PARAPET EAST PARAPET BOWED INWARD OVER PUBLIC WALK. 4201 W FULLERTON AVE COMPLAINT PASSED View
REPAIR EXTERIOR WALL EAST WALL HAS STRESS CRACKS 1ST THRU 2ND FLOOR. 4201 W FULLERTON AVE COMPLAINT PASSED View
PROTECT SIDEWALK DURING CONST PROVIDE A CANOPY AT EAST ELEVATION FOR PARAPET OVER PUBLIC WALK - DANGEROUS CONDITION. 4201 W FULLERTON AVE COMPLAINT PASSED View
PARAPET & COPING EAST PARAPET HAS BROKEN/MISSING COPING. 4201 W FULLERTON AVE COMPLAINT PASSED View
PERMIT REQUIRED - CONTRACTOR EAST ELEVATION HAS WINDOWS THAT HAVE BEEN INFILLED WITH BRICK. ALL WORK CONSTRUCTED WITHOUT PROPER MASON'S PERMIT. 4201 W FULLERTON AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR REPAIRS TO EAST WALL/PARAPET WILL REQUIRE PROPER PLANS AND OR PERMITS. 4201 W FULLERTON AVE COMPLAINT PASSED View
PROPER MATRL WATER SUPPLY PIPE REMOVE FLEXIBLE SUPPLY LINE AT LAVATORY, TOILET 1ST FLOOR THROUGHOUT PREMISE. 4201 W FULLERTON AVE COMPLAINT PASSED View
PROVIDE OPEN FRONT TOILET SEAT PROVIDE OPEN FRONT COMMERCIAL TOILET SEAT FOR MENS AND WOMEN WASHROOM 1ST FLOOR. 4201 W FULLERTON AVE COMPLAINT PASSED View
SOIL/WASTE,VENT PIPE MATRL REMOVE ALL 4" PVC UNDERGROUND PIPING IN BASEMENT, ALL LOCATIONS. REMOVE 4" PVC SUSPENDED WASTE PIPE IN BASEMENT WEST AND NORTH ELEVATION. REMOVE ALL 2" PVC DRAIN PIPING IN BASEMENT, ALL LOCATIONS. 4201 W FULLERTON AVE COMPLAINT PASSED View
REMOVE REMOVE ALL 2" AND 4" FERNCO FITTINGS THROUGHOUT BASEMENT. (18-29-705.1.4) 4201 W FULLERTON AVE COMPLAINT PASSED View
SOIL/WASTE,VENT PIPE MATRL REMOVE ALL 1 1/2" AND 2" PVC IN BASEMENT THROUGHOUT ALL ELEVATIONS. 4201 W FULLERTON AVE COMPLAINT PASSED View
PROVIDE PROVIDE DIELECTRIC UNIONS IN BASEMENT ALL ELEVATIONS AND THROUGHOUT. (18-29-605.2.1.1) 4201 W FULLERTON AVE COMPLAINT PASSED View
KEEP FIXTUR CLEAN AND SANITARY KEEP ALL FIXTURE IN CLEAN CONDITION 1ST FLOOR AND BASEMENT ALL ELEVATIONS. 4201 W FULLERTON AVE COMPLAINT PASSED View
SOIL/WASTE,VENT PIPE MATRL REMOVE 2" PVC DISCHARGE PIPE AT PIT NORTH ELEVATION. 4201 W FULLERTON AVE COMPLAINT PASSED View
PROVIDE PROVIDE PROPER AND APPROVED PIPE SUPPORT FOR 4" AND 2" HORIZONTAL PIPING, ALL ELEVATIONS IN BASEMENT. (18-29-308.5, 18-29-308.4, 18-29-308) 4201 W FULLERTON AVE COMPLAINT PASSED View
OBTN PERMIT FOR PLUMBING WORK OBTAIN PERMIT FOR ALL VIOLATIONS. 4201 W FULLERTON AVE COMPLAINT PASSED View
DEFECTIVE FIXTURES MISSING COVER ON LIGHT FIXTURE IN LADIES ROOM OF TAVERN. 4201 W FULLERTON AVE COMPLAINT PASSED View
REMOVE OLD ABANDONED RACEWAYS IN BASEMENT, REMOVE OLD ABANDONED RACEWAYS FROM EXTERIOR OF BUILDING ON EAST ELEVATION. (18-27-110.12(E)) 4201 W FULLERTON AVE COMPLAINT PASSED View
SPLICE IN CORD SPLICE IN EXTENSION CORD IN BASEMENT PLUGGED INTO RECEPTACLE GOING THROUGH FLOOR - DANGEROUS CONDITION. 4201 W FULLERTON AVE COMPLAINT PASSED View
INSTALL COVERS MISSING COVER ON TAVERN PANEL - DANGEROUS CONDITION. 4201 W FULLERTON AVE COMPLAINT PASSED View
INSTALL ILLUMINATION MISSING LIGHTS AT EXTERIOR OF ENTRANCES. 4201 W FULLERTON AVE COMPLAINT PASSED View
WORKING SPACE TAVERN PANEL BEHIND DOOR IN BASEMENT AREA - DANGEROUS CONDITION, INACCESSIBLE. 4201 W FULLERTON AVE COMPLAINT PASSED View
LIVE FRONT SWITCHBOARD LIVE FRONT DISCONNECT IN BASEMENT AT STAIRS - DANGEROUS CONDITION. 4201 W FULLERTON AVE COMPLAINT PASSED View
STOP LEAKING WATER WATER LEAK IN WOMENS WASHROOM CEILING 1ST FLOOR. 4201 W FULLERTON AVE COMPLAINT PASSED View
SOIL/WASTE,VENT PIPE MATRL REMOVE 1 1/2" PVC WASTE PIPE AT BAR SINK AND MENS WASHROOM 1ST FLOOR. 4201 W FULLERTON AVE COMPLAINT PASSED View
COVER OUTLETS AND JBS OPEN BOXES THROUGHOUT ENTIRE TAVERN AREA AND BASEMENT OF TAVERN - DANGEROUS CONDITION. 4201 W FULLERTON AVE COMPLAINT PASSED View
REMOVE REMOVE 1 1/2" FERNCO AT BAR SINK 1ST FLOOR AND BASEMENT WEST ELEVATIONS AND THROUGHOUT PREMISE. (18-29-705.1.4) 4201 W FULLERTON AVE COMPLAINT PASSED View
NEED ALL DROP CEILINGS REMOVED TO VERIFY WIRING FOR LIGHTS IN TAVERN AREA. (13-12-380) 4201 W FULLERTON AVE COMPLAINT PASSED View