Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
INSTALL EXIT SIGN | INTERIOR- EXIT SIGN MISSING AT REAR. | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | (SR#07-01822796) NORTH ELEVATION-DRIVEWAY, AREAWAY ARE CRACKED WEST ELEVATION ALSO. | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION- PEELING PAINT ON EXTERIOR WALL. SOUTH ELEVATION- OPEN JOINTS IN EXTERIOR WALL @ WINDOW. | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR FENCE | EAST ELEVATION- GATE IS MISSING TOP RAIL; LEANING, UNSECURED. SOUTH ELEVATION-CHAIN LINE FENCE HAD CUT-HUGE OPENING. | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | SOUTH ELEVATION-ELECTRICAL POLE (6X6) ATTACHED TO EXTERIOR WALL IS ROTTING (SEC. 7-28-060) | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | SOUTH ELEVATION- ONE DOWNSPOUT IS MISSING ANOTHER IS RUSTING. | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION- WINDOW PANE IS MISSING. | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR LINTELS | WEST ELEVATION- LINTEL AT OVERHEAD IS RUSTING | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | INTERIOR-REAR-BEVERAGES, CRATES BLOCKING EXIT. | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR FENCE | WEST ELEVATION CHAIN LINK FENCE MISSING BOTTOM RAILS, LOOSE MECH, NORTH ROLLING GATE IS OFF ITS ROLLERS- DOES NOT OPEN. | 5035 W DIVISION ST | COMPLAINT | CLOSED | View |
REPAIR DOWNSPOUT | WEST DOWNSPOUT IS NOT CONNECTED TO THE DRAIN. | 5035 W DIVISION ST | COMPLAINT | CLOSED | View |
REPAIR OR REPLACE | CONCRETE PAVEMENT THROUGHOUT THE FILLING STATION AREA IS BROKEN WITH MISSING PIECES CREATING DEEP POT HOLES; ELECTRICAL VAULT AT EAST CURB CUT HAS SUNKEN DEEP INTO THE CONCRETE. | 5035 W DIVISION ST | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | BUILDING MISSING SMOKE DETECTORS. | 5035 W DIVISION ST | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | NORTH AND WEST DOORS ARE BLOCKED BY EXCESSIVE STORAGE OF MERCHANDISE AND STORED FUEL PUMPS. | 5035 W DIVISION ST | COMPLAINT | CLOSED | View |
REMOVE | WEST ELEVATION ALONG THE SIDE OF THE BUILDING 4 NON FUNCTIONING GAS FILLING PUMPS ARE STORED (7-28-060) | 5035 W DIVISION ST | COMPLAINT | CLOSED | View |
REPAIR FENCE | FENCE - TOP RAIL BENT; LEANING | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR PLATFORM | CONCRETE PAVEMENT, DRIVEWAY AROUND FILLING STATION - BROKEN, CRACKED CONCRETE, UNEVEN SURFACE, TRIP HAZARDS; DEEP POT HOLES. | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR EXIT - BLOCKED BY CRATES AND BOXES OF FOOD & BEVERAGE | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | HIGH WEEDS AROUND BUILDING | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL - PEELING PAINT. | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | FOR INTERIOR ALTERATIONS OF EXISTING GAS STATION BUILDING INCLUDING BUT NOT LIMITED TO:1.RECONFIGURED PARTITIONS FOR A NEW FOOD MART.2.ELECTRICAL,PLUMBING AND HVAC WORK. | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON THE PREMISES UNTIL A BUILDING PERMIT HAS BEEN OBTAINED (13-12-080)(13-32-035). | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | FOR INTERIOR ALTERATIONS OF EXISTING GAS STATION BUILDING INCLUDING BUT NOT LIMITED TO:1.RECONFIGURED PARTITIONS FOR A NEW FOOD MART.2.ELECTRICAL,PLUMBING AND HVAC WORK.SEE PERMIT #100450759 ISSUED 12-18-12 - STOP ORDER FEES PAID | 5035 W DIVISION ST | COMPLAINT | CLOSED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON THE PREMISES UNTIL A BUILDING PERMIT HAS BEEN OBTAINED (13-12-080)(13-32-035).SEE PERMIT #100450759 ISSUED 12-18-12 - STOP ORDER FEES PAID | 5035 W DIVISION ST | COMPLAINT | CLOSED | View |
ARRANGE PERMIT INSP. | 5035 W DIVISION ST | PERMIT | FAILED | View | |
DWELLING CLEAN AND SANITARY | THE EXTERIOR FLOORS AND WALLS OF THIS GAS STATION ARE FILTHY WITH GROUND DIN DIRT ON THE THE FLOORS THE EXTERIOR CONCRETE LOT IS GRIMY WITH OIL AND CHEMICAL SPILLAGE MIXING WITH THE DIRT BLOWING ACROSS THE LOT FILTHY CONDITION | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | OVERSTOCKING OF GOODS/ MERCHANDISE REDUCING PATH TO REAR EGRESS | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | THE BUILDING HAS NO SMOKE DETECTORS | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | MISSING FLOOR TILE. TRIP HAZARD | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | MISSING FLOOR TILE. TRIP HAZARD | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
FLAKY INTERIOR PAINT | THERE ARE SEVERAL EXTERIOR PAINTED SURFACES WHERE THE PAINT IS CHIPPING/PEELING | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR FENCE | THE PERIMETER WOOD FENCE IS IN POOR CONDITION THE FENCE DEFLECTS UNDER LOAD WITH A SECTION THAT HAS FALLEN | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | THE CONCRETE LOT AREA HAS NUMEROUS SECTIONS WHERE THE CONCRETE HAS SETTLED BELOW GRADE THERE ARE SEVERAL AREA AT/NEAR THE GAS PUMPS WHERE A TRIP HAZARD EXISTS | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | THERE IS A PERIMETER WOOD FENCE OVER 5' IN HEIGHT WITH NO PERMIT ON FILE | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | THE REAR STORAGE AREA HAS AN ELEVATED STORAGE SHELF THAT IS POORLY CONSTRUCTED WITH NAIL WOOD ELEMENTS PULLING APART THIS HEAVILY LADEN SHELF IS POORLY FASTENED TO THE INTERIOR WALLS AS WELL DANGEROUS AND HAZARDOUS | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
FIRE EXTNGSHR RECHARGE & TAG | THE FIRE EXTINGUISHER TAG IS EXPIRED | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | THE EXTERIOR LOT AT ALL ELEVATIONS HAS A LARGE AMOUNT OF GARBAGE/JUNK/DEBRIS LITERED ABOUT THE GENERAL CONDITION OF THE PROPERTY'S EXTERIOR IS UNKEMPT/FILTHY THERE IS ALSO EXCESSIVE GARBAGE ACCUMULATED IN THE INTERIOR OF GAS STATION ESPECIALLY IN THE STORAGE AREA | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
UNINTERRUPTED EXIT AT GRADE | THE REAR EXIT DOOR FROM THE EXTERIOR IS PADLOCKED CLOSED DANGEROUS AND HAZARDOUS | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | NORTH, EAST, SOUTH ELEVATIONS-HIGH WEEDS. | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | DOWNSPOUT - RUSTING; PLASTIC BOTTLE STICKING OUT OF SCUPPER. | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
ARRANGE FOR INSPECTION | CALL 312-743-3562 ASK FOR INSPECTOR #653 RICH HASTINGS ,WEDNESDAYS BETWEEN 8:00 AND 9:00 AM. | 5035 W DIVISION ST | PERIODIC | FAILED | View |
ACCESS TO ROOF | ROOF | 5035 W DIVISION ST | PERIODIC | FAILED | View |
REPAIR**************** | D&H COOLER CAN NOT HAVE SET SCREWS JAKE CONNECTOR OR COUPLINGS MUST BE COMPRESSION FITTINGS ONLY | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR FENCE | WOODEN GATE AT EXTERIOR GARBAGE AREA NOT PROPERLY SUPPPORTED AT HINGE SIDE AND IS DRAGGING ON FLOOR | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | DEFECTIVE FIXTURES IN COOLER, GLOBE LIGHTS NOT WORKING | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
WORKING SPACE | D&H PROVIDE 3' WORKING SPACE FROM ELECTRICAL PANEL | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
RESTORE EXIT AND EM | D&H RESTORE EXIT AND EMERGENCY LIGHTING SYSTEM AND RELATED EQUIPMENT TO WORKING CONDITION | 5035 W DIVISION ST | COMPLAINT | FAILED | View |
REPAIR**************** | IN REAR STORAGE AREA LIGHTS MUST HAVE GLOBE | 5035 W DIVISION ST | COMPLAINT | FAILED | View |