Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 9:42 PM
PIN: 20093290250000
Property Address: 652 W GARFIELD BLVD
City - Zip: CHICAGO - 60609
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72092
2023 Tax District: 72102
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 29 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM NORTH PORCH HAS UNDERSIZED 6X6 BEAMS AND 2X6 JOISTS FOR 7'9" AND 9'10" SPAN. GUARDRAILS ARE 37" POST TO WALL SECURED WITH NAILS. GUARDRAILS DEFLECT UNDER PRESSURE. STRINGER TO 4X4 POSTS AND COLUMNS SECURED WITH NAILSS - JOINTS MISSING HANGERS COLUMN SPLICE CONNECTION IS APPROX 12" AND SECURED WITH NAILS - COLUMN BEAM CONNECTION MISSING STEEL ANGLES - COLUMNS NO FOUNDATION. PROVIDE PLAN AND PERMIT TO REPAIR OR REPLACE 652 W GARFIELD BLVD PERIODIC FAILED View
DEBRIS, EXCESSIVE UNDER REAR PORCH - REFUSE ACCUMULATION 652 W GARFIELD BLVD PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR NO ENTRY TO VERIFY OCCUPANCY - SMOKE AND CARBON MONOXIDE DETECTORS 652 W GARFIELD BLVD PERIODIC FAILED View
NO POSTED ADDRESS BUILDING MISSING OWNERS ID WITH NAME, ADDRESS, PHONE 652 W GARFIELD BLVD PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NEVER REGISTERED 652 W GARFIELD BLVD PERIODIC FAILED View
REPAIR EXTERIOR WALL FRONT ELEVATION WEST ELEVATION WASHED OUT MORTAR FRACTURED JOINTS 652 W GARFIELD BLVD COMPLAINT FAILED View
MAINTAIN PROJECTIONS FRONT ELEVATION ORNAMENTAL LIMESTONE OPEN MORTAR JOINTS 652 W GARFIELD BLVD COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE 1ST FLOOR WEST ELEVATION LARGE GAPS IN REPLACEMENT WINDOWS 652 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH-GRADE TO 3RD IMPROPER FOOTINGS IMPROPER SPLICING OF COLUMNS IMPROPER STRINGER CONNECTIONS JOISTS TOO SMALL FOR SPAN JOINTS ON MID-LANDINGS HAVE NO JOIST HANGERS-TREADS TO NARROW, IMPROPER BEAM TOO COLUMN CONNECTIONS BEAMS NOT PROPERLY ANCHORED INTO BEAM PICKETS ROTTED MIDDLE COLUMN FROM 3RD TO ROOF ROTTED CEILING OF ROOF OF 3RD FLOOR RAILINGS TOO LOW 652 W GARFIELD BLVD COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR OBTAIN PLANS AND PERMITS FOR ALL REPAIRS TO REAR PORCH 652 W GARFIELD BLVD COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR BASEMENT AND 1ST FLOOR REAR REMOVE BURGLAR GATES 652 W GARFIELD BLVD COMPLAINT FAILED View
ILLUMINATE EXIT AREAS REAR PORCH NO LIGHTS 652 W GARFIELD BLVD COMPLAINT FAILED View
RATS REAR YARD-RAT HOLES 652 W GARFIELD BLVD COMPLAINT FAILED View
DEBRIS, EXCESSIVE REAR YARD AND BASEMENT STAIRWELL JUNK AND DEBRIS 652 W GARFIELD BLVD COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# POST ID 652 W GARFIELD BLVD COMPLAINT FAILED View
FILE BLDG REGISTRATION REGISTERED BUILDING 652 W GARFIELD BLVD COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO INTERIOR 652 W GARFIELD BLVD COMPLAINT FAILED View
CHIMNEY CHIMNEY LOOSE BRICKS AND WASHOUT MORTAR 652 W GARFIELD BLVD COMPLAINT FAILED View
CHIMNEY CAPPING CHIMNEY CAP LOOSE AND WASHED OUT MORTAR 652 W GARFIELD BLVD COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR ERECTED NEW 6FT WROUGHT IRON FENCES AT ME NORTH, SOUTH, EAST, + WEST PROPERTY LINES. 652 W GARFIELD BLVD COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR RE-BUILDING EXISTING 8FT X 20FT 3-STORY FRAME OPEN REAR PORCH AT NORTH ELEVATION. 652 W GARFIELD BLVD COMPLAINT FAILED View
BLANK-TEXT MUST CITE CODE SECT STOP WORK ON PREMISES UNTIL A BUILDING PERMIT IS OBTAINED (13-12-080) (13-32-035) 652 W GARFIELD BLVD COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S I.D. SIGN POSTED. 652 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR WINDOW SILLS FRONT ELEVATION/ WINDOW SILLS - WASHED OUT MORTAR. 652 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR CORNICE FRONT ELEVATION/ ORNAMENTAL CORNICE ABOVE 3RD FLOOR WINDOWS - WASHED OUT MORTAR. 652 W GARFIELD BLVD COMPLAINT FAILED View
PARAPET WEST ELEVATION/ PARAPET WALL - SPALLING BRICKS WITH WASHED OUT MORTAR. 652 W GARFIELD BLVD COMPLAINT FAILED View
REPLACE D&H PORCH REAR 3-STORY WOOD PORCH/ COLUMNS ARE RESTING ON BRICKS AND SMALL CONCRETE BLOCKS, COLUMNS ARE SHIFTING OFF THESE BLOCKS. COLUMNS ARE DOUBLE NOTCHED FOR FIRE CUTS AND HEADER NOTCHES; COLUMN ARE WEAK WITH FIRE CUTS AND HEADER NOTCHES AT SAME LOCATION. COLUMN HALF LAP SPLICES ARE ONLY 12 INCHES IN LENGTH AND FASTENED WITH NAILS ONLY. LANDING COLUMNS ARE DOUBLE NOTCHED FOR RIM JOISTS. BEAMS ARE PULLING OUT OF FIRE CUTS AND ARE ONLY NAILED TO TO COLUMNS; OPEN WALL POCKETS WITH MISSING MORTAR. UNDERSIZE 2X6 DECK JOISTS SPAN 10 TO 11 FEET. LANDING RIM JOISTS ARE ONLY NAILED TO COLUMNS. LANDING DECK JOISTS ARE ONLY NAILED TO RIM JOISTS. STRINGERS - UPPER END ARE INADEQUATELY SUPPORTED WITH NAILS ONLY. ENTIRE LANDING IS WEAK AND UNSTABLE; SWAYS EXCESSIVELY. ALL RAIILING ARE LOOSE, PULLING AND ONLY NAILED TO COLUMNS AND POSTS. GUARD RAILINGS ARE ONLY 37 INCHES HIGH. STAIR TREADS ARE LOOSE. PLANS AND PERMIT ARE REQUIRED TO REPLACE REAR PORCH. 652 W GARFIELD BLVD COMPLAINT FAILED View
PARAPET & COPING WEST ELEVATION WASHED OUT MORTAR AND MISSING COPING TILE AT BACK 652 W GARFIELD BLVD COMPLAINT FAILED View
REPAIR FENCE EAST ELEVATION REAR YARD REPAIR FENCE 652 W GARFIELD BLVD COMPLAINT FAILED View