The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | NORTH PORCH HAS UNDERSIZED 6X6 BEAMS AND 2X6 JOISTS FOR 7'9" AND 9'10" SPAN. GUARDRAILS ARE 37" POST TO WALL SECURED WITH NAILS. GUARDRAILS DEFLECT UNDER PRESSURE. STRINGER TO 4X4 POSTS AND COLUMNS SECURED WITH NAILSS - JOINTS MISSING HANGERS COLUMN SPLICE CONNECTION IS APPROX 12" AND SECURED WITH NAILS - COLUMN BEAM CONNECTION MISSING STEEL ANGLES - COLUMNS NO FOUNDATION. PROVIDE PLAN AND PERMIT TO REPAIR OR REPLACE | 652 W GARFIELD BLVD | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | UNDER REAR PORCH - REFUSE ACCUMULATION | 652 W GARFIELD BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR NO ENTRY TO VERIFY OCCUPANCY - SMOKE AND CARBON MONOXIDE DETECTORS | 652 W GARFIELD BLVD | PERIODIC | FAILED | View |
NO POSTED ADDRESS | BUILDING MISSING OWNERS ID WITH NAME, ADDRESS, PHONE | 652 W GARFIELD BLVD | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NEVER REGISTERED | 652 W GARFIELD BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | FRONT ELEVATION WEST ELEVATION WASHED OUT MORTAR FRACTURED JOINTS | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
MAINTAIN PROJECTIONS | FRONT ELEVATION ORNAMENTAL LIMESTONE OPEN MORTAR JOINTS | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | 1ST FLOOR WEST ELEVATION LARGE GAPS IN REPLACEMENT WINDOWS | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH-GRADE TO 3RD IMPROPER FOOTINGS IMPROPER SPLICING OF COLUMNS IMPROPER STRINGER CONNECTIONS JOISTS TOO SMALL FOR SPAN JOINTS ON MID-LANDINGS HAVE NO JOIST HANGERS-TREADS TO NARROW, IMPROPER BEAM TOO COLUMN CONNECTIONS BEAMS NOT PROPERLY ANCHORED INTO BEAM PICKETS ROTTED MIDDLE COLUMN FROM 3RD TO ROOF ROTTED CEILING OF ROOF OF 3RD FLOOR RAILINGS TOO LOW | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMITS FOR ALL REPAIRS TO REAR PORCH | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | BASEMENT AND 1ST FLOOR REAR REMOVE BURGLAR GATES | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
ILLUMINATE EXIT AREAS | REAR PORCH NO LIGHTS | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
RATS | REAR YARD-RAT HOLES | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD AND BASEMENT STAIRWELL JUNK AND DEBRIS | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST ID | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | REGISTERED BUILDING | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
CHIMNEY | CHIMNEY LOOSE BRICKS AND WASHOUT MORTAR | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CHIMNEY CAP LOOSE AND WASHED OUT MORTAR | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | ERECTED NEW 6FT WROUGHT IRON FENCES AT ME NORTH, SOUTH, EAST, + WEST PROPERTY LINES. | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | RE-BUILDING EXISTING 8FT X 20FT 3-STORY FRAME OPEN REAR PORCH AT NORTH ELEVATION. | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP WORK ON PREMISES UNTIL A BUILDING PERMIT IS OBTAINED (13-12-080) (13-32-035) | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | FRONT ELEVATION/ WINDOW SILLS - WASHED OUT MORTAR. | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR CORNICE | FRONT ELEVATION/ ORNAMENTAL CORNICE ABOVE 3RD FLOOR WINDOWS - WASHED OUT MORTAR. | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
PARAPET | WEST ELEVATION/ PARAPET WALL - SPALLING BRICKS WITH WASHED OUT MORTAR. | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR 3-STORY WOOD PORCH/ COLUMNS ARE RESTING ON BRICKS AND SMALL CONCRETE BLOCKS, COLUMNS ARE SHIFTING OFF THESE BLOCKS. COLUMNS ARE DOUBLE NOTCHED FOR FIRE CUTS AND HEADER NOTCHES; COLUMN ARE WEAK WITH FIRE CUTS AND HEADER NOTCHES AT SAME LOCATION. COLUMN HALF LAP SPLICES ARE ONLY 12 INCHES IN LENGTH AND FASTENED WITH NAILS ONLY. LANDING COLUMNS ARE DOUBLE NOTCHED FOR RIM JOISTS. BEAMS ARE PULLING OUT OF FIRE CUTS AND ARE ONLY NAILED TO TO COLUMNS; OPEN WALL POCKETS WITH MISSING MORTAR. UNDERSIZE 2X6 DECK JOISTS SPAN 10 TO 11 FEET. LANDING RIM JOISTS ARE ONLY NAILED TO COLUMNS. LANDING DECK JOISTS ARE ONLY NAILED TO RIM JOISTS. STRINGERS - UPPER END ARE INADEQUATELY SUPPORTED WITH NAILS ONLY. ENTIRE LANDING IS WEAK AND UNSTABLE; SWAYS EXCESSIVELY. ALL RAIILING ARE LOOSE, PULLING AND ONLY NAILED TO COLUMNS AND POSTS. GUARD RAILINGS ARE ONLY 37 INCHES HIGH. STAIR TREADS ARE LOOSE. PLANS AND PERMIT ARE REQUIRED TO REPLACE REAR PORCH. | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
PARAPET & COPING | WEST ELEVATION WASHED OUT MORTAR AND MISSING COPING TILE AT BACK | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR FENCE | EAST ELEVATION REAR YARD REPAIR FENCE | 652 W GARFIELD BLVD | COMPLAINT | FAILED | View |