Chicago Building Violations Data: 23 Violations
Violation Inspector Comments Address Category Status View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTS THROUGH-OUT DANGEROUS AND HAZARDOUS 6019 S ALBANY AVE COMPLAINT FAILED View
WORK NOT ALLOWED BASEMENT- REMOVE ALL PARTITIONS AND FIXTURES(INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. 6019 S ALBANY AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR BASEMENT- SUBMIT AND PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE, 6019 S ALBANY AVE COMPLAINT FAILED View
CONTRARY TO ORIGINAL PLAN BASEMENT ORIGINALLY USED FOR STORAGE/MECHANICAL ROOM NOW THERE ARE NON-LOAD BEARING PARTITION FORMING BEDROOMS, KITCHEN, AND BATHROOM. 6019 S ALBANY AVE COMPLAINT FAILED View
EGRESS -BASEMENT BASEMENT DWELLING UNIT- ONLY ONE EGRESS EXIT. 6019 S ALBANY AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WASTE PIPING FIRST FLOOR REMOVE WASTE PIPE USED FOR THE WASHING MACHINE ON THE BACK PORCH,PIPE INSTALLED OUT SIDE OF BUILDING , KEEP FROM FREEZING.(18-29-102.3) 6019 S ALBANY AVE COMPLAINT FAILED View
PROVIDE TRAP FOR FIXTURE INSTALL A TRAP FOR THE BATH TUB, MISSING.(18029-1002) 6019 S ALBANY AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE REMOVE FLEX SUPPLIES TO ALL FIXTURES AND INSTALL COPPER SUPPLIES THROUGH OUT BUILDING.(18-29-605) 6019 S ALBANY AVE COMPLAINT FAILED View
INSTALL FIXTURES PROPER MATERL INSTALL A SAFE PAN UNDER WATER HEATER AND PIPE TO AN OPEN SITE WASTE.(18-29-402) 6019 S ALBANY AVE COMPLAINT FAILED View
OPEN PROVIDE A FLOOR DRAIN FOR THE WATER HEATER AND BOILER IN THE SAME ROOM.(18-29-412.4) 6019 S ALBANY AVE COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC HIRE A LICENSED PLUMBING CONTRACTOR TO CORRECT ALL PLUMBING VIOLATIONS.(18-29-106.1) 6019 S ALBANY AVE COMPLAINT FAILED View
CHIMNEY EXTERIOR CHIMNEY - WASHED OUT MORTAR JOINTS, AND MISSING CAP. 6019 S ALBANY AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR EXTERIOR FRONT MAIN ENTRY DOOR SPLIT AND BROKEN IN SEVERAL AREAS. 6019 S ALBANY AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR EXTERIOR REAR STAIRS MISSING HAND RAIL 6019 S ALBANY AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALLS ALL ELEVATIONS SPALLING BRICKS AND WASHED OUT MORTAR JOINTS. 6019 S ALBANY AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTORS THROUGH-OUT DANGEROUS AND HAZARDOUS 6019 S ALBANY AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ACCESS TO ATTIC 6019 S ALBANY AVE COMPLAINT FAILED View
INDIRECT CONN.FOR WATER SUPPLY BASEMENT INSTALL A APPROVED BACK FLOW PREVENTER ON THE COLD WATER SUPPLY TO THE BOILER. MODEL WATTS#9D 6019 S ALBANY AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE INSTALL PROPER ADAPTER ON THE HOT AND COLD WATER LINES TO WATER HEATER.(18-29-6050 ) 6019 S ALBANY AVE COMPLAINT FAILED View
SUBMIT PLANS FOR PLUMBING PRMT SUBMIT PLANS RO THE BUILDING,WATER AND SEWER DEPARTMENT FOR REVIEW AND PERMIT TO REMOVE BATH ROOM AND KITCHEN IN BASEMENT INSTALLED WITHOUT PERMITS. 6019 S ALBANY AVE COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK PULL A PLUMBING PERMIT TO CORRECT ALL PLUMBING VIOLATIONS.(18-29-106.1) 6019 S ALBANY AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR HARDWARE EXTERIOR FRONT MAIN ENTRY DOOR MISSING HARDWARE. 6019 S ALBANY AVE COMPLAINT FAILED View
PROVIDE EXTERIOR FENCE OVER 5' PROVIDE PERMIT (13-32-300) 6019 S ALBANY AVE COMPLAINT FAILED View