Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SAFE WORKING CONDITIONS | S.F.R., HVAC DUCTWORK HAS LARGE OPENNINGS ALLOWING WARM AIR TO ESCAPE TO AN UNFINISHED BASEMENT. | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY WOOD PORCH, 2ND FLOOR GUARDRAILS - LOOSE PICKETS.; RAILINGS MISSING TOP RAIL.; RAILING END POSTS TO WALL - FASTENED WITH NAILS ONLY.; RIM JOISTS, STRINGERS AND RAILING HORIZONTAL TIES ARE FASTENED WITH NAILS ONLY. | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EAST ELEVATION / GUARD RAILS - MISSING. | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO VERIFY CONDITIONS OF INTERIOR STAIRWAY, REAR ENCLOSED PORCH AND BASEMENT. | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
INSECTS | 1ST FLOOR APT - TENANT ALLEGES FLYING BUGS,INSECTS ORIGINATING FROM BASEMENT. (COULD NOT RECORD EVIDENCE TO SUPPORT ALLEGATION) | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
PARAPET | PARAPET WALL - STEP FRACTURES | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT ENTRY DOOR - PLEXIGLASS IN LIEU OF TEMPERED GLASS PANE | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | FRONT ENTRY DOOR JAMB - ROTTING TRIM; PAINT PEELING | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WEST, NORTH ELEVATIONS - WINDOW FRAMES, SASHES - ROTTING; PAINT PEELING | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST - FRONT PORCH/1ST FLOOR LANDING - HEADER AT NORTH CORNER - ROTTING;EAST - REAR PORCH - FOUNDATION STATUS UNKNOWN; 6X6 AND 4X6 COLUMNS OVERNOTCHED; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; SPINDLES ON OUTSIDE ASPECT OF RAILS; HANDRAIL LEANING FROM 1ST TO 2ND FLOOR. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | CORNICE - CRACKED; BROKEN; WASHED OUT MORTAR | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH - 1ST FLOOR - WINDOW - BOARDED;EAST - 2ND FLOOR/ REAR ENCLOSED PORCH - WINDOW - BOARDED | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAILS - SPINDLES MISSING; FALL HAZARD | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
NO CLOSET/STORAGE UNDER STAIR | REAR PORCH - DISCARDED APPLIANCE STORED UNDERNEATH REAR STAIRS | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | BASEMENT - RETAINING WALL - BRICKS BULGING; LEANING | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE; NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, AND ENCLOSED AREAS OF REAR PORCH. UNVERIFIED DETECTORS AND OCCUPANCY. | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, REAR PREMISES, AND REAR PORCH. UNVERIFIED DETECTORS AND CONDITIONS. | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT CONCRETE STAIRS - PAINT PEELING | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | FRONT ENTRY DOOR - ROTTING FRAME; PAINT PEELING | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO POSTING OF OWNERSHIP-REFUSED ENTRY | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT CONCRETE EXTERIOR STAIR WALLS-ERODED MORTAR JOINTS | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
SEAL CONDUIT OPENING | PATCH HOLES | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
SUPPLEMENTAL GROUND | NO SUPPLEMENTAL GROUND | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | SOUTH ELEVATION / WINDOWS MADE SMALLER. NORTH ELEVATION / WINDOW - BOARD UP 1ST AND 2ND FL .PERMIT REQUIRED FOR WINDOW MADE SMALLER . | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | WEST ELEVATION /1ST AND 2ND FL LINTELS- BENT. PERMIT REQUIRED TO REPLACE LINTELS. | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION / 2 STORY PARTIALLY ENCLOSED PORCH / COLUMNS - ERECTED ON CONCRETE BLOCKS. FOUNDATION STATUS - UNKNOWN. COLUMNS - TWISTING. BEAM AT 1ST FLOOR - PULLING AWAY AT FIRE CUT. JOISTS - NOTCHED AROUND SINGLE 2X8 END BEAMS. BEAM TO BEAM CONNECTION - FASTENED WITH NAILS ONLY. STRINGERS - - ROTTING AND CRACKED. UPPER ENDS OF STRINGERS - FASTENED WITH NAILS ONLY. RISER HEIGHT VARIES FROM 7 INCHES TO 11 INCHES. ALL RAILING SYSTEMS - FASTENED WITH NAILS ONLY. RAILING PULLING AWAY FROM COLUMNS.PLANS AND PERMIT TO REPLACE REAR WOOD PORCH. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 7425 S PRINCETON AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO VERIFY CONDITIONS OF INTERIOR STAIRWAY, REAR ENCLOSED PORCH AND BASEMENT. | 7425 S PRINCETON AVE | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | SHOPPING CART IN REAR YARD | 7425 S PRINCETON AVE | COMPLAINT | FAILED | View |