Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
OBSTRUCTIONS IN EXIT WAY | EAST AND WEST GATE PADLOCK | 5915 S ADA ST | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | PORCH UNDER CONSTRUCTION - NO GUARDRAILS / NO STEEL STRAPS / NO FOOTING ON NORTH EAST COLUMN / NO HANDRAILS AND MISSING PICKETS / LEDGERS NOT BOLTED. PROVIDE PLANS AND PERMITS - (CONTRARY TO PERMIT). | 5915 S ADA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | OPEN JOINTS, WASHED OUT MORTAR - SOUTH AND EAST AT REAR PORCH. | 5915 S ADA ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | JUNK AND DEBRIS REAR YARD. | 5915 S ADA ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROVIDE PLANS AND PERMIT FOR REAR PORCH UNDER CONSTRUCTION. | 5915 S ADA ST | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | ARRANGE FOR INTERIOR INSPECTION FOR PORCH. NEED PLANS AND ORIGINAL PERMIT. (PORCH HAS BEEN BUILT) | 5915 S ADA ST | PERMIT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION / EXTERIOR STAIR - GRADE TO 1ST FL .2X4 USED AS COLUMNS. 2X4 COLUMNS COLUMNS ERECTED ON DIRT.STRINGERS CRACKED LEDGER BOARD NAILED TO WALL . JOIST NAILED TO HEADERS .RISER DIFFERENT HIGHTS GUARD RAILS LOOSE. | 5915 S ADA ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | FRONT INTERIOR STAIR / EXPOSE WIRE - OPEN ELECT BOX. | 5915 S ADA ST | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | NORTH AND EAST ELEVATION / 3 DOWNSPOUT - 10 FT LONG MISSING . | 5915 S ADA ST | COMPLAINT | FAILED | View |
REPAIR FENCE | NORTH ELEVATION / WOODEN FENCE - 8X6 FT SECTION MISSING . PICKETS BROKEN .PERMIT REQUIRED TO REPAIR NORTH FENCE | 5915 S ADA ST | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | FRONT INTERIOR STAIR/ VIEWING DEVICE -1ST AND 2ND FL APT FRONT INTERIOR DOOR VIEWING DEVICE MISSING . | 5915 S ADA ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | EAST ELEVATION / NUISANCE- GRADE AND 1ST FL TRASH BAGS.GRADE OF REAR PORCH GAS TANKS . | 5915 S ADA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION/ EXTERIOR WALL - 2ND FL LARGE STEP CRACKS. NORTH ELEVATION / EXTERIOR WALL - GRADE TO 1ST FL WALL3X8FT HIGH BULGING OUT WITH LOOSE BRICKS. | 5915 S ADA ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION / EXTERIOR PORCH - GRADE TO 2ND FL 6X6 COLUMN FOUNDATION BULGING OUT WITH LOOSE STONE . GUARDRAILS LOOSE AND MISSING PICKETS.GUARDRAILS NAILED TO WALL . PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH . | 5915 S ADA ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIR/ SMOKE DETECTOR -MISSING ON TOP LANDING. | 5915 S ADA ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | EAST ELEVATION / FOUNDATION / UNDER THE PORCH BULGING OUT 3X4X3FT HIGH SECTION .PERMIT REQUIRED TO REPAIR FOUNDATION. | 5915 S ADA ST | COMPLAINT | FAILED | View |
REPAIR ROOF | SOUTH ELEVATION / ROOF - MISSING 2X3 FT SECTION OF SHINGLES. | 5915 S ADA ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WEST ELEVATION / WINDOW PANE - BASEMENT AND 2ND FL PANE BROKEN . | 5915 S ADA ST | COMPLAINT | FAILED | View |
MAINTAN BLDG IN SAFE CONDITION | 5915 S ADA ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 5915 S ADA ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 5915 S ADA ST | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 5915 S ADA ST | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 5915 S ADA ST | COMPLAINT | CLOSED | View | |
OBTAIN OR POST PERMIT | 5915 S ADA ST | COMPLAINT | CLOSED | View | |
CHIMNEY | CHIMNEY BROKEN BRICKS, LOOSE AND MISSING | 5915 S ADA ST | COMPLAINT | CLOSED | View |
CHIMNEY CAPPING | CHIMNEY NO CAPPING | 5915 S ADA ST | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | EAST PORCH IMPROPER FIRECUT NO LEDGER BOLTS NO FOOTING, IMPROPER RAIL HEIGHT AND IMPROPER RAIL PICKE, LOOKOUT NOT SEAL IN WALL, STRINGERS NOT SITTING ON DECKING PROPERLY, WEST PORCH UPRIGHT TOP CAP MISSING FOR ROOF SUPPORT, RAILS LOOSE | 5915 S ADA ST | COMPLAINT | CLOSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS PERMITS FOR REPAIRS | 5915 S ADA ST | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | BASEMENT AND EAST WINDOW PANES BOARDED UP | 5915 S ADA ST | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP | 5915 S ADA ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SERVICE WALK BROKEN CONCRETE | 5915 S ADA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL MORTAR MISSING | 5915 S ADA ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | NORTH SECTION OF GUTTED DEBRIS (SEC 13-168-600) | 5915 S ADA ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY OPEN WOOD PORCH WITH ROOF AND BASEMENT ACCESS - SOME MEMBERS ARE WARPED AND IN EARLY STAGES OF ROTT | 5915 S ADA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | (1) NORTH BRICK EXTERIOR WALL WEST END FROM GRADE UP TO THE 2ND FLOOR - SEVERELY WASHED OUT MORTAR JOINTS WITH MISSING AND SPALLED BRICKS THAT BULGE OUTWARD OVER THE PUBLIC ALLEY - IMMINENTLY DANGEROUS AND HAZARDOUS(2) NORTH BRICK EXTERIOR WALL VARIOUS WINDOW OPENINGS AT ARCHED LINTELS - FRACTURES WITH WIDE OPEN GAPS AND DISPLACED MISALIGNED BRICK(3) NORTH, SOUTH AND EAST EXTERIOR WALLS - VARIOUS LOCATIONS - WASHED OUT BRICK MORTAR JOINTS(4) PERMIT REQUIRED FOR MASONRY REPAIRS | 5915 S ADA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT RAISED OPEN WOOD STAIR WITH ROOF -(1) ALL WOOD MEMBERS ROTTED WITH JOINTS PULLING CREATING LARGE GAPS THAT EXPOSE RUSTING NAILS(2) JOIST HANGERS AND BOLTED CONNECTIONS MISSING(3) COLUMNS BEAR ON CONCRETE BLOCKS WITH UNKNOWN FOUNDATIONS(4) STAIR HANDRAILS ARE ONLY 24INCHES HIGH AND LANDING GUARDRAILS ARE ONLY 26INCHES HIGH - ALL ARE WEAK AND MOVES WHEN GRABBED | 5915 S ADA ST | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | FRONT 1ST FLOOR BAY WINDOW AT PORCH - LARGE GAPS AROUND THE FRAME WITH BLOCKING AND SEALANT MISSING AND ALLOW SUBSTANTIAL AIR SEEPAGE AND INSECTS INSIDE (14X-3-303.13 AND 14X-12-1202.4.3.3) | 5915 S ADA ST | COMPLAINT | FAILED | View |