Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
NO KEY TO USE EXIT DOOR | THREE FONT YARD GATES - DOUBLE KEY LOCKS. | 1733 N TALMAN AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | FRONT 2-STORY WOOD PORCH/ CORNER COLUMNS - DOUBLE NOTCHED FOR RIM JOISTS. RIM JOISTS ONLY NAILED TO LEDGER BEAM.STRINGERS - INADEQUATELY SUPPORTED WITH SCREWS ONLY. STRINGERS SPLIT WHERE TREAD IS SCREWED IN. 1ST TO 2ND LANDING - HEED HEIGHT ONLY 74 INCHES. RAILINGS - ONLY 38 INCHES HIGH, BOTTOMS LOOSE AND PULLING; ONLY SCREWED TO COLUMNS. STAIR RAILINGS - LOOSE, PULLING AND ONLY SCREWED TO POSTS.PLANS AND PERMIT REQUIRED TO REPAIR PORCH.REAR 2-STORY WOOD PORCH/ RIM JOISTS ONLY NAILED TO COLUMNS. SOUTH LEDGER ONLY NAILED TO BUILDING'S EXTERIOR WALL. STRINGERS WEAK WITH ONLY 4 INCHES OF DEPTH. AND UPPER ENDS ARE INADEQUATELY SUPPORTED WITH SCREWS ONLY. RAILINGS - ONLY 40 INCHES HIGH, LOOSE AND POULLING; ONLY SCREWED TO POSTS. STAIR RAILINGS - LOOSE AND PULLING; ONLY SCREWED TO POSTS. SOUTH 2ND FLOOR RAILINGS - ONLY 36 INCHES HIGH , LOOSE AND PULLING; ONLY SCREWED TO COLUMNS. TREADS - LOOSE AND ROTTED.RISERS - 9 TO 11 INCHES HIGH.PLANS AND PERMIT REQUIRED TO REPAIR PORCH. | 1733 N TALMAN AVE | COMPLAINT | PASSED | View |
NO KEY TO USE EXIT DOOR | THREE FONT YARD GATES - DOUBLE KEY LOCKS. | 1733 N TALMAN AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH ELEVATION / SERVICE WALK-CRACKED CONCRETE. | 1733 N TALMAN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT ELEVATION / 2 STORY EXTERIOR WOOD PORCH.LEDGER BEAM BOLTS-SPACED 42 INCHES APART.6X6 COLUMNS SET ON CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN,COLUMNS MISSING METAL BASE PLATES,COLUMNS OVER NOTCHED.SINGLE 2X8 BEAM ONLY FACE NAILED TO SUPPORTS.STRINGERS ARE SPLITTING,ONLY FACE NAILED AT TOP CONNECTION.MID-LANDING HEAD HEIGHT ONLY 74 INCHES.JOISTS HANGERS MISSING NAILS.RAILINGS MISSING 4X4 CENTER SUPPORTS.DECKING IS SPLITTING.PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS.REAR 2 STORY EXTERIOR WOOD PORCH WITH SOUTH SIDE 2ND FLOOR CAT WALK..SOUTH ELEVATION CAT WALK-6X6 AND 4X4 COLUMNS SET ON CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN.4X4 COLUMNS SPAN OVER 14 FEET.REAR PORCH 4X6 COLUMNS SET ON CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN.UNDER SIZED 2X6 JOISTS SPAN 11 FEET.STRINGERS ONLY FACE NAILED AT TOP CONNECTION.RISER NOT UNIFORM HEIGHT,RANGING FROM 7 INCHES TO 11 INCHES ALSO 5 INCHES TO 9 INCHES.JOISTS ONLY FACE NAILED TO SUPPORTS.LEDGER BEAM ONLY FACE NAILED TO BUILDING.RAILINGS ARE LOOSE AND PULLING MISSING 4X4 CENTER SUPPORTS.PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. | 1733 N TALMAN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | REAR ELEVATION / EXTERIOR STAIRS,GRADETO BASEMENT-MISSING HAND RAIL. | 1733 N TALMAN AVE | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR ELEVATION / EXTERIOR STAIRS,GRADE TO BASEMENT-MISSING GUARD RAIL. | 1733 N TALMAN AVE | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH ELEVATION / SERVICE WALK-CRACKED CONCRETE. | 1733 N TALMAN AVE | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR ELEVATION / EXTERIOR STAIRS,GRADE TO BASEMENT-MISSING GUARD RAIL. | 1733 N TALMAN AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT ELEVATION / 2 STORY EXTERIOR WOOD PORCH.LEDGER BEAM BOLTS-SPACED 42 INCHES APART.6X6 COLUMNS SET ON CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN,COLUMNS MISSING METAL BASE PLATES,COLUMNS OVER NOTCHED.SINGLE 2X8 BEAM ONLY FACE NAILED TO SUPPORTS.STRINGERS ARE SPLITTING,ONLY FACE NAILED AT TOP CONNECTION.MID-LANDING HEAD HEIGHT ONLY 74 INCHES.JOISTS HANGERS MISSING NAILS.RAILINGS MISSING 4X4 CENTER SUPPORTS.DECKING IS SPLITTING.PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS.REAR 2 STORY EXTERIOR WOOD PORCH WITH SOUTH SIDE 2ND FLOOR CAT WALK..SOUTH ELEVATION CAT WALK-6X6 AND 4X4 COLUMNS SET ON CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN.4X4 COLUMNS SPAN OVER 14 FEET.REAR PORCH 4X6 COLUMNS SET ON CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN.UNDER SIZED 2X6 JOISTS SPAN 11 FEET.STRINGERS ONLY FACE NAILED AT TOP CONNECTION.RISER NOT UNIFORM HEIGHT,RANGING FROM 7 INCHES TO 11 INCHES ALSO 5 INCHES TO 9 INCHES.JOISTS ONLY FACE NAILED TO SUPPORTS.LEDGER BEAM ONLY FACE NAILED TO BUILDING.RAILINGS ARE LOOSE AND PULLING MISSING 4X4 CENTER SUPPORTS.PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. | 1733 N TALMAN AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ENTRY REFUSED BY 1ST FLOOR TENANT. 2ND FLOOR - MINOR HOME ALONE, ON ADULT PRESESNT. BASEMENT - NO RESPONSE. UNABLE TO VERIFY DETECTORS. CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 1733 N TALMAN AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | REAR ELEVATION / EXTERIOR STAIRS,GRADETO BASEMENT-MISSING HAND RAIL. | 1733 N TALMAN AVE | COMPLAINT | FAILED | View |