Last Modification Date: 2024-10-24 @ 12:49 PM
PIN: 20094080070000
Property Address: 313 W 52ND ST
City - Zip: CHICAGO - 60609
2023 Property Class: 100
2023 Township: 72 - Lake
2023 Neighborhood: 72092
2023 Tax District: 72102
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 34 Violations
Violation Inspector Comments Address Category Status View
ARMORED CABLE REPLACE ROTTED (BOX) ARMORED CABLE AT REAR PORCH 2ND LANDING 313 W 52ND ST COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE DEFECTIVE LIGHTING AT REAR PORCH 313 W 52ND ST COMPLAINT FAILED View
INSTALL ILLUMINATION INSTALL LIGHTING AT ALL EXTERIOR ENTRANCES 313 W 52ND ST COMPLAINT FAILED View
SEE INSPECTOR COMMENTS REPLACE BADLY FRAYED SERVICE ENTRANCE CABLE USED AS RISER 18-27-110.12 313 W 52ND ST COMPLAINT FAILED View
CIRCUIT ONE UNIT ONLY PROVIDE PUBLIC AREA METER AND PANEL FOR A;; PUBLIC AREAS OF BUILDING PRESENTLY 3RD METER FEEDING BASEMENT APARTMENT,A PERMIT IS REQUIRED TO CORRECT ALL VIOLATIONS 313 W 52ND ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALLS-LOOSE, TORN, MISSING SIDING; EXPOSED ROTTED WOODEN MEMBERS 313 W 52ND ST COMPLAINT FAILED View
MAINTAIN PROJECTIONS AWNING-ROTTED PLYWOOD SHEATHING; HOLES. 313 W 52ND ST COMPLAINT FAILED View
REPAIR WINDOW SILLS WINDOW SILLS-WORN, ROTTED, PEELING PAINT. 313 W 52ND ST COMPLAINT FAILED View
REPAIR EAVES EAVES-WORN, ROTTED, PEELING PAINT. 313 W 52ND ST COMPLAINT FAILED View
REPAIR AREAWAY WALL AREAWAY WALL-SHIFTING; ERODED MORTAR. 313 W 52ND ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR EXTERIOR STAIRS-FRACTURED, SPALLED CONCRETE TREADS. 313 W 52ND ST COMPLAINT FAILED View
REPLACE D&H PORCH FRONT PORCH-COLUMNS ARE SET ON FRACTURED CONCRETE PADS; FOUNDATIOIN STATUS IS UNKNOWN; COLUMNS SUPPORTING THE 2ND FLOOR LANDING ARE SET ON TOP OF THE FIRST FLOOR LANDING DECK BOARDS, WEST COLUMN IS ROTTED, EAST COLUMN IS SCABBED TOGETHER AT THE BUTT JOINT. BEAMS/RIM JOISTS ARE ONLY NAILED INTO THE BEAMS/POSTS WITH SEPERATION AT THE CONNECTIONS; FRACTURED HEADER BEAM SUPPORTING THE MID-LANDING. ROTTED DECK JOISTS SUPPORTING THE 1ST FLOOR LANDING. STRINGERS ARE ONLY NAILED INTO THE COLUMN/POST/DECK BRIDGING CONNECTIONS; WEST STRINGER FROM (1) TO MID-LANDING IS FRACTURED. MID-LANDING NOTICEABLY SHIFTS UPON LOAD. WORN TREADS AND RISERS; NAILS PROTRUDING OUT. WORN, BROKEN, LOOSE, ONLY 32 INCH HEIGHT GUARDRAILS; BROKEN AND MISSING PICKETS. ROTTED, BUCKLED UP DECK BOARDS. LANDINGS ARE NOTICEABLY PITCHED DOWNWARD TOWARD NORTH. MOST MEMBERS ARE ONLY TOE NAILED TOGETHER WITH SEPERATION AT THE CONNECTIONS. REAR PORCH-COLUMNS ARE SET IN SOIL AND CONCRETE BASES; FOUNDATION STATUS IS UNKNOWN; COLUMNS ARE SEPERATING FROM THE 4X6 BEAMS SUPPORTING THE 2ND FLOOR.BEAMS/RIM JOISTS ARE ONLY NAILED INTO THE COLUMN/POST CONNECTIONS. UNDERSIZED 2X6 JOISTS FOR A 14 FEET 7 INCH SPAN. STRINGERS ARE ONLY NAILED INTO THE COLUMN POST CONNECTIONS;STRINGERS FROM MID-LANDING TO (2) ARE SEPERATING FROM THE 4X6 BEAM CONNECTION; SOUTH STRINGER IS FRACTURED. FLIGHT FROM (GRADE) TO (MID-LANDING) NOTICEABLY SHIFTS UPON LOAD. WORN, ROTTED TREADS AND RISERS; NAILS PROTRUDING OUT. LOOSE HANDRAILS; EAST HANDRAIL WITH LOOSE, WORN PLYWOOD IN LIEU OF PICKETS. ONLY 32 INCH HEIGHT GUARDRAILS. LOOSE, BUCKLED UP DECK BOARDS. PEELING PAINT.DANGEROUS AND HAZARDOUS CONDITIONS. PLANS AND PERMIT REQUIRED FOR FRONT / REAR PORCH REPLACEMENT. 313 W 52ND ST COMPLAINT FAILED View
PROVIDE GUTTER & DOWNSPOUT GUTTERS / DOWNSPOUTS-MISSING. 313 W 52ND ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS WINDOW PANE-BROKEN. 313 W 52ND ST COMPLAINT FAILED View
MAINTAIN WINDOW WINDOW FRAMES-ROTTED, WORN, PEELING PAINT. 313 W 52ND ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# OWNER'S I.D. SIGN-NOT POSTED. 313 W 52ND ST COMPLAINT FAILED View
MAINTAIN WINDOW SASH WINDOW SASH-WORN. 313 W 52ND ST COMPLAINT FAILED View
REPLACE D&H PORCH FRONT AND REAR PORCHES ARE DANGEROUS AND HAZARDOUS. A) FRONT PORCH HAS FAILED CONNECTIONS OF RAILS AND STRINGERS. ENTIRE 2 STORY PORCH SHAKES AND SWAYS AND HAS EXCESSIVE PITCH. HAS ROTTED, BROKEN AND BUCKLED BOARDS AT DECK AND LANDING.. NO FOUNDATION. ALSO ROOF OVER FRONT PORCH IS ROTTED.B) REAR PORCH CONNECTIONS OF RAILS AND STRINGERS ARE INADEQUATE. STRINGERS ARE BROKEN AND PLYWOOD IS USED IN PLACE OF RAILS AND PICKETS. RAILS ARE LOW, NO APPARENT FOUNDATION. OVERALL CONDITION OF PORCHES IS DANGEROUS AND HAZARDOUS. SUBMIT COMPLETE DETAILED PLANS AND OBTAIN PERMIT. 313 W 52ND ST COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT MISSING GUTTERS AND DOWNSPOUTS. 313 W 52ND ST COMPLAINT FAILED View
REPAIR EAVES EAVES ARE ROTTED AT NORTH ELEVATION. 313 W 52ND ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# OWNERSHIP IS NOT POSTED. 313 W 52ND ST COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED FRAME GARAGE IS MISSING SIDING AT TOP ALL AROUND GARAGE. WEST ELEVATION SIDING IS WARPED. 313 W 52ND ST COMPLAINT FAILED View
MAINTAIN WINDOW ALL ELEVATIONS WOOD TRIM HAS PAINT PEELING. 313 W 52ND ST COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH GRADE TO BASEMENT DROP OFF MISSING GUARDRAIL. 313 W 52ND ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR NORTH ELEVATION STAIRS TO BASEMENT MISSING HANDRAIL. 313 W 52ND ST COMPLAINT FAILED View
SAFE WORKING CONDITIONS SPACE HEATER-OUT OF SERVICE AT TIME OF INSPECTION. 313 W 52ND ST COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE UTILIZING COOKING STOVE AS HEATING DEVICE. 313 W 52ND ST COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS SMOKE DETECTOR-LOW BATTERY SIGNAL ACTIVATED. 313 W 52ND ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS BROKEN WINDOW AT 2ND FLOOR NORTH ELEVATION. 313 W 52ND ST COMPLAINT FAILED View
REPLACE D&H PORCH FRONT TWO STORY PORCH DANGEROUS AND HAZARD- COLUMNS ROTTED AND RESTING ON DIRT, FOOTING UNKNOWN, UNABLE TO VIEW JOISTS- COVER WITH ROTTED WOOD. STRINGERS OVERCUT, STEPS DIFFER SIZE, DECKING PULLING AWAY AT WALLS WITH ROTTED BOARDS, RISERS AND PICKETS MISSING, RAILS 32"INCHES HIGH AND LOOSE. PLAN AND PERMIT REQUIRE FOR PORCH.REAR PORCH COVER WITH SNOW, RAIL 32"INCHES AND MISSING PICKETS. 313 W 52ND ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER'S ID SIGN POSTED. 313 W 52ND ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EXTERIOR WALL MISSING AND LOOSE SIDING. 313 W 52ND ST COMPLAINT FAILED View
ADD RECEPTACLES EXTENSION CORD THRU THE WINDOW OPENINGS. 313 W 52ND ST COMPLAINT FAILED View
CHIMNEY CAPPING CHIMNEY IS MISSING CAP. 313 W 52ND ST COMPLAINT FAILED View