Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR/REPLACE SMOKE DETECTORS | 7344, BASEMENT: SMOKE DETECTOR INOPERABLE | 7342 S KINGSTON AVE | PERIODIC | PASSED | View |
REPAIR PORCH SYSTEM | 7346 WOOD PORCH: COLUMN MISSING FOUNDATION, JOISTS MISSING HANGERS, COLUMNS SPLICES TOE-NAILED, GUARD RAILS BELOW 42", HANDRAIL, GRADE TO LEVEL 1, MISSING PICKETS, GUARD RAILS NOT BOLTED TO MASONRY WALL, STRINGERS NOT BOLTED TO MASONRY WALL; 7344 WOOD PORCH: COLUMN MISSING FOUNDATION, JOISTS MISSING HANGERS, COLUMN SPLICES TOE-NAILED, GUARD RAILS BELOW 42", STRINGERS NOT BOLTED TO MASONRY WALL; 7342 WOOD PORCH: COLUMN AT BASEMENT UNDERCUT AND NOT RESTING ON GROUND, JOISTS MISSING HANGERS, COLUMN SPLICES TOE-NAILED, GUARD RAILS BELOW 42" AND NOT BOLTED TO MASONRY WALL, STRINGERS NOT BOLTED TO MASONRY WALL, 2ND LEVEL STRINGER CRACKED AND REPAIRED WITH SCABBED WOOD-STRINGER PULLING APART CAUSING FLIGHT OF STAIRS TO BE UNSTABLE, OPEN BEAM POCKET AT LEVEL 1; OBTAIN PLANS AND PERMIT | 7342 S KINGSTON AVE | PERIODIC | PASSED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION/ EXTERIOR WALL - SPALLING BRICKS WITH WASHED OUT MORTAR AT MULTIPLE LOCATIONS. | 7342 S KINGSTON AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | SOUTH AND WEST ELEVATIONS/ VARIOUS WINDOW SILLS - WASHED OUT MORTAR. | 7342 S KINGSTON AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 7344 S./ REAR 3-STORY WOOD POCKET PORCH/ ROOF BOARDS - ROTTED. 2ND FLOOR LANDING/ GUARD RAILINGS - BROKEN PICKETS. | 7342 S KINGSTON AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | SOME AREAS OF INTERIOR OF BUILDING AND ALL APARTMENTS - NO RESPONSE, NO ENTRY. UNBLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. UNABLE TO COMPLETE INTERIOR INSPECTION FOR 2017 ANNUAL INSPECTION. | 7342 S KINGSTON AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED FOR 2017. | 7342 S KINGSTON AVE | PERIODIC | FAILED | View |