Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 5:17 PM
PIN: 13362210010000
Property Address: 2205 N ROCKWELL ST
City - Zip: CHICAGO - 60647
2023 Property Class: 315
2023 Township: 77 - West Chicago
2023 Neighborhood: 77030
2023 Tax District: 77135
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 53 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR WALL 2569 EXTERIOR WALL BY WINDOWS;BUCKLING OUT 2205 N ROCKWELL ST PERIODIC FAILED View
CHIMNEY CHIMNEY;MORTAR MISSING 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR EXTERIOR WALL 2569 EXTERIOR WALL BY WINDOWS;BUCKLING OUT 2219 WEST EXTERIOR WALL 3RD FLR.;BUCKLING OUT 2205 N ROCKWELL ST PERIODIC FAILED View
CHIMNEY CHIMNEY;MORTAR MISSING 2205 N ROCKWELL ST PERIODIC FAILED View
CHIMNEY CHIMNEY;MORTAR MISSING 2205 N ROCKWELL ST PERIODIC FAILED View
FILE BLDG REGISTRATION REGISTER BUILDING FOR 1990 THRU 2011 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR PORCH SYSTEM 2573 PORCH;UPRIGHT OVERNOTCH,IMPROPER PICKET SPACING,GUARD RAILS SPLIT AND PULLING AWAY FROM SUPPORTS,WOOD TREADS SPLIT 2221 PORCH;6X6 UPRIGHT OVERCUT[USING WOOD SHIMS],STRINGERS BROKEN,G TO 3RD FLR.STRINGERS NOT SUPPORTED PROPERLY 2569 PORCH;6X6 UPRIGHT TWISTED AND SEPARATING,IMPROPER PICKET SPACING 2213 PORCH;IMPROPER PICKET SPACING,TREAD WINDERS NO SUPPORT AND PULLING AWAY 2215 PORCH;IMPROPER PICKET SPACING,6X6 UPRIGHTS LAP JOINTS SEPARATING 2219 PORCH;IMPROPER PICKET SPACING 2211 PORCH;6X6 UPRIGHT BOWED,IMPROPER PICKET SPACING,GUARD RAILS PULLING AWAY FROM SUPPORTS,STRINGERS NOT BOLTED TO THE WALL 2213 PORCH;STRINGER BROKEN,3RD FL.STRINGER AWAY FROM THE WALL 2213,2211,2219,2217,2215,2213,2569,2221,2573 PORCH SYSTEMS GUARD RAIL SUPPORTS ON THE WALL NOT SUPPORTED PROPERLY.[PERMITS FOR REPAIRS] 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR PORCH SYSTEM 2573,2569 AND 2215 3ST.PORCH SYSTEMS;6X6 UPRIGHT OVERNOTCH,OUT OF PLUMB AND TWISTED,LAP JOINTS PULLING APARTMENT, GUARD RAILS SPLIT AND PULLING AWAY FROM SUPPORTS,WOOD TREADS SPLIT,METAL BRACKETS ON PORCH RUSTED,UPRIGHTS NOT ON CENTER OF PIER BLOCKS,BOTTOM OF UPRIGHTS RUSTED BECAUSE OF METAL BRACKETS. 2219 3ST.PORCH; TREAD WINDER SMAL TREAD CUT IN FRONT,STRINGERS NOT BOLTED TO SUPPORTS,REPLACE 4X4 UPRIGHTS WITH 6X6S,SCAB WOOD ATTACH TO GUARD RAIL WALL SUPPORTS,TREAD WINDERS NOT SUPPORTED PROPERLY. 2221 3ST.PORCH; UPRIGHTS NOT SITTING ON THE CENTER OF PIER BLOCK,6X6S OVERCUT [USING WOOD SHIMS]GTO1ST STRINGER BROKEN AND HAND RAIL LOOSE,STRINGERS SUPPORTED PROPERLY,6X6 UPRIGHT LAP JOINT PULLING APART,GUARD RAILS WOOD SPLIT AND PULLING AWAY FROM SUPPORTS,LANDING WOOD DECK SPLIT AND WEAK,SMALL PIECE OF DECKING USED FOR NOSING,URIGHTS BOWED AND TWISTED,REPLACE 4X4 UPRIGHT WITH 6X6 AND OVERNOTCH,UPRIGHTS NOT SITTING ON CENTER OF PIER BLOCKS.2217 3ST.PORCH; UPRIGHTS OUT OF PLUMB AND OVERNOTCH,STRINGERS NOT SUPPROTED PROPERLY,GUARD RAILS WOOD SPLIT AND PULLING AWAY FROM SUPPORTS,DECKING WOOD SPLIT,REPLACE 4X4 UPRIGHTS WITH 6X6S. 2205 3ST.PORCH; GUARD RAIL WALL SUPPORT NOT BOLTED TO THE WALL,STRINGERS NOT SUPPORTED PROPERTLY,REPLACE 4X4 UPRIGHT WITH 6X6S,METAL BRACKETS RUSTED. 2209 3ST PORCH; TREADS WOOD SPLIT,6X6 UPRIGHT NOT SITTING ON CENTER OF PIER BLOCK AND RUSTED BRACKET,6X6 UPRIGHTS TWISTED AND OVERNOTCH,GUARD RAILS WOOD SPLIT AND PULLING AWAY FROM SUPPORTS,LEDGER BOARD PULLING AWAY FROM THE WALL,OUT SID RIM JOIST OVERCUT,REPLACE 4X4 WITH 6X6S. 2207,2211 3ST.PORCH; UPRIGHTS OVERNOTCH AND BOWED,TREAD WINDERS WEAK,WOOD SHIMS ATTACH TO RIM JOIST,STRINGER NOT BOLTED TO SUPPORTS,4X4 UPRIGHT SITTING ON RIM JOIST FOR STRINGER SUPPORTS,METAL BRACKETS RUSTED. 2213 3ST.PORCH; 6X6 UPRIGHTS BOWED AND TWISTED,UPRIGHT LAP JOINTS PULLING APART,STRINGER DETERIORATING AND SUPPORTED PROPERLY,4X4 POST ROTTED AND WEAK,PICKETS IMPROPER SPACING AND WEAK,GUARD RAILS WOOD SPLIT AND WEAK.[SUBMIT PLANS AND PERMITS FOR REPAIRS] 2221 PORCH;6X6 UPRIGHT OVERCUT[USING WOOD SHIMS],STRINGERS BROKEN,G TO 3RD FLR.STRINGERS NOT SUPPORTED PROPERLY 2569 PORCH;6X6 UPRIGHT TWISTED AND SEPARATING,IMPROPER PICKET SPACING 2213 PORCH;IMPROPER PICKET SPACING,TREAD WINDERS NO SUPPORT AND PULLING AWAY 2215 PORCH;IMPROPER PICKET SPACING,6X6 UPRIGHTS LAP JOINTS SEPARATING 2219 PORCH;IMPROPER PICKET SPACING 2211 PORCH;6X6 UPRIGHT BOWED,IMPROPER PICKET SPACING,GUARD RAILS PULLING AWAY FROM SUPPORTS,STRINGERS NOT BOLTED TO THE WALL 2213 PORCH;STRINGER BROKEN,3RD FL.STRINGER AWAY FROM THE WALL 2213,2211,2219,2217,2215,2213,2569,2221,2573 PORCH SYSTEMS GUARD RAIL SUPPORTS ON THE WALL NOT SUPPORTED PROPERLY.[PERMITS FOR REPAIRS] 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR PORCH SYSTEM TEN WOOD THREE STORY PORCHES,DECKS STAINED WITH ALL COMPONENTS WORN AND WEATHERED FINISH.SIMILAR DEFECTS THROUGHOUT.UPRIGHTS ARE NOTCHED AND DOUBLE NOTCHED.2X8 UNDER SIZED FLOOR JOISTS OVER SPANED TO 10 FEET AT DECKS AND LANDINGS.HARDWARE BOLTS AND BRACKETS ARE RUSTED.HANDRAILS AND GUARDRAILS ONLY NAILED TO SUPPORTS.LANDING GUARDRAILS OVERSPANNED WITHOUT CENTER SUPPORT POSTS.PICKETS LOOSE AND OVER SPACED.PLANS AND PERMIT REQUIRED FOR REPAIRS. 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR PORCH SYSTEM 2573,2569 AND 2215 3ST.PORCH SYSTEMS;6X6 UPRIGHT OVERNOTCH,OUT OF PLUMB AND TWISTED,LAP JOINTS PULLING APARTMENT, GUARD RAILS SPLIT AND PULLING AWAY FROM SUPPORTS,WOOD TREADS SPLIT,METAL BRACKETS ON PORCH RUSTED,UPRIGHTS NOT ON CENTER OF PIER BLOCKS,BOTTOM OF UPRIGHTS RUSTED BECAUSE OF METAL BRACKETS. 2219 3ST.PORCH; TREAD WINDER SMAL TREAD CUT IN FRONT,STRINGERS NOT BOLTED TO SUPPORTS,REPLACE 4X4 UPRIGHTS WITH 6X6S,SCAB WOOD ATTACH TO GUARD RAIL WALL SUPPORTS,TREAD WINDERS NOT SUPPORTED PROPERLY. 2221 3ST.PORCH; UPRIGHTS NOT SITTING ON THE CENTER OF PIER BLOCK,6X6S OVERCUT [USING WOOD SHIMS]GTO1ST STRINGER BROKEN AND HAND RAIL LOOSE,STRINGERS SUPPORTED PROPERLY,6X6 UPRIGHT LAP JOINT PULLING APART,GUARD RAILS WOOD SPLIT AND PULLING AWAY FROM SUPPORTS,LANDING WOOD DECK SPLIT AND WEAK,SMALL PIECE OF DECKING USED FOR NOSING,URIGHTS BOWED AND TWISTED,REPLACE 4X4 UPRIGHT WITH 6X6 AND OVERNOTCH,UPRIGHTS NOT SITTING ON CENTER OF PIER BLOCKS.2217 3ST.PORCH; UPRIGHTS OUT OF PLUMB AND OVERNOTCH,STRINGERS NOT SUPPROTED PROPERLY,GUARD RAILS WOOD SPLIT AND PULLING AWAY FROM SUPPORTS,DECKING WOOD SPLIT,REPLACE 4X4 UPRIGHTS WITH 6X6S. 2205 3ST.PORCH; GUARD RAIL WALL SUPPORT NOT BOLTED TO THE WALL,STRINGERS NOT SUPPORTED PROPERTLY,REPLACE 4X4 UPRIGHT WITH 6X6S,METAL BRACKETS RUSTED. 2209 3ST PORCH; TREADS WOOD SPLIT,6X6 UPRIGHT NOT SITTING ON CENTER OF PIER BLOCK AND RUSTED BRACKET,6X6 UPRIGHTS TWISTED AND OVERNOTCH,GUARD RAILS WOOD SPLIT AND PULLING AWAY FROM SUPPORTS,LEDGER BOARD PULLING AWAY FROM THE WALL,OUT SID RIM JOIST OVERCUT,REPLACE 4X4 WITH 6X6S. 2207,2211 3ST.PORCH; UPRIGHTS OVERNOTCH AND BOWED,TREAD WINDERS WEAK,WOOD SHIMS ATTACH TO RIM JOIST,STRINGER NOT BOLTED TO SUPPORTS,4X4 UPRIGHT SITTING ON RIM JOIST FOR STRINGER SUPPORTS,METAL BRACKETS RUSTED. 2213 3ST.PORCH; 6X6 UPRIGHTS BOWED AND TWISTED,UPRIGHT LAP JOINTS PULLING APART,STRINGER DETERIORATING AND SUPPORTED PROPERLY,4X4 POST ROTTED AND WEAK,PICKETS IMPROPER SPACING AND WEAK,GUARD RAILS WOOD SPLIT AND WEAK.[SUBMIT PLANS AND PERMITS FOR REPAIRS] 2221 PORCH;6X6 UPRIGHT OVERCUT[USING WOOD SHIMS],STRINGERS BROKEN,G TO 3RD FLR.STRINGERS NOT SUPPORTED PROPERLY 2569 PORCH;6X6 UPRIGHT TWISTED AND SEPARATING,IMPROPER PICKET SPACING 2213 PORCH;IMPROPER PICKET SPACING,TREAD WINDERS NO SUPPORT AND PULLING AWAY 2215 PORCH;IMPROPER PICKET SPACING,6X6 UPRIGHTS LAP JOINTS SEPARATING 2219 PORCH;IMPROPER PICKET SPACING 2211 PORCH;6X6 UPRIGHT BOWED,IMPROPER PICKET SPACING,GUARD RAILS PULLING AWAY FROM SUPPORTS,STRINGERS NOT BOLTED TO THE WALL 2213 PORCH;STRINGER BROKEN,3RD FL.STRINGER AWAY FROM THE WALL 2213,2211,2219,2217,2215,2213,2569,2221,2573 PORCH SYSTEMS GUARD RAIL SUPPORTS ON THE WALL NOT SUPPORTED PROPERLY.[PERMITS FOR REPAIRS] 2205 N ROCKWELL ST PERIODIC FAILED View
STOP LEAKING WATER LOWER LEVEL SOUTH STORAGE ROOM - LEAKING WATER WITH WATER DAMAGE AND HOLE IN CEILING 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR LINTELS NORTH ELEVATION 2ND AND 3RD FLOOR - LINTELS SEVERELY RUSTED.WEST ELEVATION, 3RD FLOOR AT 2207 AND 2219 - LINTELS SEVERELY RUSTED AND SAGGING WITH VOLUMETRIC EXPANSION. MASONRY PERMIT REQUIRED FOR REPAIRS. SOUTH ELEVATION, 3RD FLOOR LINTEL RUSTED. 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR EXTERIOR WALL NORTH ELEVATION 2ND AND 3RD FLOOR - SOLDIER COURSE ABOVE LINTELS SHIFTING OUT. WEST ELEVATION, 3RD FLOOR AT 2207 AND 2219 - BRICK SHIFTING ABOVE LINTELS - CRACKES IN BRICK BEGINING TO REFORM AT WINDOWS. MASONRY PERMIT REQUIRED FOR REPAIRS. EAST ELEVATION, 1ST AND 2ND FLOORS - STEP FRACTURES IN BRICK ABOVE WINDOWS. SOUTH ELEVATION, 3RD FLOOR AT SOUTHWEST CORNER - STEP FRACTURE IN BRICK. 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR WINDOW SILLS NORTH ELEVATION, WINDOW SILLS CRACKED. 2205 N ROCKWELL ST PERIODIC FAILED View
CHIMNEY EAST ELEVATION, CHIMNEY - MORTAR SPALLING 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR PORCH SYSTEM 2207 REAR PORCH SYSTEM - ROOF LEDGER BOARD - LOOSE BOLTS. 2205 N ROCKWELL ST PERIODIC FAILED View
1HR SEP-D.U. AND REST OF BLDG LOWER LEVEL BIKE ROOM AND SOUTH STORAGE ROOM - HOLES IN CEILING WITH EXPOSED FLOOR JOIST FROM DWELLING UNIT ABOVE. 2205 N ROCKWELL ST PERIODIC FAILED View
CARB MONOX DETECT IN RESID LOWER LEVEL SOUTH BOILER ROOM - MISSING CARBON MONOXIDE DETECTOR. 2205 N ROCKWELL ST PERIODIC FAILED View
H.P 2 HR ENCLOSURE LOWER LEVEL SOUTH BOILER ROOM - PIPE PENETRATIONS MISSING FIRE SEAL MATERIALS. 2205 N ROCKWELL ST PERIODIC FAILED View
INSTALL SMOKE DETECTORS 2215 INTERIOR STAIRWELL - SMOKE DETECTOR MISSING AT TOP OF STAIRWELL. 2205 N ROCKWELL ST PERIODIC FAILED View
RESTORE EXIT AND EM INTERIOR STAIRWELLS AT 2207, 2211, 1115 AND 2219 - MULTIPLE EMERGENCY LIGHTING OUT OF SERVICE. 2205 N ROCKWELL ST PERIODIC FAILED View
SERVICE WALK, PASSAGE, AREAWAY SOUTH ELEVATION, SERVICE WALK CRACKED AND BUCKLING. 2205 N ROCKWELL ST PERIODIC FAILED View
SCREEN OUTER DOORS, WINDOWS REAR EXITS TO PORCHES FROM APARTMENTS ALL LEVELS MISSING SCREEN DOORS . 2205 N ROCKWELL ST PERIODIC FAILED View
CONNECT GAS APPLIANCE TO VENT NORTH BASEMENT BOILER ROOM , WATER HEATER FLUE PIPES BACKPITCHED AND JOGGED AROUND CEILING BEAM . 2205 N ROCKWELL ST PERIODIC FAILED View
PROVIDE PROVIDE PER CODE SECTION 18-27-700.6 EMERGENCY LIGHTING . EMERGENCY LIGHTING MISSING IN BASEMENT BIKE STORAGE ROOM . 2205 N ROCKWELL ST PERIODIC FAILED View
1-HR STAIR ENCLOSURE, <3 STORY 2221 STAIRWAY LANDING CEILING PATCHED WITH NON FIRE RATED PLYWOOD . 2205 N ROCKWELL ST PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY 2209 UNIT #BE - REMOVED KEYED LOCKS FROM EXITPATH DOORS TO REAR EXIT FROM UNIT . 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING 2209 3RD FLOOR STAIRWAY WALL AND CEILING WATER DAMAGED PAINT AND PLASTER . 2205 N ROCKWELL ST PERIODIC FAILED View
CARB MONOX DETECT IN RESID LOWER LEVEL SOUTH BOILER ROOM - MISSING CARBON MONOXIDE DETECTOR. 2205 N ROCKWELL ST PERIODIC FAILED View
INSTALL SMOKE DETECTORS 2215 INTERIOR STAIRWELL - SMOKE DETECTOR MISSING AT TOP OF STAIRWELL. 2205 N ROCKWELL ST PERIODIC FAILED View
SERVICE WALK, PASSAGE, AREAWAY SOUTH ELEVATION, SERVICE WALK CRACKED AND BUCKLING. 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR EXTERIOR WALL WEST ELEVATION / EXTERIOR WALL-BULGING BRICKS ABOVE 3RD FLOOR WINDOWS.PERMIT REQUIRED FOR MASONRY REPAIRS. 2205 N ROCKWELL ST PERIODIC FAILED View
PROTECT SIDEWALK DURING CONST INSTALL PROTECTIVE CANOPY OVER WEST ELEVATION-PUBLIC SIDEWALK WITH CANOPY.PERMIT,ISSUED BY DEPARTMENT OF TRANSPORTATION,REQUIRED FOR SUCH INSTALLATION. 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR PORCH SYSTEM TEN WOOD THREE STORY PORCHES,DECKS STAINED WITH ALL COMPONENTS WORN AND WEATHERED FINISH.SIMILAR DEFECTS THROUGHOUT.UPRIGHTS ARE NOTCHED AND DOUBLE NOTCHED.2X8 UNDER SIZED FLOOR JOISTS OVER SPANED TO 10 FEET AT DECKS AND LANDINGS.HARDWARE BOLTS AND BRACKETS ARE RUSTED.HANDRAILS AND GUARDRAILS ONLY NAILED TO SUPPORTS.LANDING GUARDRAILS OVERSPANNED WITHOUT CENTER SUPPORT POSTS.PICKETS LOOSE AND OVER SPACED.PLANS AND PERMIT REQUIRED FOR REPAIRS. 2205 N ROCKWELL ST PERIODIC FAILED View
CHIMNEY NORTH BASEMENT BOILER ROOM.WEST CHIMNEY-BRICKS MISSING AT WALL OF HOT WATER HEATERS. 2205 N ROCKWELL ST PERIODIC FAILED View
SCREEN OUTER DOORS, WINDOWS REAR EXITS TO PORCHES FROM APARTMENTS ALL LEVELS MISSING SCREEN DOORS . 2205 N ROCKWELL ST PERIODIC FAILED View
CONNECT GAS APPLIANCE TO VENT NORTH BASEMENT BOILER ROOM , WATER HEATER FLUE PIPES BACKPITCHED AND JOGGED AROUND CEILING BEAM . 2205 N ROCKWELL ST PERIODIC FAILED View
1-HR STAIR ENCLOSURE, <3 STORY 2221 STAIRWAY LANDING CEILING PATCHED WITH NON FIRE RATED PLYWOOD . 2205 N ROCKWELL ST PERIODIC FAILED View
ABANDONED REFRIGERATOR 2219/ 3RD FLOOR EXTERIOR PORCH-ABANDONED REFRIGERATOR. 2205 N ROCKWELL ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING / NO ENTRY TO MOST AREAS,UNVERIFIED DETECTORS,CONDITIONS. 2205 N ROCKWELL ST PERIODIC FAILED View
DEBRIS, EXCESSIVE SOUTH BASEMENT LAUNDRY ROOM-EXCESSIVE AMOUNTS OF LINT BEHIND DRYERS. 2205 N ROCKWELL ST PERIODIC FAILED View
PROTECT SIDEWALK DURING CONST INSTALL PROTECTIVE CANOPY OVER WEST ELEVATION-PUBLIC SIDEWALK WITH CANOPY.PERMIT,ISSUED BY DEPARTMENT OF TRANSPORTATION,REQUIRED FOR SUCH INSTALLATION. 2205 N ROCKWELL ST PERIODIC FAILED View
DEBRIS, EXCESSIVE SOUTH BASEMENT LAUNDRY ROOM-EXCESSIVE AMOUNTS OF LINT BEHIND DRYERS. 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING 1 W APT. BATHROOM - WATER DAMAGED WALLS . 2205 N ROCKWELL ST PERIODIC FAILED View
CONNECT GAS APPLIANCE TO VENT NORTH BASEMENT BOILER ROOM , WATER HEATER FLUE PIPES BACKPITCHED AND JOGGED AROUND CEILING BEAM . 2205 N ROCKWELL ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING / NO RESPONSE,UNABLE TO VERIFY SMOKE AND CARBON MONOXIDE ALARMS. 2205 N ROCKWELL ST PERIODIC FAILED View
CHIMNEY NORTH BASEMENT BOILER ROOM.WEST CHIMNEY-BRICKS MISSING AT WALL OF HOT WATER HEATERS. 2205 N ROCKWELL ST PERIODIC FAILED View
ABANDONED REFRIGERATOR 2219/ 3RD FLOOR EXTERIOR PORCH-ABANDONED REFRIGERATOR. 2205 N ROCKWELL ST PERIODIC FAILED View
1-HR STAIR ENCLOSURE, <3 STORY 2221 STAIRWAY LANDING CEILING PATCHED WITH NON FIRE RATED PLYWOOD . 2205 N ROCKWELL ST PERIODIC FAILED View
REPAIR PORCH SYSTEM TEN WOOD THREE STORY PORCHES,DECKS STAINED WITH ALL COMPONENTS WORN AND WEATHERED FINISH.SIMILAR DEFECTS THROUGHOUT.UPRIGHTS ARE NOTCHED AND DOUBLE NOTCHED.2X8 UNDER SIZED FLOOR JOISTS OVER SPANED TO 10 FEET AT DECKS AND LANDINGS.HARDWARE BOLTS AND BRACKETS ARE RUSTED.HANDRAILS AND GUARDRAILS ONLY NAILED TO SUPPORTS.LANDING GUARDRAILS OVERSPANNED WITHOUT CENTER SUPPORT POSTS.PICKETS LOOSE AND OVER SPACED.PLANS AND PERMIT REQUIRED FOR REPAIRS. 2205 N ROCKWELL ST PERIODIC FAILED View
FILE BLDG REGISTRATION REGISTER BUILDING FOR 1990 THRU 2011 2205 N ROCKWELL ST PERIODIC FAILED View
EXT. WALL. FIRE RESISTANCE COVERED AREAWAY CEILINGS AT GRADE 2207 , 2219 AND 2221 NOT FIRE RATED MATERIALS . 2205 N ROCKWELL ST PERIODIC FAILED View
EXT. WALL. FIRE RESISTANCE COVERED AREAWAY CEILINGS AT GRADE 2207 , 2219 AND 2221 NOT FIRE RATED MATERIALS . 2205 N ROCKWELL ST PERIODIC FAILED View